Vacc-Safe VS350 Manuale utente

USER MANUAL
Model: VS350
www.vaccsafe.com.au
Warning:
Before using this product,
please read this manual
carefully and keep it for
future reference. The design
and specifications are subject
to change without prior
notice for product
improvement.
Vacc-Safe
PHARMACY
REFRIGERATOR

Contents
Product features ................................................................. 2
Safety warnings ................................................................. 1
Precautions and safety measures ...................................... 3
Precautions for use............................................................. 8
Product installation ............................................................. 9
Product compositions and overview ...................................14
Operating instruction...........................................................15
Maintenance and care ........................................................19
Specifications .....................................................................21
Packing list .........................................................................21
Electrical schematic diagram .............................................22

Safety warnings
Warning: Flammable refrigerant is adopted for the product.
WARNING:
WARNING:
WARNING:
WARNING:
Keep all ventilation openings in the enclosure or, in the structure for building-in,
clear of obstruction.
Do not use mechanical devices or other means to accelerate the defrosting process,
other than those recommended by the manufacturer.
Do not damage the refrigerant circuit.
In order to reduce flammability HAZARDS the installation of this equipment shall only
be carried out by a suitably qualified person.
:
DANGER Risk Of Fire Or Explosion. Flammable Refrigerant Used. To Be Repaired Only By
Trained Service Personnel. Do Not Puncture Refrigerant Tubing.
:
CAUTION Risk Of Fire Or Explosion. Flammable Refrigerant Used. Consult Repair Manual
/ Owner’s Guide Before Attempting To Install Or Service This Equipment. All Safety Precautions
Must be Followed.
:
CAUTION Risk Of Fire Or Explosion. Dispose Of Properly In Accordance With Federal Or
Local Regulations. Flammable Refrigerant Used.
This unit is intended for use in commercial, industrial, or institutional occupancies as
defined in the Safety Standard for Refrigeration Systems, ANSI/ASHRAE 15”.
Replacement components and servicing.
The installation and operating instructions shall indicate that component parts shall
be replaced with like components and that servicing shall be done by the
manufacturer’s authorised personnel, so as to minimize the RISK of possible ignition
due to incorrect parts or improper service.
1

Product features
This product can be used to store human biological samples, medicines, vaccines,
biological products, reagents, and materials that need to be stored at 2~8°C.
Product function
Accurate temperature control & traceable data
Microcomputer temperature control display with an accuracy of 0.1°C
Temperature can be set between 2°C to 8°C, and in the box, it fluctuates
≤2°C, adjustable and accurate.
Efficient refrigeration & energy saving mute
World-renowned compressor that focuses on energy saving, environmental
protection, high efficiency and noise suppression.
High efficiency condenser fan and evaporator fan with vortex effect
refrigeration is adopted with stable lasting performance and low noise.
Ensuresthat the temperature in the cabinet is more uniform and stable, and
the cooling speed is more efficient.
Unique technologies of built-in air duct and air curtain are adopted.
Multiple alarms & safe and stable
Sound and light alarms with high and low temperature alarms, power failure
alarm, sensor failure alarm and other functions. Alarm temperature value is
set based on demand.
The design of safety door lock ensures the safety of samples in the box.
User-friendly design
Multi layer encryption shelf design and adjustable height can maximize the
use of space.
The inner LED lights, bright and energy-saving, make the stuff in the box clear
at a glance.
2

Precautions and safety measures
Dear users of Vacc-Safe:
Hi! Thank you for using a Vacc-Safe pharmacy refrigerator.
For your convenience to understand this manual, use the
product, and prevent personal injuries and goods damages,
please read the following instructions thoroughly.
Warning Failure in complying matters
highlighted in warning
signs may cause serious
casualties.
Actions or
operations
that must be
prohibited
Note Failure in complying matters
highlighted in warning
signs may cause serious
casualties, or damages to
the pharmacy refrigerator and
related property losses.
Behavior or
operation
that must be
observed
Product with the symbol
that reads "prevent
fire, stay away from fire
sources".
Warning ------------------------------------------------------------------
P lease use a power socket with a ground wire to prevent
electric shock.
If the power socket is not grounded, the grounding wire
must be installed by professional technicians.
Be sure to place the pharmacy refrigerator firmly on a solid and
flat ground. If the ground is not stable or the place is not
suitable, the pharmacy refrigerator might be overturned or people
will be injured.
3

If the power cord needs to be lengthened, the sectional
area of the lengthened cord shall not be less than 2.5mm . At
the same time, the length is not longer than 3 m. Otherwise,
it may cause a fire or electric shock.
In case of flammable gas leakage, it is necessary to
close the gas leakage valve and open doors/windows,
for ventilation. Do not open any electrical switch, and do
not plug in or pull out the power plug of the pharmacy refrigerator,
otherwise it may cause explosions and fires.
Only professional technicians or after-sales maintenance
personnel can disassemble the pharmacy refrigerator, otherwise
it may cause fires or electric shock.
Please use the special power supply indicated on the
nameplate of the pharmacy refrigerator, otherwise it may cause
fire or electric shock.
If the voltage is lower than 187 V or higher than 242 V,
it is necessary to install more than 4000 W automatic
voltage regulator suitable for motor load.
The power cord of this pharmacy refrigerator is equipped with
a three-wire (grounded) plug, which meets the standard
three-wire (grounded) socket of 10 A.
Under no circumstances should the grounding pin of the
power cord be removed. Make sure that the power plug
and socket are plugged firmly and reliably, otherwise it
may lead to fires.
When unplugging from the power socket, hold the power
plug firmly and remove it. Do not pull the wires of the
power plug directly. If you pull the wire by hand, it may
cause electric shock or fires due to short circuit.
2
4

If the pharmacy refrigerator is not working properly, please
unplug the power plug. It may cause electric shock or fires
if it continues to operate under abnormal conditions.
Before any repair or maintenance of the pharmacy refrigerator,
always disconnect the power supply of the pharmacy
refrigerator to prevent electric shock or personal injuries.
Make sure that the medicine or suspended particles inside
and around the pharmacy refrigerator will not be inhaled during
maintenance, otherwise it may be harmful to health.
When storing toxic, harmful, or radioactive materials,
please use a pharmacy refrigerator in a safe area. Improper use
may cause harm to human health or the environment.
When the pharmacy refrigerator is not used for a long time,
unplug the power plug to prevent electric shock, leakage
or fires caused by the aging power cord.
I f the pharmacy refrigerator is idle for a long time in an
unsupervised area, make sure that children do
not approach
the pharmacy refrigerator and that the disposal
of the
pharmacy refrigerator is to be carried out by the appropriate
personnel. The door should be removed to prevent
accidents such as suffocation.
No flammable, explosive, dangerous or volatile substances
should be stored in pharmacy refrigerator. Do not use
combustible sprays near the pharmacy refrigerator,
otherwise it may cause explosions or fires.
Do not store corrosives such as acids and alkalis in
the
pharmacy refrigerator. The internal components
or electrical
parts of the pharmacy refrigerator may be damaged.
P ackaging plastic bags should not be placed where
children can reach them, because plastic bags may
cause suffocation.
5

Do not climb on the pharmacy refrigerator or put anything
on the pharmacy refrigerator, otherwise it may fall over and
cause personal injuries or damages to the pharmacy refrigerator.
Don't use the pharmacy refrigerator in the open air. When the
pharmacy refrigerator is wet by rain, it may cause electric
leakage or electric shock.
Pharmacy refrigerator should not be placed in damp places or
places vulnerable to splashing water. Otherwise, electric
leakage or electric shock will be caused due to insulation
reduction.
Do not pour water directly on the pharmacy refrigerator,
otherwise it may cause electric shock or short circuit.
Users are not allowed to disassemble, repair or modify
the pharmacy refrigerator by themselves. Otherwise, it may
cause fires or personal injuries due to improper operations.
Do not ground the pharmacy refrigerator through gas pipe,
power supply pipe, telephone line or lightning rod. The above
grounding may cause electric shock or other hazards.
Do not touch any electrical parts such as power plug or
any switch with wet hands, otherwise electric shock may
be caused.
Do not put containers or heavy objects containing water
on the pharmacy refrigerator. If the object falls, it may cause
personal injuries, and the outflow of water will reduce the
insulation and cause leakage or electric shock.
Do not insert metal objects such as nails or wires into
any openings and gaps of the pharmacy refrigerator or into
any vent used for internal air circulation, otherwise electric
shock or injury may be caused by the above objects
contacting with moving parts.
6

Note ---------------------------------------------------------------------
There should be no obstruction around the pharmacy
refrigerator and the ventilation should be smooth. It is
necessary to check the pharmacy refrigerator setting when
restarting the pharmacy refrigerator after power failure or power off.
C hanges in settings may damage stored items.
O nce the power of the pharmacy refrigerator is cut off, it will
take more than five minutes to turn it on again to avoid
damages to the compressor or system.
G loves should be worn during maintenance to avoid
touching the sharp edges or corners and injuries to
personnel.
H old the handle to close the door so that the door will
not catch your fingers.
W hen moving pharmacy refrigerators, the inclination
angle should not be more than 45 degrees.
When transporting the pharmacy refrigerator, be careful not
to trip over pharmacy refrigerator to prevent damages to
pharmacy refrigerator or personal injuries.
P lease do not use the door handle to lift or carry
the device, in case of damages to the pharmacy
refrigerator or personal injuries.
The refrigeration circuit must not be damaged.
D o not use electrical appliances in the storage room
of pharmacy refrigerators except for those recommended
by the manufacturer.
7

Precautions for use
Before putting items into the device, please make sure that the internal
temperature in the cabinet has reached the set temperature, and then put
the items into the pharmacy refrigerator .i n batches. The volume of the
articles in the box should not exceed 1/4 of its volume at a time to prevent
the temperature from rising too much.
The temperature display value of the device is to show the temperature at
the temperature sensor in the storage room. There is a certain difference
between the displayed temperature and the actual temperature at the center
of the device when the device just starts. As the device enters a stable state,
the displayed temperature will gradually reach the actual temperature.
The device box body is provided with a detection hole so as to lead out
the test line in the box during the test. After the test line is led out, it is
necessary to plug the test hole with insulating material again, otherwise
the temperature in the box may not reach the set temperature value, and
condensation will appear around the outside of the through hole.
Please use diluted neutral cleaner to clean the device. Do not use brushes,
acid, gasoline, soap powder, polishing agent or hot water to clean the
device, otherwise the painted surface and plastic rubber parts may be
damaged. Attention: Do not use volatile solvents such as gasoline to clean
plastic and rubber parts.
When the device is not in use for a long time, cut off the power supply and
turn off the battery.
Each time you access the items, please try to reduce the time to open the
door to avoid large fluctuations in temperature and humidity inside the box.
After the door is opened, the temperature inside the box will rise sharply in
a short time. This is normal, and the situation will be restored within 1 hour
after the door is closed.
Under high temperature and high humidity environment, glass door may
condense, which is normal phenomenon and does not affect the storage
temperature in the box.
8