Tomahawk TG5500i Manuale utente

TG5500i
INVERTER GENERATOR Operations Manual
FIND THE HOW TO GUIDE ON


Thank you for choosing a Tomahawk Generator!
Please read this manual carefully before operating. Safely and
correctly operating your generator will ensure you get the best
results.
All information in this publication is based on the latest
product information available at the time of printing. The contents
in this manual may be different from the actual parts due to revision
and other changes.
Tomahawk Power, LLC reserves the right to make changes at
any time without notice and without incurring any obligation. No
part of this publication may be reproduced without written
permission from Tomahawk Power, LLC.
This manual should be considered a permanent part of the
generator and should remain with the generator if it is resold.

SAFETY
Your safety and the safety of others are very important. We have
provided important safety information in this manual and on the
generator. Please read these messages carefully.
A safety message alerts you to potential hazards that could hurt
you or others. Each safety message is preceded by a safety alert
symbol and one of three words: DANGER, WARNING, or
CAUTION:
You WILL be KILLED or SERIOUSLY HURT if you do not follow
instructions.
You CAN be KILLED or SERIOUSLY HURT if you do not follow
instructions.
You CAN be SERIOUSLY HURT if you do not follow instructions.
Your generator or other property could be DAMAGED if you do not
follow instructions.

CONTENTS
GENERATOR......................................................................................... 1
SAFETY MESSAGES............................................................................ 3
1. SAFETY NOTICE............................................................................... 5
1. Safety Standard......................................................................... 5
2. Special Requirements................................................................ 6
2.COMPONENT IDENTIFICATION........................................................ 7
1. Component Identification ........................................................... 7
2. Engine Type & Serial Number.................................................... 8
3. CONTROLFUNCTION....................................................................... 9
1. Oil warning light (red)................................................................. 9
2. Overload indicator light (Red) .................................................... 9
4. PREPARATION................................................................................ 11
1. Fuel.......................................................................................... 11
2 Engine oil.................................................................................. 11
3. Recoil Starter........................................................................... 12
4. Fuel Valve................................................................................ 12
5. AC Circuit Breaker/Over current Protector............................... 12
6. Ground
Terminal........................................................................ 13
5. GENERATOR OPERATION ............................................................ 14
1. Connection to the Household Power Supply............................ 14
2.
Generator
Grounding.................................................................. 15
3.ACCurrent................................................................................. 15
4. DC Current............................................................................... 16
5. High Altitude Operation............................................................ 16
6. STARTING THE ENGINE................................................................ 17
1. Recoil Starter........................................................................... 17
2. Electric starting ........................................................................ 18
7. STOPPING THE ENGINE................................................................ 18
8. MAINTENANCE............................................................................... 19
1. Engine Oil Change................................................................... 20
2. Air Cleaner Service.................................................................. 21
3. Fuel Sediment Cup Cleaning................................................... 22
4. Spark Plug Service .................................................................. 23
9. STORAGE........................................................................................ 23
10. TROUBLESHOOTING................................................................... 25
11. WIRING DIAGRAM........................................................................ 26
12. SPECIFICATIONS ......................................................................... 27

1. SAFETY NOTICE
1. Safety Standard
Read and understand this owner’s manual before
operating your generator. You can help prevent accidents
by being familiar with your generator’s controls, and by
observing safe operating procedures.
DO NOT operate indoors
DO NOT operate in the wet
conditions
DO NOT directly connect to a
household power supply
DO NOT smoke when refueling

DO NOT overflow the fuel
when refueling
Stop the engine before refueling
Keep the generator at least 10 feet far away from any
flammable materials
2. Special Requirements
Electrical equipment including lines and plug connections
should not be damaged in any way or have exposed wires.
The circuit breakers that have been installed match with the
provided generator.
If the circuit breakers require replacement, the replacement
must be a circuit breaker with identical ratings and
performance characteristics.
DO NOT operate the generator before grounding.

If using extension cords, be sure to check the electrical needs
of your appliance, as electrical power is lost over distance. Use
this rule: if your extension cord is #16 gauge wire,
you can have a cord up to 50 feet. For the same appliance,
if your cord is #10 gauge, your maximum length is 250 feet.
2.COMPONENT IDENTIFICATION
1. Component Identification
TG5500i

2. Engine Type & Serial Number

3. CONTROL FUNCTION
1. Oil warning light (red)
When the oil level falls below the
required level, the oil warning light
will turn on and the engine will stop
automatically. Unless you refill with
oil, the engine will not start again.
Tip: If the engine stalls or does not
start, turn the engine switch to “ON”
and then pull the recoil starter.
If the oil warning light flickers for a few seconds,
the engine oil is insufficient. Add oil and restart.
2. Overload indicator light (Red)
The overload indicator light comes on
when an overload of a connected
electrical device is detected, the
inverter control unit overheats, or the
AC output voltage rises. Then, the AC
protector will trip, stopping power
generation to protect the generator and any connected
electrical devices. The AC pilot light (Green) will go off and the
overload indicator light (Red) will stay on, but the engine will
not stop running.
When the overload indicator light comes on and power
generation stops, proceed as follows:
1)Turn off any connectedelectrical devices and stop the
engine.
2)Reduce the total wattage of connected electrical
devices within the rated output.
3)Check for blockages in the cooling air inlet and around