Outdoor Mobility Point Quick Start Guide v.7.1

Outdoor Mobility Point Quick Start Guide v.7.1
2
Trapeze Networks
This guide provides basic hardware installation instructions for MP access point models MP-620,
MP-622, and MP-632. The MP-620, MP-622, and MP-632 are suitable for installation outdoors.
Warning! Installation must be performed by qualified service personnel only. Read and
follow all warning notices and instructions marked on the product or included in the
documentation. Before installing the product, read the rest of this document.
Waarschuwing! De installatie mag alleen worden uitgevoerd door bevoegd
onderhoudspersoneel. Het is essentieel dat u kennis neemt van alle waarschuwingen en
instructies aangebracht op het product zelf en/of opgenomen in de documentatie.
Voordat u het product installeert, dient u dit document in zijn geheel te hebben gelezen.
Warnung! Die Installation darf nur von qualifiziertem Servicepersonal vorgenommen
werden. Lesen und befolgen Sie alle Warnhinweise und -anleitungen auf dem Produkt
bzw. in der Dokumentation. Lesen Sie vor Installation des Produkts den restlichen Teil
dieses Dokuments.
Avertissement! L’installation ne peut être effectuée que par un personnel qualifié.
Lisez et suivez tous les messages d’avertissement et les instructions inscrits sur le
produit ou inclus dans la documentation. Avant d’installer le produit, lisez le reste de ce
document.
Attenzione! L’installazione deve essere effettuata unicamente da personale
qualificato. Leggere e rispettare tutte le segnalazioni di attenzione e le istruzioni
indicate sul prodotto o incluse nella documentazione. Prima d’installare il prodotto,
leggere tutto il documento.
¡Advertencia! La instalación debe realizarse exclusivamente por parte de personal de
servicio cualificado. Lea y siga todas las notas de advertencia e instrucciones en el
producto o la documentación. Antes de instalar el producto deberá leer la parte restante
del presente documento.

Outdoor Mobility Point Quick Start Guide v.7.1 3
Trapeze Networks
¡Advertencia! A instalação dever ser realizada exclusivamente por pessoal de serviço
qualificado. Leia e siga todas as notas de advertência e instrucões no produto ou na
documentação. Antes de instalar o produto deverá ler a parte restante do presente
documento.
Varning! Installation får endast utföras av kvalificerad servicepersonal. Läs och följ
alla varningsmeddelanden och instruktioner markerade på produkten eller inkluderade
i dokumenteringen. Innan produkten installeras skall resten av dessa dokument läsas.
Advarsel! Installation må kun gennemføres af faglært servicepersonale. Læs, og følg
alle de advarselsmeddelelser og anvisninger, der er anført på produktet eller i
dokumentationen. Læs resten af dette dokument før installation af produktet.
Advarsel! Installasjon skal kun utføres av kvalifisert service personell. Les og følg alle
varsels meldinger og instrukssjons merkinger på produktet og i veiledningen. Les
resten av denne veiledningen før produktet installeres.
Varoitus! Installatie dient uitsluitend plaats te vinden door bevoegde monteurs. Lees
alle waarschuwingen en instructies die op het product zijn aangegeven of in de
documentatie zijn opgenomen, en volg deze op. Lees voordat u het product installeert
eerst de rest van dit document.
Viðvörun! Aðeins hæfir þjónustufulltrúar mega sinna uppsetningu tækjanna. Lesið og
fylgið öllum viðvörunum og leiðbeiningum í þessum gögnum. Lesið restina af þessum
gögnum fyrir uppsetningu.

Outdoor Mobility Point Quick Start Guide v.7.1
4
Trapeze Networks

Outdoor Mobility Point Quick Start Guide v.7.1 5
Trapeze Networks
For more information about MP installation as well as safety and installation requirements, see the
following:
❑Outdoor Mobility Point Installation Guide v.7.1
❑For detailed compliance information see the Trapeze Regulatory Guide located at:
http://www.trapezenetworks.com/support/contact_support/. The guide can be downloaded
in PDF format.
MP-620
The MP-620 provides wireless access point services for clients in the local LAN area, and can provide
point-to-point or point-to-multipoint wireless bridge links between remote Ethernet LANs. The MP is
housed in a weatherproof enclosure for mounting outdoors and includes brackets for attaching to a
wall, pole, radio mast, or tower structure. The unit is powered through an Ethernet cable connection
from a power injector module installed indoors. The MP-620 provides a 54 Mbps half-duplex
connection for each active channel.
A wireless bridge system offers a solution for connectivity between remote Ethernet wired LANs, or to
provide Internet access to an isolated site where a wired link may be difficult or expensive to deploy.
The wireless bridge connection provides data rates of up to 108 Mbps.
Radio Characteristics – The IEEE 802.11a and 802.11g standards use a radio modulation
technique known as Orthogonal Frequency Division Multiplexing (OFDM), and a shared collision
domain (CSMA/CA). The 802.11a standard operates in the 5 GHz Unlicensed National Information
Infrastructure (UNII) band, and the 802.11g standard in the 2.4 GHz band.
IEEE 802.11g includes backward compatibility with the IEEE 802.11b standard. IEEE 802.11b also
operates at 2.4 GHz, but uses Direct Sequence Spread Spectrum (DSSS) and Complementary Code
Keying (CCK) modulation technology to achieve a communication rate of up to 11 Mbps.
MP-622
The MP-622 provides only external antenna options and is designed to operate as the “root bridge” in
point-to-multipoint configurations, supporting wireless bridge connections to as many as six units.
The MP is housed in a weatherproof enclosure for mounting outdoors and includes brackets for
attaching to a wall, pole, radio mast, or tower structure. The unit is powered through an Ethernet
cable connection from a power injector module installed indoors. The wireless bridge connection
provides data rates of up to 54 Mbps.
MP-632
The MP-632 is a 802.11a/b/g/n outdoor AP that is designed for pole-mounting and wall mounting. The
MP-632 supports 6 antenna ports, three for the 11a/n radio and three for the 11b/g/n radio. An MX
cannot be used to power the outdoor AP. An XPS-6201-OUT or XPS-6202-OUT outdoor power supply
that uses the IP67 multi-pin DIN connector is required. The MP-632 supports a new set of external
antennas that are commercially available. The MP-632 does not support internal antennas or PoE
The MP-632 must only be used with a Trapeze-approved XPS-6201-OUT or
XPS-6202-OUT outdoor power supply in order to prevent possible damage to the unit.

Outdoor Mobility Point Quick Start Guide v.7.1
6
Trapeze Networks
Package Checklist
The MP-620 package includes:
❑One MP-620 Mobility Point (MP)
❑One Category 5 network cable, length 164 ft (50 m)
❑One power injector module and power cord
❑Outdoor pole-mounting bracket kit
❑Installation manual
❑Optional: Two N-type RF coaxial cables
❑Optional: Outdoor wall-mounting bracket kit
❑Optional: Lightning protector for outdoor antenna
The MP-622 package includes:
❑One MP-622 Mobility Point (MP)
❑XPS-6201-OUT or XPS-6202-OUT (packaged in a separate box)
❑Installation manual
❑Optional: Lightning protector for outdoor antenna
The MP-632 package includes:
❑One MP-632 Mobility Point (MP)
❑Mounting brackets and mounting hardware
❑Weather sealing caps for all 6 external antenna connectors
❑Installation manual
❑Separate package for XPS-6201-OUT or XPS-6202-OUT outdoor power supply (orderable option).
❑Circular DIN to RJ45 dongle cable and waterproof caps for RJ45 dongle
❑Two-hole tabular lug for AWG #8 ground cable
❑Antenna connector terminator. Any unused antenna connector on an active radio must be
terminated.
Contact Trapeze Networks if there are any incorrect, missing or damaged parts. If possible, retain
the carton, including the original packing materials. Use them again to repack the product in case
there is a need to return it.

Outdoor Mobility Point Quick Start Guide v.7.1 7
Trapeze Networks
Installing and Connecting an Outdoor MP
Installation Requirements and Recommendations
For best results, follow these requirements and recommendations before installing an MP-620,
MP-622, or MP-632.
RingMaster Network Plan and Work Orders
If you are using RingMaster to plan your Trapeze Networks Mobility System installation, you might
want to create and verify a network plan for the entire Trapeze network installation and generate an
MP work order, before installing MP access points. A network plan and the MP work orders
generated from it provide the following information about MP access point installation and
configuration:
❑Number of MP access points required for adequate WLAN capacity in each coverage area
❑Detailed installation location for each MP access point
❑Settings for all MP access points in the WLAN
MX Appliance Recommendation
Trapeze Networks recommends that you install and configure the MX before installing an MP. If the
MX is already installed and configured for the MPs, you can immediately verify the cable
connection(s) when you plug the cable(s) into the MP.
Weather Conditions
When planning an MP-620, MP-622, or MP-632 installation, you must take into account any extreme
weather conditions that are known to affect your location. Consider the following factors:
Temperature
Operating an MP in temperatures outside of the supported range may cause the unit to fail.
❑The MP-620 is tested for normal operation in temperatures from -33°C to 55°C.
❑The MP-622 is tested for normal operation in temperatures from -30° to 55 °C (-22° to
131°F).
❑The MP-632 is tested for an ambient operating temperature range of -40°C to +55°C.
Before installing an MP access point, you might need to generate a network plan and
an MP work order with RingMaster. (See RingMaster Network Plan and Work
Orders below.)
MP models MP-620,MP-622 and MP-632 are designed to receive power only from a
Trapeze-provided power injector.

Outdoor Mobility Point Quick Start Guide v.7.1
8
Trapeze Networks
Wind Velocity
You must consider the known maximum wind velocity and direction at the site and be sure that
any supporting structure, such as a pole, mast, or tower, is built to withstand this force.
❑The MP-620, MP-622, and MP-632 can operate in winds up to 90 MPH and survive higher
wind speeds up to 125 MPH.
Lightning
The MP-620, MP-622, and MP-632 both include built-in lightning protection. However, you should
make sure that the unit, any supporting structure, and cables are all properly grounded. Additional
protection using lightning rods, lightning arrestors, or surge suppressors may also be employed.
Rain
❑The MP-620 and MP-622 units are weatherproofed against rain. Also, prolonged heavy rain
has no significant effect on the radio signal. However, it is recommended to apply
weatherproof sealing tape around the Ethernet port and antenna connectors for extra
protection. If moisture enters a connector, it may cause a degradation in performance.
❑The MP-632 weatherproof enclosure is designed to protect against dust, rain, and water jets.
Snow and Ice
❑Falling snow, like rain, has no significant effect on the radio signal. However, a build up of
snow or ice on antennas may cause a degradation in performance. In this case, the snow or ice
has to be cleared from the antennas to restore proper operation of the unit.
Ethernet Cabling
When you have determined a suitable location for the MP-620, MP-622, or MP-632, you must plan a
cable route from the MP outdoors to the power injector module indoors. Consider these points:
❑The Ethernet cable length should never be longer than 328 ft (100 m) over CAT5, CAT5e, or CAT6
cable.
❑Determine a building entry point for the cable.
❑Determine if conduits, bracing, or other structures are required for safety or protection of the cable.
❑For lightning protection at the power injector end of the cable, consider using a lightning arrestor
immediately before the cable enters the building.
Grounding
MP-620, MP-622, and MP-632
❑It is important that the MP-620, MP-622 and MP-632 units, cables, lightning arrestors, and any
supporting structures are properly grounded. The MP-620 and MP-622 units include a grounding
screw for attaching a ground wire. Be sure that grounding is available and that it meets local and
national electrical codes. The MP-632 includes two grounding screws and a tubular lug for
attaching a crimped ground wire.
See the Outdoor Power Supply Installation Guide for details on installing the power
supply for the MP-620.

Outdoor Mobility Point Quick Start Guide v.7.1 9
Trapeze Networks
MP Radio Safety Advisories
When you enable the MP radio(s) as part of MX configuration, the radios are able to receive and
transmit radio frequency energy as soon as you connect the MP to the MX, either directly or through
the network.
Radio Frequency Exposure
Federal Communications Commission (FCC) Docket 96-8 for Spread Spectrum Transmitters specifies
a safety standard for human exposure to radio frequency electromagnetic energy emitted by
FCC-certified equipment. When used with the proper antennas (shipped in the product), Trapeze
Networks MP access point products meet the uncontrolled environmental limits found in OET-65 and
ANSI C95.1-1991. Proper installation of the MP access point according to the instructions in this
manual will result in user exposure that is below the FCC recommended limits.
Additional Radio Safety Advisories
For additional radio safety warnings, the Regulatory Guide document.
Installing an MP-620
The MP-620 includes a bracket kit for mounting the unit to a 1.5 to 2 inch diameter steel pole or tube.
The pole-mounting bracket allows the unit to be mounted to part of a radio mast or tower structure.
The unit also has a wall-mounting bracket kit that enables it to be installed on a building wall or roof
when using external antennas.
Hardware installation of the MP-620 involves these steps:
1. Mount the unit on a wall, pole, mast, or tower using the mounting bracket.
2. Mount external antennas on the same supporting structure as the MP-620 and connect them to
the unit.
3. Connect the Ethernet cable and a grounding wire to the unit.
4. Connect the power injector to the Ethernet cable, a local LAN switch, and an AC power source.
5. For wireless bridge or Mesh Services installations, align antennas at the bridge or mesh link
endpoints.
Mounting the Unit
You can mount the MP-620 using either the pole-mounting bracket or the wall-mounting bracket. Use
one of the following procedures.
Using the Pole-Mounting Bracket
Perform the following steps to mount the unit to a 1.5 to 2 inch diameter steel pole or tube using the
mounting bracket:
1. Always attach the bracket to a pole with the open end of the mounting grooves facing up.
If you are installing the MP-620 as a Mesh AP in a WLAN Mesh or wireless bridge
configuration, and the MP will not have a wired link to an MX , you must configure
the MP connection using a wired link to an MX switch before deploying the MP-620
in a final location.
See the Mobility System Software Configuration Guide for information about
configuring WLAN Mesh Services and wireless bridging.

Outdoor Mobility Point Quick Start Guide v.7.1
10
Trapeze Networks
2. Place the U-shaped part of the bracket around the pole and tighten the securing nut just enough
to hold the bracket to the pole. (The bracket may need to be rotated around the pole during the
alignment process.)
Figure 1–1. Attaching the Bracket to the Pole
3. Use the included nuts to tightly secure the MP-620 to the bracket.
Mounting on Larger Diameter Poles
In addition, there is a method for attaching the pole-mounting bracket to a pole that is 2 to 5 inches in
diameter using an adjustable steel band strap (not included in the kit). A steel band strap up to 0.5
inch (1.27 cm) wide can be threaded through the main part of the bracket to secure it to a larger
diameter pole without using the U-shaped part of the bracket. This method is illustrated in the
following figure.
Figure 1–2. Attaching the Bracket Using a Steel Band Strap
Using the Wall-Mounting Bracket
Perform the following steps to mount the unit to a wall using the wall-mounting bracket:
1. Always attach the bracket to a wall with the open end of the mounting grooves facing up (see
following figure).
A
ttach bracket to
pole with mounting
grooves facing up
Steel Band Clamp
Altri manuali per Mobility Point MP-620
2
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Trapeze Punto di accesso wireless

Trapeze
Trapeze Mobility Point MP-620 Manuale utente

Trapeze
Trapeze Indoor Mobility Point Manuale utente

Trapeze
Trapeze Mobility Point MP-372 Manuale utente

Trapeze
Trapeze Mobility Point Series Manuale utente

Trapeze
Trapeze Mobility Point MP-620 Manuale utente

Trapeze
Trapeze MP-82 Manuale utente

Trapeze
Trapeze Mobility Point MP-122 Manuale utente