Trikdis RL14 Manuale utente

www.trikdis.com UAB Trikdis Draugystės str. 17, LT-51229 Kaunas, Lithuania +370 37 408 040 [email protected]
IP/SMS receiver RL14
User manual v220127
January, 2022

User Manual v220127
IP/SMS receiver RL14
www.trikdis.com 2 January, 2022
Contents
I. Safety requirements .................................................................................................................................. 3
II. Warranty .................................................................................................................................................... 3
III. About receiver ........................................................................................................................................... 4
IV. Receiver functionality ................................................................................................................................ 4
V. Technical parameters ................................................................................................................................ 5
VI. Equipment ................................................................................................................................................. 5
VII. Receiver elements ................................................................................................................................. 6
A. Front view and light indication. ............................................................................................................... 6
B. Rear view and rear panel elements. ........................................................................................................ 6
VIII. Preparing the receiver for operation .................................................................................................... 7
IX. Configuring the receiver ............................................................................................................................ 9
A. Connecting to a new receiver and setting LAN addresses. ..................................................................... 9
B. Connecting to a receiver operating in LAN. ........................................................................................... 10
C. Configuring remote server IP address for communication channel testing, receiver sound signals and
clock (tab Configure). ............................................................................................................................. 12
D. List of receiver events. Disabling generation of event messages (tab Events). ..................................... 12
E. Controlling communication with GPRS and GSM objects (tab General). .............................................. 13
F. Setting operation mode of COM ports (tab COM settings). .................................................................. 13
G. SMS messages using SMPP protocol (tab SMPP settings). .................................................................... 14
H. Adding receivers and setting their parameters (tab Receivers). ........................................................... 14
I. Directing messages to the message monitoring software (tab Outputs). ............................................. 15
J. Message filtering (tab Filter). ................................................................................................................. 16
K. User permissions (tab Users). ................................................................................................................ 17
X. Resetting default parameters .................................................................................................................. 19
XI. Receiver event messages ........................................................................................................................ 19
XII. License activation ................................................................................................................................ 22

User Manual v220127
IP/SMS receiver RL14
www.trikdis.com 3 January, 2022
I. Safety requirements
IP/SMS receiver RL14 is an electrical device, therefore it may only be installed by qualified specialists
following this manual.
IP/SMS receiver RL14 must be operated following this manual.
II. Warranty
According to the user manual of the receiver and general regulations for installing electrical equipment,
the manufacturer provides a 24-month warranty to the installed and operated product. Warranty coverage
starts at the moment of the product sale and purchase agreement, i.e. date of issue of invoice or fiscal receipt.

User Manual v220127
IP/SMS receiver RL14
www.trikdis.com 4 January, 2022
III. About receiver
IP/SMS receiver RL14 is purposed for Central Monitoring Stations (CMS). It is designed to receive
messages transmitted through Trikdis transmission modules, which are sent in TCP/UDP protocols or SMS
messages. After processing received messages, it sends the data to the monitoring software through LAN or
RS232 port.
IV. Receiver functionality
Receiver has an integrated industrial computer with software IPcom v4 operating in OS Linux
environment. Software Ipcom v4 is designed to process message traffic received via 1) receiver network
adapter card, 2) integrated SMS receiver, 3) receiver lead-in RS232.
Network card receives messages sent in TCP/UDP protocols. SMS receiver receives messages sent in
Contact ID codes. RS232 port receives Contact ID codes in Sugard MRL-DG protocol.
Receiver’s functionality is set in the license, which affect the parameters of IPcomControl v4 software.
Receiver’s parameters are set while configuring IPcomControl v4, which must be installed in MS Windows OS
computer, located in the same network as the receiver.
There are multiple channels set for receiving messages and multiple ports for transferring messages to
the monitoring software. The functionality and physical parameters of these channels and ports are
configured while setting up the receiver.
Receiving messages:
Receives messages using TCP/IP or UDP/IP protocols sent by TRIKDIS GPRS communicators G10, G10C,
G10T, G10D via GPRS and/or SMS channels.
Note: A regular size SIM card from chosen GSM network provider must be inserted into integrated SMS
receiver SIM card slot in order to receive messages via SMS channel.
Receives messages using TCP/IP or UDP/IP protocols sent by TRIKDIS Ethernet communicators E10, E10C,
E10T via wired internet networks.
Receives messages using TCP/IP or UDP/IP protocols sent by TRIKDIS GPRS communicators G10F, FireCom
via GPRS and/or SMS channels.
Note: A regular size SIM card from chosen GSM network provider must be inserted into integrated SMS
receiver SIM card slot in order to receive messages via SMS channel.
Receives messages using TCP/IP or UDP/IP protocols sent by TRIKDIS control panels CG3 and SP131 via
GPRS and/or SMS channels.
Note: A regular size SIM card from chosen GSM network provider must be inserted into integrated SMS
receiver SIM card slot in order to receive messages via SMS channel.
Receives messages using UDP/IP protocols sent by TRIKDIS repeaters RR-GSM and R-IP12.
Receives messages sent by receivers from other manufacturers that are connected to lead-in RS232.

User Manual v220127
IP/SMS receiver RL14
www.trikdis.com 5 January, 2022
V. Technical parameters
Parameter Description
Number of IP communicators Unlimited
Number of reception channels Initial license allows two channels
Communication protocols TCP/UPD TRK-3, TRK-6, TRK-7
Physical port of network adapter card RJ-45 (FastEthernet 10/100)
Modem of integrated SMS receiver GSM 850/ 900/ 1800/ 1900 MHz
Integrated SMS receiver SIM card type Standard, not supplied with the receiver
Purpose of RS232 ports It can configured to work as INPUT or OUTPUT for data
transferring
Number of RS232 ports 3
Data output protocols Surgard MLR2-DG, Monas3
Physical type of RS232 ports Male connector DB9
Setting parameters and monitoring the
operation
Computer operating in the same network with MS Windows
32/64 bit Win7, Win8, Win8.1, Win10 and software
IPcomControl v4
Number of workplaces Initial license allows adding 2 workplaces
Primary power supply 100 – 240 V (50 / 60 Hz) AC network.
AC current (Max.): 0.75A/115VAC, 0.5A/230VAC
Power Up to 60W
Backup power supply 12 V, capacity of 18Ah or more. Charging current up to 900 mA.
Operating temperature From 0 °C to +55 °C
Dimensions 19” 1U (450 x 50 x 320 mm)
Weight 2.1 kg
VI. Equipment
IP/SMS receiver RL14 1 pc.
2.5 m length GSM antenna with a magnetic pad 1 pc.
1.5 m length power supply cable 1 pc.
1.8 m length Null Modem-type COM cable (f/f) 1 pc.
5 m LAN cable 1 pc.
CD with software IPcomControl v4 and user manual 1 pc.

User Manual v220127
IP/SMS receiver RL14
www.trikdis.com 6 January, 2022
VII. Receiver elements
A. Front view and light indication.
Front view of the receiver
Light indication
Indicator Description
Power Green light when power supply is on.
Status
Green light when physical and protocol connection between the receiver and message
monitoring software is online.
Red light when physical and protocol connection between the receiver and message
monitoring software is lost.
Yellow light when physical and protocol connection between the receiver and message
monitoring software is online via some described and active ports but has been lost via
the rest.
No light when receiver port is not active or not described.
Event Blue light when a message is being transmitted to the message monitoring software.
B. Rear view and rear panel elements.
Rear view of the receiver
Rear panel elements
Element Description
LAN Connector RJ45 for network adapter card.
COM1 1st serial port RS232 that is set as data lead-in or output (male connector DB9).
COM2 2nd serial port RS232 that is set as data lead-in or output (male connector DB9).
COM3 3rd serial port RS232 that is set as data lead-in or output (male connector DB9).
Reset Microswitch that resets default internet addresses of receiver network adapter card
when pressed and held for more than 5 seconds.
Antenna SMA-type female connector for GSM antenna of integrated SMS receiver.
HDMI HDMI connector for monitor.
USB USB connection.
Connector for receiver grounding circuit.

User Manual v220127
IP/SMS receiver RL14
www.trikdis.com 7 January, 2022
- BAT +
Dismountable connector for backup power supply battery (at least 18 Ah 12 V). Battery
status may be controlled if there are no power supply problems. Battery charging
current - 900 mA.
100-240VAC Power supply cable connector and switch O/I.
VIII. Preparing the receiver for operation
1. Power supply must be turned off when receiver is being prepared for operation, i.e. 1) receiver power
supply cable must be disconnected from the network and 2) receiver connector BAT to which backup
power supply circuit is connected must be unplugged.
Note: Receiver will fully shut down only 2 minutes after turning off the power supply!
2. Insert an already registered regular size SMS card of the chosen network provider into receiver‘s SMS
card slot in order to receive SMS messages from Trikdis message transmission modules.
3. Position the receiver on a solid clean horizontal surface, unscrew fixing screws and remove the top
cover. Insert the SIM card into a SMS receiver‘s SIM card slot. Put side and top covers back on (see
picture below). Screw the top cover.
4. Mount the receiver in a 19” server rack.
5. Screw the GSM antenna.
6. Prepare a LAN according to a principal scheme below:

User Manual v220127
IP/SMS receiver RL14
www.trikdis.com 8 January, 2022
7. Install software IPcomControl v4 (see Configuring the receiver) on the computer that will be used to
configure receiver RL14.
8. Change the IP address of the computer that will be used to configure receiver RL14 to that required by
the receiver manufacturer (see item A under section Configuring the receiver).
9. Connect receiver RL14 and the computer that will be used to configure the parameters of the receiver
using LAN cable
10. Insert the power supply cable connector into the 110-220 V power socket of the receiver and plug the
cable into the mains socket.
11. Turn on the power supply of the receiver, i.e. toggle the power supply switch O/I to I. Power supply is
indicated by the blue light diode Power. A sound signal will indicate that receiver is prepared for
configuration.
12. Configure parameters of receiver RL14 in the following order:
1) Set the parameters of the receiver network adapter card so that receiver may operate in a
designated LAN (see section Connecting to a new receiver);
2) Add and describe ports through which message traffic is directed to the message monitoring
software (see tab Outputs under section Configuring the receiver);
3) Add and describe ports through which message traffic will be receiver (see tabs COM settings and
Receivers under section Configuring the receiver);
4) Add and describe programmable receivers which will direct processed message traffic through ports
to message monitoring software (see tab Receiver under section Configuring the receiver);
5) Add and describe users who will be permitted to log in and perform assigned tasks during operation
of the receiver (see tab Users under section Configuring the receiver).
13. Disconnect the LAN cable from the receiver and the computer (if it does not belong to LAN) once desired
receiver parameters are set.
14. Connect receiver RL14 and the computer with message monitoring software.
Use RS232 cable supplied with the equipment to connect the chosen receiver output COM and
computer with message monitoring software if messages will be transmitted to the message monitoring
software using port RS232;
Connect the receiver and the local area network with operating server-computer with message
monitoring software via receiver network adapter card connector LAN if messages will be transmitted
to the message monitoring software via LAN.

User Manual v220127
IP/SMS receiver RL14
www.trikdis.com 9 January, 2022
IX. Configuring the receiver
Operation parameters of receiver RL14 are set and edited using software IPcomControl v4 on a computer
with OS MS Windows operating in the same LAN. Software may be found in the supplied CD or on
www.trikdis.lt. Install software IPcomControl v4 on the computer.
A. Connecting to a new receiver and setting LAN addresses.
Default addresses of network adapter card:
IP address 192.168.100.3
Port 55000
Subnet mask 255.255.255.0
Gateway 192.168.100.254
In order to restore default settings refer to chapter IX. Resetting default parameters.
1. Computer and receiver must operate in the same network in order to configure the receiver. Change
the network adapter card addresses of the computer that will be used to configure the receiver to
match those indicated in the tab.
2. Use LAN cable to connect the receiver and the computer that will be used to configure the receiver.
3. Turn on the main power supply and wait a few seconds until a sound signal will indicate that receiver
is on.
4. Run IPcomControl v4. Enter the default IP address of the receiver network adapter card and click OK.

User Manual v220127
IP/SMS receiver RL14
www.trikdis.com 10 January, 2022
5. Enter the User name (administrator) and password (admin) when prompted. Click Login.
6. Select IPcomControl v4 tab Configure. Click Get. Enter LAN values into boxes Primary IP, Subnet and
Gateway in order to connect the receiver to the network. Click Set.
7. Receiver should automatically reboot and restart. Software IPcomControl v4 will close automatically.
Receiver is prepared for operation in LAN.
8. Disconnect the LAN configuration cable from the receiver and plug in the cable of local area network
whose addresses were just set in its place.
9. Restore network adapter card addresses of the computer that was used to configure the receiver.
Computer may now operate in previously used networks.
B. Connecting to a receiver operating in LAN.
Receiver operating in LAN is configured using software IPcomControl v4 on a 32/64 bit computer
computer with OS MS Windows Win7/8/8.1/10. Several computers with software IPcomControl v4 may be
connected to the receiver at once. Number of connections is limited by license that may be viewed by clicking
Help in software IPcomControl v4.
1. Run software IPcomControl v4. Enter the IP address of the LAN receiver network adapter card, e.g.,
195.15.184.138, when prompted and click OK.
2
3
1
4
Indice
Altri manuali Trikdis Ricevitore