TOKNAV T10Pro Manuale utente


1. Introduction to the T10Pro 01-03
03-04
05-32
2. PCR100 Data Controller
3. SurPro software operation
32-34
35-38
4. Tilt measurement
5. Host Registration and
Software Licensing

1. Introduction to the T10Pro
1.1. Exterior description
A. Satellite Indicator Light;
B. Power button;
C. 7 Pin data connector (Serial/External Power);
D. SIM card compartment;
E. USB Type C Interface;
F. The loudspeaker hole;
G. UHF Antenna Port.
1.2. Operating Instructions
1.2.1. SIM card installation
Opening the dust plug;
Install the SIM card according to the indication
(SIM card chip is facing up, the notch is facing
the receiver);
Cover with dust plug.
A
C
F
B
E
G
Figure 1 Figure 2
D
01 02

1.2.2. The meaning of the instrument keys
and indicator lights
One flashing light represents
0 to 33% battery level (Figure 4).
Two flashing lights represent 33%
to 66% battery level (Figure 5).
Projects Function Role or status
Battery level broadcast
Switch
Short press to broadcast power
Long press to turn on/off;
Date Chain Light
Rover mode: Blink when receiving
differential data;
Base mode: Blink when sending
differential data;
Satallite Light
Rover/base station: 1 second
interval flashing in the
positioning state;
Static mode: flashing according to
sampling frequency.
1.2.3. Power on and off
1.2.4. Charging equipment
Power on: Press and hold the power button until the voice
prompts "Booting" and release, the device starts up, and
the panel lights flash until the voice prompts "Boot
completed" and the device is turned on.
Shutdown: Press and hold the power button until the
voice prompts "shutdown", the panel lights are all off,
and the device is shut down.
Forced shutdown: When the device cannot be shut down
normally due to an unexpected failure, press and hold the
power button for 10 seconds to power off the device.
The red light of the power supply is always on when
charging, and the green light is always on when charging
is complete.
The host supports MTK PE1.1/2.0 and PD protocol fast
charging. Using a fast charging adapter for charging can
shorten the charging time.
Note: For the safety of your device, please use the
standard adapter in the package, or a brand adapter that
complies with 3C certification to charge the host.
Note: In the off state, short press the power button, and the
power information can be calculated according to the
number of lights on.
Three flashing lights represent 66%
to 100% battery level (Figure 6).
Figure 3
Figure 4
Figure 5
Figure 6
01 02

with measuring handbook software. T10pro has profes-
sional IP68 grade protection, which is suitable for harsh
outdoor environments. The large-capacity lithium battery
can guarantee more than 10 hours of field work and
complete multiple measurement tasks throughout the
day (Figure 8).
1.2.5. WEB access
The receiver supports Web access to the built-in page for
viewing host information and upgrading firmware. The
host's WIFI hotspot is turned on by default, and the
hotspot name is the machine number SN. Users can
access the hotspot with mobile phones, tablets, PCs and
other devices, and then enter the URL: 10.10.10.10 in the
browser to access the receiver Web UI. As shown in
Figure 7.
Octa-core 2.0GHz CPU;
4GB RAM + 64GB ROM;
5 megapixel front + 13 megapixel rear camera;
IP68 protection, waterproof/shockproof/dustproof;
Wi-Fi, Bluetooth, NFC;
4G all-network support;
7000 mAh battery with 14 hours of battery life;
Universal Type-C connector;
Charging time: less than 4 hours (fast charging).
2. PCR100 Data Controller
The PCR100 TD-LTE wireless computer is a rugged,
multi-function wireless computer designed with a 5-inch
sunlight readable HD touch screen and alphanumeric
keypad, equipped with a powerful octa-core processor
and Android operating system for perfect adaptability
2.1 Overview
2.2 Key features
Figure 7
Figure 8
03 04

You can also connect the T10Pro through the NFC
function of the mobile phone, put the NFC area of the
mobile phone close to the (Figure 11), and in the
pop-up window, click OK to connect (Figure 12).
Run the SurPro measurement software, execute [Config-
device type, as shown in Figure 10, click [Search for
Bluetooth devices], find the Bluetooth name of the
corresponding device in the Bluetooth device list (the
default is the host machine number), click [Start Connect].
The connection progress box will pop up, indicating that
the connection is in progress, and after the connection is
successful, it will prompt that the connection is successful.
3. SurPro software operation
3.1 Connecting equipment
Figure 9 Figure 10 Figure 12
Figure 11
05 06

new project, enter the project name, others are additional
information, which can be left blank, or filled in according
to the actual data, and click [OK] (Figure 14). Jump to the
coordinate system parameter interface. In China, the
ellipsoid parameters are CGCS2000 by default, and the
projection method is Gaussian projection.
You can set the coordinate system for other parameters
according to the actual operation requirements.
3.2 New Project
Copy the data files to be imported to the SurPro Survey
select the corresponding file format and angle format to
import (Figure 15,16 ).
3.3 File import
Figure 15 Figure 16Figure 13 Figure 14
07 08

angle format and file format, then click [Export]. Then we
select the output file storage path, and click [Export], the
data file is exported successfully (Figure 17, 18).
3.4 Document export
Figure 17 Figure 18
Example: four-parameter conversion.
3.5.1 Correctly configure the mobile station to obtain a
fixed state, click [Collect Point] to measure two known
3.5 Parameter conversion
The control point
North: 2562983.7364
East:441751.8702
Height:18.6503
Figure 19
09 10

click the […] button in the lower right corner, select
[Calculate Option] in the pop-up window (Figure 21), and
set the parameter settings (Figure 22).
Figure 20 Figure 21 Figure 22
measurement points from the point library (Figure 24),
and add two sets of data. Then click Calculate Four
Parameters(Figure 25), scroll down the parameter report
page, as shown in the frame, the scale should be infinitely
close to 1. After checking, click [Apply] to apply the
coordinate transformation parameter results to the
project (Figure 26).
3.5.3 Return to the previous page, click [Add] in the lower
left corner (Figure 23), input the coordinates of the known
control points in the local coordinate system, perform
point measurement in the geodetic coordinates of the
source coordinate system or select the coordinates of the
the control point
the collect point
Figure 23 Figure 24
11 12

-
ter calculate] below (Figure 27). Enter the known plane
coordinates, and click on the geodetic coordinates for
more acquisition methods, which include "positioning
acquisition" and "point library acquisition", after the input
is completed, click [Cal.] (Figure 28). After the calculation
is completed, click [OK] to enable the base station transla-
3.6 Point Calibration
Figure 27 Figure 28 Figure 29
Note: In the parameter report, the plane conversion
parameters and elevation conversion parameters can be
checked.
The scale parameter is generally infinitely close to 1. If the
value does not match, please check the operation
whether there is any operation error or coordinate error
in the process.
Figure 25 Figure 26
13 14
Altri manuali per T10Pro
1
Indice
Altri manuali TOKNAV Ricevitore