TMS Lite LC-18-SQ-4CH Manuale utente

TMS Lite LC-18-SQ-4CH-A1 LIGHTING CONTROLLER UNIT
________________________________________________________
________________________________________________________
LC-18-SQ-4CH
Lighting Controller Unit
(Sequence)
USER MANUAL

TMS Lite LC-18-SQ-4CH-A1 LIGHTING CONTROLLER UNIT
1
Table of Contents
Hardware ................................................................................................................................................2
Packing List..........................................................................................................................................2
General Description ................................................................................................................................3
Specification........................................................................................................................................3
Connectors Description...........................................................................................................................4
Operation Mode .....................................................................................................................................7
Constant Mode ...................................................................................................................................7
Strobe Mode .......................................................................................................................................7
Trigger Mode.......................................................................................................................................8
Current Multiplier ...................................................................................................................................8
LC-18 Software........................................................................................................................................9
Change IP Address.................................................................................................................................11
Slave Board Address Setting .................................................................................................................12
Communication Connection .............................................................................................................13
Input Signal ...........................................................................................................................................14
Output Signal ........................................................................................................................................14
Accessories............................................................................................................................................15
24V Power Supply.............................................................................................................................15
Cable Selection..................................................................................................................................16
Cable Information .................................................................................................................................17
Power Cord Information .......................................................................................................................18
Drawing Dimension...............................................................................................................................19
Communication Protocol ......................................................................................................................20
Revision Notes
Rev
Date/Author
Comment
1.0
Aug2020/KW
First Revision

TMS Lite LC-18-SQ-4CH-A1 LIGHTING CONTROLLER UNIT
2
Hardware
Packing List
Please ensure the following items are in the package:
LC-18-SQ-4CH Controller Package
LC-18-M
LC-18-SQ-4CH-X1
Ethernet Cable x1
RS232 Cable x1
Communication Cable x1set
24V Power Supply (Optional)
Lighting Cable x 16pcs (Optional)
User Manual x1
User Interface (download from the link below)
Link for user interface and user manual from TMS LITE website:

TMS Lite LC-18-SQ-4CH-A1 LIGHTING CONTROLLER UNIT
3
General Description
The LC-18-SQ-4CH-A1 controller provides intensity control of LED lightings for machine
vision applications. The controller consists of 16 channels with individual settings for each
channel. There are 3 modes of operation provided to support different types of application.
Specification
Parameter
Value
Controller Supply Voltage
24 VDC
Lighting Supply Voltage
5/12/24/48 VDC
(According to Lighting Voltage Rating)
No. of Channel
4
Channel Mode
Constant, Strobe, Trigger
Output Current
Maximum 1A per channel
Strobe Delay, Strobe Width,
Output Delay, Output Width
Adjustable 0 –99.99ms (10us/step)
Input Trigger Signal
3.3-24V, >5mA
rising/falling edge trigger
Output Trigger Signal
Support rising/falling edge output trigger
Trigger Delay
≤ 20us
Software Control
RS232 / TCPIP

TMS Lite LC-18-SQ-4CH-A1 LIGHTING CONTROLLER UNIT
4
Connectors Description
Terminal
Function
24V
Controller Power Supply +
0V
Controller Power Supply –
COMM
Communication Port (between master and slave boards)
RS232
RS232 Communication
TCPIP
TCPIP Communication
ADDR
4 Way DIP Switch (for slave address selection)

TMS Lite LC-18-SQ-4CH-A1 LIGHTING CONTROLLER UNIT
5
Terminal
Function
LIGHT INPUT +
Power Supply for Lighting +
LIGHT INPUT –
Power Supply for Lighting –
CH +
Lighting Channel Output +
CH –
Lighting Channel Output –

TMS Lite LC-18-SQ-4CH-A1 LIGHTING CONTROLLER UNIT
6
Terminal
Function
IN +
External Input +
IN –
External Input –
OUT +
External Output +
OUT –
External Output –

TMS Lite LC-18-SQ-4CH-A1 LIGHTING CONTROLLER UNIT
7
Operation Mode
Constant Mode
Constant mode offers continuous lighting intensity control. Lighting intensity is controlled
using constant current technique. Brightness can be adjusted from fully off to fully on in the
range of 0 –255.
Strobe Mode
Strobe mode provides short interval triggering for applications that require high intensity and
high precision. An input trigger signal will turn on the lighting output based on pre-set delay
and duration parameters.
There are 4 adjustable strobe parameters available:
Strobe Delay = Delay time between the external input signal and the lighting output
Strobe Width = Duration of the lighting’s turn on time
Output Delay = Delay time between the external input signal and the external output signal
Output Width = Duration of the external output signal’s turn on time
Parameter timings are in the range of 0-9999 which is equivalent to 0-99.99ms (in step of 10us)
External Trigger
Lighting Strobe
Camera Output
Strobe Delay
Strobe Width
Output Delay
Output Width

TMS Lite LC-18-SQ-4CH-A1 LIGHTING CONTROLLER UNIT
8
Trigger Mode
Trigger mode provides most flexibility for variable timing light output. The light output ON
when input trigger signal received and OFF when no input signal.
Current Multiplier
Current Multiplier setting provides more precise control of lighting intensity for lightings with
different current ratings.
Current Multiplier setting range = 1-10
1 = 10% of max output current (100mA)
2 = 20% of max output current (200mA)
3 = 30% of max output current (300mA)
4 = 40% of max output current (400mA)
5 = 50% of max output current (500mA)
6 = 60% of max output current (600mA)
7 = 70% of max output current (700mA)
8 = 80% of max output current (800mA)
9 = 90% of max output current (900mA)
10 = 100% of max output current (1000mA/1A)
For example: if the lighting’s current rating is 260mA, current multiplier can be set to 3, setting
the maximum output current to 300mA. So the lighting’s intensity can be adjusted from low to
high within the range of 0-255.
If multiplier is set too high, for example 10 (100% of max output = 1A), theadjustable intensity
range for the lighting is only about 0-67. Setting the intensity value to 68 or higher will not
have any effect towards the lighting output brightness.
External Trigger
Lighting Strobe

TMS Lite LC-18-SQ-4CH-A1 LIGHTING CONTROLLER UNIT
9
LC-18 Software
The controller can be controlled using LC-18 software. Connect the controller to computer
with RS232 cable and TCPIP cable.
1. Software Connection :
a. Select COMPORT or TCPIP to connect.
b. Disconnect the software
2. Read and Save function for all slave board :
a. Read all slave board’s parameter from controller.
b. Save all slave board’s parameter into EEPROM.
3. Strobe function for all channel :
a. Strobe all channel once.
b. Repeat strobe all channel (together).
c. Repeat strobe channel by channel.
4. Reset all channel’s parameter to default value.
5. Master board firmware version.
6. Each tab display all the parameters for each slave board.
2
1
3
4
5
6
7
8
9
13
3
10
3
11
3
12
3
14
15
Indice