Trainer NF1200-T Manuale utente

i-PAD NF1200-T
Operator’s Manual
AED Trainer

2CU Medical Systems, Inc.
NF1200-T
Table of Contents ·············································································································· 2
1. Introduction ·················································································································· 3
Product Description ·············································································································· 3
Intended Use···················································································································· 3
2. Device Orientation········································································································· 4
3. Setting up the i-PAD ······································································································ 8
Package Contents ············································································································· 8
Infrared Remote Controller (Remocon) ················································································ 9
Rescue Scenarios ············································································································ 11
Setting up the i-PAD NF1200-T ························································································· 14
4. Using the i-PAD NF1200-T ··························································································· 15
Simulated Rescue Preparation··························································································· 15
Simulated Main Rescue Sequence ····················································································· 18
5. Servicing the i-PAD NF1200-T ····················································································· 23
Warranty ······················································································································· 23
Warranty Disclaimer ········································································································ 23
Service ·························································································································· 24
How to Contact Us ·········································································································· 25
Table of Contents

3
Operator’s Manual Ver 1.30
The charging and shock delivery operations of the i-PAD NF1200-T are simulated
only. The device does not contain any defibrillating capacitor and thus it can not
deliver a real defibrillating shock.
NOTICE
1. Introduction
Product Description
The i-PAD NF1200-T is a defibrillator simulator designed to mimic the operations of the i-PAD
NF1200. It can simulate functions of the i-PAD NF1200 such as charging and shock delivery.
It has preprogrammed rescue scenarios that are in accordance with the recommended rescue
protocol of international rescue policy making bodies such as the American Heart Association, the
European Resuscitation Council, and the American Red Cross.
It is to be used in conjunction with the resuscitation mannequin from CU Medical Systems, Inc.
It has a standard infrared remote control accessory which renders it operable by an instructor from
a distance.
Intended Use
The i-PAD NF1200-T is intended for use during Advanced Cardiac Life Support training, Basic Life
Support training, or any other physician approved trainings that deal with the operation of an
automated external defibrillator.
The i-PAD NF1200-T is not intended for use during actual rescue operations as it can not deliver a
defibrillating shock.

2. Device Orientation
NF1200-T
4CU Medical Systems, Inc.
State LED
Power
ON/OFF
button
Remote
control
sensor
i-ButtonHandle
Cover
Turn
ON
First
1
ON/OFF
Then Open
1
Turn
ON
2
Top View of the i-PAD NF1200-T with its cover closed
•

Power ON/OFF
Button Press this button to turn the i-PAD NF1200-T ON or OFF.
i-Button
This button may be used to change the compression-ventilation ratio.
When no pads are attached, entering administration mode by pressing
this button is disabled in this version of the i-PAD NF1200-T.
State LED
Indicates the status of the i-PAD NF1200-T
• blinking green: the i-PAD NF1200-T is in standby mode and ready
for a rescue operation
• solid green: the i-PAD NF1200-T is in rescue mode.
• blinking red: the i-PAD NF1200-T detected a system error or low
battery level during a self-test.
• solid blue: the i-PAD NF1200-T is conducting a self-test.
Operator’s Manual Ver 1.30
5
Shock Button
IrDA (Communication) Port
Battery Pack
Cover
AED Electrode Pads
Connector Port
Quick Reference
Guide
Graphical Rescue
Guide
Perspective view of the i-PAD NF1200-T with its cover open
•

Handle An easy-grip carrying handle for increased portability of the i-PAD
NF1200-T.
Cover Covers the front panel of the i-PAD NF1200-T and retains the
defibrillator electrode pads package.
SHOCK button
Press this button when the i-PAD NF1200-T prompts you to “Press
the flashing orange button now”.
Pressing this button delivers a simulated defibrillation shock to the
manikin.
AED electrode pads
connector port Plug the connector of the AED electrode pads into this port
Graphical Rescue
Guide
Guides you by indicating the current step in the simulated rescue
process.
Quick Reference
Guide
A printed card that summarizes the steps of a simulated rescue
process using the i-PAD NF1200-T.
Battery Pack Provides power to the i-PAD NF1200-T.
IrDA
Communication
Port
This port is disabled in this version of the i-PAD NF1200-T.
Remote Control
Sensor
Senses the infrared control signal from the remote controller. Point
the remote controller at this sensor when you want to control the
i-PAD NF1200-T.
NF1200-T
6CU Medical Systems, Inc.

Operator’s Manual Ver 1.30
7
Do not store the device in
areas with highly fluctuating
temperatures.
Do not store the device
in areas that are directly
exposed to sunlight.
Do not operate or store the
device in conditions that are
beyond the following specified
limits.
Standby conditions
Temperature: 0 °C to 43 °C (32 °F to 109 °F)
Humidity: 5 % to 95 % (non - condensing)
Operating Conditions
Temperature: 0 °C to 40 °C (32 °F to 104 °F)
Humidity: 5 % to 95 % (non - condensing)
Storage Conditions
Temperature: -20 °C to 60 °C (-4 °F to 140 °F)
Humidity: 5 % to 95 % (non - condensing)
Do not store the device
near heating equipment.
Do not install or store in
environments where humidity
tends to rapidly increase or
there is a ventilation problem.
Do not store the device in
areas where there is high
vibration
(in excess of Category 10
of MIL-STD-810E).
Do not operate or store
the device in environments
with high concentration of
flammable gas or anesthetics.
Do not operate or store
the device in areas with
high concentration of dust.
Only personnel authorized by
the manufacturer may open
the device for servicing.
There are no user serviceable
components inside the device.
For product installation and storage, be sure to refer to the following instructions and avoid damage
to the product.

3. Setting up the i-PAD NF1200-T
Package Contents
The i-PAD packaging box contains the following items.
NF1200-T
8CU Medical Systems, Inc.
Tu rn
ON
First
1
ON/OFF
Then Open
1
Tu rn
ON
2
i-PAD NF1200-T
Disposable, non-rechargeable
battery pack
Rechargeable battery pack (option)
Battery Charger (option) Infrared Remote Controller
Trainer Pads
Operator’s Manual

Infrared Remote Controller (Remocon)
This enables an instructor to control the i-PAD NF1200-T from a maximum distance of 3 meters. The
Remote Controller should be pointed at the remote controller sensor of the i-PAD NF1200-T when
controlling its operation.
The instructor should control the i-PAD NF1200-T using this Remote Controller only. Any changes in
simulated ECG and training scenario should be done using this Remote Controller.
Infrared Remote Controller
Operator’s Manual Ver 1.30
9

Infrared Remote Controller Functions
Key Function
POWER OFF Turns the power of the i-PAD NF1200-T OFF when pressed while the
i-PAD NF1200-T is ON.
PAD ON/OFF
Simulates pads ON and pads OFF conditions. Toggles between the
said two conditions when pressed (i.e. if the pads are ON, turns OFF
the pads when pressed; if the pads are OFF, turns ON the pads when
pressed).
After the trainee attaches the pads to the manikin, pressing this button
simulates the attachment of the pads and starts rescue scenario 1.
LOW BAT Simulates a low battery condition when pressed.
UP Increases the level of audio volume when pressed.
DOWN Decreases the level of audio volume when pressed.
S1 to S8
Rescue scenarios 1 to 8. The rescue scenarios simulate rescue
conditions in the field. The trainee may react to the scenarios by doing
the appropriate actions. Only scenarios 1 to 8 are implemented on this
version of the i-PAD NF1200-T
NF1200-T
10 CU Medical Systems, Inc.
Indice