Unit UTi260K Manuale utente

UTi260K
P/N:110401109316X
Professional Thermal Imager

2
Thank you for purchasing the new UTi260K thermal imager. In order to use this
product safely and correctly, please read this manual thoroughly, especially the
Safety Instructions part.
After reading this manual, it is recommended to keep the manual at an easily
accessible place, preferably close to the device, for future reference.
Uni-Trend guarantees that the product is free from any defect in material and
workmanship within one year from the purchase date. This warranty does not
apply to damage caused by accident, negligence, misuse, modification,
contamination or improper handling. The dealer shall not be entitled to give any
other warranty on behalf of Uni-Trend. If you need warranty service within the
warranty period, please contact your seller directly.
Uni-Trend will not be responsible for any special, indirect, incidental or subsequent
damage or loss caused by using this device.
Preface
Limited Warranty and Liability
UTi260K User Manual

1. Safety Instructions ----------------------------------------------------- 4
2. Structure ------------------------------------------------------------------ 5
3. Display -------------------------------------------------------------------- 6
4. Power On/Off ------------------------------------------------------------ 7
5. Menu Introduction ------------------------------------------------------ 7
6. Operating Instructions ------------------------------------------------ 18
7. Specifications ----------------------------------------------------------- 21
8. Maintenance ------------------------------------------------------------ 23
9. Common Emissivity --------------------------------------------------- 23
To ensure proper use of this product, please read the instructions carefully
before using.
The optimal measuring distance for this product is 1 meter.
To ensure measurement accuracy, please use the product in an operating
environment of 15°C~30°C, <85% RH (non-condensing).
Please use the product indoors without wind.
When changing to a new environment, please turn on the product and leave
it for 10 to 20 minutes before measuring.
The ambient temperature for measuring must be stable. Do not measure in
places with large airflow such as fans and air outlets.
When the measured object comes from a place with a large temperature
difference from the measurement environment, keep it in the measurement
environment for 10 to 30 minutes before measuring.
The product tests the surface temperature of the object. If temperature
compensation is needed, please adjust in the Settings menu.
The product has a self-calibration function. If the reading jumps quickly, please
read the temperature after it gets steady.
After measuring extremely high or low temperature objects, please leave the
product for 10 minutes before next use.
Do not use the product in places with strong sunlight or electromagnetic
interference.
Please do not use the product in flammable, explosive, steamy, wet or corrosive
environments.
Please stop using the product if it is damaged or modified to avoid inaccurate
measurement results.
Please use the correct emissivity to obtain accurate temperature readouts.
To ensure accuracy of the product, please warm it up for 10 to 20 minutes
before measuring if it has not been used for a long time.
When being charged, the internal temperature of the product rises, which will
lead to inaccurate temperature measurement. So, it is not recommended to
take measurements during or right after charging the product.
UTi260K User Manual UTi260K User Manual
Table of Contents
1. Safety Instructions
43

1
2
3
4
5
6
7
8
9
10
1
2
3
4
56
7
8
9
10
2. Structure
Description
USB (Type-C) interface
SD card slot
Interface cover
LED light
Infrared camera lens
Visual light camera lens
Trigger
LCD display
Power button
Description
Flashlight button
Left button
Down button
Up button
Replay button
Right button
Back button
SET button
Tripod mounting hole
Item Item
3.Display
Display size: 2.8”
Display resolution: 320 (vertical) x 240 (horizontal) pixels
Description Description
Item Item
UTi260K User Manual UTi260K User Manual
Center point temperature
Maximum temperature
Maximum temperature point
Minimum temperature point
Main menu
Region of interest (ROI)
11
12
Maximum temperature point in ROI
Temperature bar
Battery status
Date and time
Maximum temperature in ROI
Calibrating…
65
11
12

4.Power On/Off
5.Menu Introduction
5.1 Measurement
5.2 Palette
1. Press the SET button to open the main menu.
2. Press the left/right button to select the option.
3. Press the SET button to enter the Palette menu.
4. Press the up/down button to select the desired palette.
5. Press the SET button to apply the palette.
6. Press the back button to exit.
UTi260K User Manual UTi260K User Manual
Press and hold the power button for 3 seconds to turn on/off the product.
Note: After the product starts the shutdown procedure, it takes 5 to 6 seconds.
Please try to avoid turning on and off the product continuously to avoid damage.
1. Press the SET button to open the main menu.
2. Press the left/right button to select the option.
3. Press the SET button to enter the Measurement menu.
4. Press the up/down button to select Center Spot (center point measurement),
HiLo Spot (maximum and minimum temperature measurement) or ROI.
5. Press the SET button to turn on/off Center Spot, HiLo Spot or ROI.
6. Press the back button to exit.
87

5.3 Point Temperature
1. Press the SET button to open the main menu.
2. Press the left/right button to select the option.
3. Press the SET button to enter the Point Temperature menu.
4. Press the up/down button to select the desired point.
A. Press the SET button to turn on the point and enter the thermal imaging
page.
Press the left/right/up/down button to move the point.
Press the SET button to confirm and read the temperature of the current
point.
B. Press the SET button to turn off the point.
Press the back button to exit.
5.4 Image Mode
UTi260K User Manual UTi260K User Manual
1. Press the SET button to open the main menu.
2. Press the left/right button to select the option.
3. Press the SET button to enter the Image Mode menu.
4. Press the up/down button to select the desired mode from Thermal (infrared
image), Digital (visual light image), Fusion (image blending), and PIP (picture
in picture).
5. Press the SET button to apply the current mode.
6. Press the back button to exit.
Note: If Fusion is selected, users can press the left/right button to select the
desired blending ratio from 0% (pure visual light image), 25%, 50%, 75%, and
100% (pure infrared image) under the thermal imaging page. If Alignment
Distance is selected, users can set the alignment distance (meter) of the fusion
target to 0.5, 1.0 (default), 1.5, 2.0, 2.5 or >3.0.
109

5.5 Settings
To enter Settings menu:
1. Press the SET button to open the main menu.
2. Press the left/right button to select the option.
3. Press the SET button to enter the Settings menu.
5.5.1 Language
To set language:
1. Press the up/down button to select the Language option in the Settings menu.
2. Press the SET button to enter the Language submenu.
3. Press the up/down button to select Chinese or English.
4. Press the SET button to confirm.
5. Press the back button to exit.
5.5.2 Date and Time
To set date and time:
1. Press the up/down button to select the Date and Time option in the settings
menu.
2. Press the SET button to enter the Date and Time submenu.
3. Press the left/right button to select the parameter to be adjusted.
4. Press the SET button to enter the parameter adjustment state.
5. Press the up/down button to increase or decrease the value.
6. Press the SET button to save the settings and return to set other parameters.
7. Press the back button to exit.
5.5.3 Temperature Unit
To set temperature unit:
1. Press the up/down button to select the Temperature Unit option in the Settings
menu.
2. Press the SET button to enter the Temperature Unit submenu.
3. Press the up/down button to select °C or °F.
4. Press the SET button to confirm.
5. Press the back button to exit.
UTi260K User Manual UTi260K User Manual
1211

5.5.4 HI/LO Alert
To set high/low temperature alert:
1. Press the up/down button to select the HI/LO Alert option in the Settings menu.
2. Press the SET button to enter the HI/LO Alert submenu.
3. Press the up/down button to select the desired option.
4. Select HI or LO to adjust the temperature parameter.
5. Select other options to turn the alert on or off.
6. Press the back button to exit.
5.5.5 Measurements
To set measurement parameters:
1. Press the up/down button to select the Measurements option in the Settings
menu.
2. Press the SET button to enter the Measurements submenu.
3. Press the up/down button to select Emissivity or Temperature Comp
(temperature compensation).
4. Press the SET button to enter the parameter adjustment state.
5. Press the up/down button to increase or decrease the value.
6. Press the SET button to save the current setting.
7. Press the back button to exit.
5.5.6 Display Brightness
To set display brightness:
1. Press the up/down button to select the Display Brightness option in the
Settings menu.
2. Press the SET button to enter the Display Brightness submenu.
3. Press the up/down button to select the desired brightness level from Low,
Medium, and High.
4. Press the SET button to confirm.
5. Press the back button to exit.
5.5.7 Auto Power Off
To set auto power off:
1. Press the up/down button to select the Auto Power Off option in the Settings
menu.
2. Press the SET button to enter the Auto Power Off submenu.
3. Press the up/down button to select the desired option from 5 Minutes,
10 Minutes, 30 Minutes, and Off.
4. Press the SET button to confirm.
5. Press the back button to exit.
Note: For emissivity values of common materials, please refer to the Common
Emissivity.
UTi260K User Manual UTi260K User Manual
1413

5.5.8 USB Mode
To set USB mode:
1. Press the up/down button to select the USB Mode option in the Settings menu.
2. Press the SET button to enter the USB Mode submenu.
3. Press the up/down button to select USB Disk or USB Camera.
4. Press the SET button to confirm.
5. Press the back button to exit.
Note: USB disk mode allows users to browse pictures and analyze data on a PC, while USB
camera mode allows users to realize real-time image projection after connecting to a PC.
5.5.9 Auto Save
To set auto save:
1. Press the up/down button to select the Auto Save option in the Settings menu.
2. Press the SET button to enter the Auto Save submenu.
3. Press the up/down button to select Yes or No.
4. Press the SET button to confirm.
5. Press the back button to exit.
Note: Do not remove or insert the SD card in saving pictures. It is recommended to save
no more than 1000 pictures, so as not to affect the response speed of the product. When
the number of pictures exceeds 1,000, please clean up the SD card in time.
5.5.10 System Settings
To enter System Settings submenu:
1. Press the up/down button to select the System Settings option in the Settings menu.
2. Press the SET button to enter the System Settings submenu.
Device Information
To view the device information:
1. Press the up/down button to select the Device Information option in the System Settings
submenu.
2. Press the SET button to view the detail information of the device.
3. Press the back button to exit.
Note: Capacity is the storage capacity of the SD card in use currently.
UTi260K User Manual UTi260K User Manual
1615

Factory Reset
To restore factory settings:
1. Press the up/down button to select the Factory Reset option in the System
Settings submenu.
2. Press the SET button to enter.
3. Press the up/down button to select Yes.
4. Press the SET button to confirm.
5. Press the back button to exit.
Note: During the factory reset process, please do not force other operation to
avoid program errors.
Format SD Card
To format SD card:
1. Press the up/down button to select the Format SD Card option in the System
Settings submenu.
2. Press the SET button to enter.
3. Press the up/down button to select Yes.
4. Press the SET button to confirm.
5. Press the back button to exit.
Note: When formatting the SD card, please do not remove it or perform other
operation to avoid program errors.
6. Operating Instructions
6.1 Image Capture
1. Pull and release the trigger to capture an image.
2. In the manual save mode, press the left/right button to discard or save the
image, and press the SET button to confirm or the back button to return.
3. In the auto save mode, the image will be saved automatically.
Note: Images can only be saved if an SD card is installed.
UTi260K User Manual UTi260K User Manual
1817
Indice
Altri manuali Unit Attrezzature da laboratorio
Manuali Attrezzature da laboratorio popolari di altre marche

Agilent Technologies
Agilent Technologies 5800 ICP-OES Manuale utente

Endress+Hauser
Endress+Hauser Cleanfit CPA875 Manuale utente

NI
NI PXI-5422 Manuale

Collomix
Collomix Aqix Manuale utente

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series Manuale utente

Ocean Insight
Ocean Insight FLAME-NIR+ Manuale utente




















