Commisioning
During Daylight
The green LED should be flashing slowly. Depending
upon the battery condition, one of the red LEDs may
also be on.
The luminaire should be on. To check the function of
the luminaire during daytime, cover the solar module
(with cardboard or blanket). After 1 minute the green
LED should become solid, and after a further 4
minutes the luminaire should turn on.
During Night Time
The green LED should be on solid (not flashing).
Depending upon the battery condition, one of the
red LEDs may also be on. The luminaire should be on.
Battery not connected or fuse blown
Normal operation : Night-time detected
Normal operation : Day-time detected
Luminaire fault
Battery low : luminaire brightness reduced
Fault : reconnect in correct sequence
Note: The system takes up to 1 minute to detect the change between
day and night phases, plus an additional 4 minutes for the luminaire to
switch on and off. This is to prevent false day and night detection.
OFF
ON
FLASH
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
FLASH
Maintenance
Battery Pack
The battery pack is expected to last 3 to 4 years, but this depends on installation location. The battery pack can be easily
replaced as follows:
1. Remove the lighting column access cover
2. Disconnect the 2 way plug
3. Disconnect the 3 way plug
4. Remove the fuse from the fuse holder
5. De-couple the bullet crimps from the battery pack
6. Cut the 3 cable ties securing the battery pack in place
7. Refit in the reverse sequence (always fit the fuse before connecting cables)
8. Recheck column ventilation
Solar Panel
The solar module should be periodically inspected for damage. The inspection regime should be set according to prevailing
conditions. Systems installed in areas with significant levels of atmospheric pollutants or excessive wind loads should be
inspected more regularly.
The module is manufactured on anodised, marine grade aluminium to minimise corrosion. Check that the channel clamps are
free from corrosion and that the sign channels are securely fixed to the solar panel.
It is recommended that the front of the module is cleaned during inspection.