VICI DBS MISTRAL EVOLUTION HYBRID Manuale utente

1
MISTRAL EVOLUTION HYBRID
USER MANUAL www.vicidbs.com
Version 1.03.0000
TECH SUPPORT
Europe, Asia, Africa, Australia & New Zealand:
techsupport@vicidbs.com
USA, Canada, Central & South America:
techsupportus[email protected]
Italy
service@vicidbs.com
VICI AG INTERNATIONAL
Parkstrasse 2
CH-6214 Schenkon
Switzerland
tel: +41 41 925-6200
fax: +41 41 925-6201
web: www.vicidbs.com
APPLICABLE MODELS
This manual is applicable to the following models:
• Mistral Evolution Hybrid
Version 1.03.0000

1
MISTRAL EVOLUTION HYBRID
USER MANUAL www.vicidbs.com
Version 1.03.0000
TABLE OF CONTENTS
1. VERSION HISTORY................................................................................................................................ 2
2. INTRODUCTION.................................................................................................................................... 3
2.1. Symbol Denitions...............................................................................................................................3
3. SAFETY.................................................................................................................................................. 4
3.1. Personal Safety Instructions.................................................................................................................4
3.2. Instrument Safety Instructions ............................................................................................................4
4. SPECIFICATIONS................................................................................................................................... 5
5. PRESENTATION OF DEVICE ................................................................................................................. 6
5.1. Front View............................................................................................................................................6
5.2. Back View............................................................................................................................................6
5.3. Connections........................................................................................................................................7
5.4. Power Supply Settings ........................................................................................................................7
5.5. Transport and Storage ........................................................................................................................7
6. SCHEMES .............................................................................................................................................. 8
6.1. Fluidics.................................................................................................................................................8
6.2. Electrical..............................................................................................................................................9
7. STARTING THE GENERATOR .............................................................................................................. 10
8. SOFTWARE.......................................................................................................................................... 11
8.1. Overview of the Menus.....................................................................................................................11
8.2. Parameters ........................................................................................................................................11
8.3. Diagnostic .........................................................................................................................................12
9. OPTIONAL EXTERNAL TANK.............................................................................................................. 12
9.1. Size of Tank .......................................................................................................................................12
9.1.1. Tank Size Calculation................................................................................................................13
9.2. Where to Get the Tank......................................................................................................................13
10. ALARMS & PRE-ALARMS .................................................................................................................. 14
10.1. Pre-Alarms.......................................................................................................................................14
10.2. Alarms .............................................................................................................................................14
11. TROUBLESHOOTING......................................................................................................................... 15
12. MAINTENANCE................................................................................................................................. 16
12.1. 4000h Maintenance ......................................................................................................................... 16
12.2. 8000h Maintenance......................................................................................................................... 16
13. SPARE PARTS ................................................................................................................................16-17

2
MISTRAL EVOLUTION HYBRID
USER MANUAL www.vicidbs.com
Version 1.03.0000
1. VERSION HISTORY
VERSION DATE COMMENT/CHANGE
1.00.0100 01/10/2017 Layout and initial release, VICI DBS
1.01.0000 12/20/2018 Update
1.02.0000 05/18/2020 New layout, images and graphics, VICI Gig Harbor Group
1.03.0000 07/01/2021 Updated schematics, update to details on 9.3, add chapters 12-13

3
MISTRAL EVOLUTION HYBRID
USER MANUAL www.vicidbs.com
Version 1.03.0000
2. INTRODUCTION
The VICI DBS® Mistral Evolution Hybrid is a self contained generator that produces up to 12 L/min of high
purity nitrogen and 22 L/min of air. The generator is designed to meet the specic requirements of the
Sciex LC/MS. Nitrogen is produced by utilizing a combination of compressor and Carbon Molecular Sieve
(CMS) technology. High and low pressure compressors are carefully matched to the CMS demand to ensure
quite and reliable operation. This unique combination of dual compressor technology has several unique
advantages over all other nitrogen generators commercially available.
2.1 Symbol Denitions
SYMBOL DESCRIPTION
General warning. Caution is necessary when operating the device or control
close to where the symbol is placed, or to indicate that the current situation
needs operator awareness or operator action in order to avoid undesirable
consequences.
The manual must be consulted in all cases where this symbol is marked on
the device.
Risk of asphyxia. Caution is necessary when operating the device in a not
sufciently ventilated area.
Oxidant material. Caution is necessary due to the presence of oxidant material.
WEEE symbol. When discard this product, it must be sent to separate collection
facilities for recovery and recycling.
Fuse. Notify replaceable fuse place.
OR
OR
OR

4
MISTRAL EVOLUTION HYBRID
USER MANUAL www.vicidbs.com
Version 1.03.0000
3. SAFETY
3.1 Personal Safety Instructions
When using your Mistral Evolution Hybrid, basic safety precautions should always be followed, including the
following:
• The quantity of dust in the ambient Air can be very different from one place to another.
We recommend to replace the dust lters every 4000H. In some dusty areas, this
maintenance need to be performed more frequently.
• Clogged dust lter may damage the device or give a bad Nitrogen quality.
• The power supply main cable connector is the disconnect device in case of
emergency, it must be easily accessible at any time.
• If the Mistral Evolution is used in a way not specied by VICI DBS, the protection
provided by the equipment could be compromised.
3.2 Instrument Safety Instructions
• The Mistral Evolution Hybrid is a Nitrogen Generator. Do not let it run with the outlet
open to the air in a low volume room.
• The increase of the Nitrogen (and decrease of oxygen) may cause human disease.
It is the responsibility of the user to check if the room is appropriate or if an O2
measurement is necessary.
• The Mistral Evolution Hybrid rejects Oxygen as waste.
• Oxygen ratio in the air could change around the device in a low volume or not
sufcient ventilated room.
• If fuel gases are present around, their explosive or ammable limits could be
affected. It is the responsibility of the user to check if the room is appropriate or
if an O2 measurement is necessary.

5
MISTRAL EVOLUTION HYBRID
USER MANUAL www.vicidbs.com
Version 1.03.0000
4. SPECIFICATIONS
MISTRAL EVOLUTION HYBRID
Nitrogen ow rate L/min 12 @ 5 barg (80 psig)
Air 1 - ow rate L/min 8 @ 4 barg (60 psig)
Air 2 - ow rate L/min 24 @ 7 barg (100 psig)
Nitrogen purity +98%
Dewpoint oC (oF) -50 (-58)
Outlet pressure barg (psig) 7 (100)
Technology Carbon molecular sieve
Warm up time (minutes) 20
Electrical supply 110-120V 60Hz / 220-240V 50Hz
Power consumption (watts) 1800
Noise level 55 dBA @ 1 meter
Dimensions mm (in) 482W x 641H x 835D (18.9W x 25H x 33D)
Weight kg (lbs) 90 (198)
Shipping dimensions mm (in) 550W x 800H x 940D (21.6W x 31.4H x 37D)
Shipping weight kg (lbs) 115 (254)
Operating temp oC (oF) 15 to 35 (59 to 95)
Outlet connections 3 x 6 mm OD Compression or 1/4”
Certication CE, FCC, MET (UL and CSA compliant)
MODELS & SPECS

6
MISTRAL EVOLUTION HYBRID
USER MANUAL www.vicidbs.com
Version 1.03.0000
5. PRESENTATION OF THE DEVICE
5.1 Front View
Command Buttons (x3)LED Indicator Lights
Backlit Display
5.2 Back View
Relay Alarm
Outlet Compressor
Box Cooling System
Dust Silencer Filter
Outlet Water
Purge
Outlet N2 with Valve
Outlet Pressure
Service Box
Flow Set Pressure
Line Pressure
Power Supply
On/Off Switch
Outlet Source Pressure
Outlet Exhaust
Pressure

7
MISTRAL EVOLUTION HYBRID
USER MANUAL www.vicidbs.com
Version 1.03.0000
5.3 Connections
Power Supply: C-20 Outlet N2 with Valve: G1/4” female
Outlet Water Purge: Ø10mm tube Relay Alarm: 2 pos universal Mate-N-Lock
connector female
5.4 Power Supply Settings
The current power supply setting of the device is indicated on the ID Sticker on the back of the device. The
Mistral Evolution standard setting is 210-230V/50-60Hz.
If other voltages are requested, this should be done when ordering. In this case a transformer will be
installed to transform internally the requested voltage to 110-115 V/50-60Hz. The list of voltage and
frequencies settings possible are bellow. In any case the voltage of the power supplied must stay at
+/- 10% of the nominal value.
VOLTAGE SETTING FREQUENCY FUSE F3 (5X20 OR 6.3 x 32 mm) COUNTRY
110-115 VAC AC50-60 Hz 20 A Japan/U.S.A.
220-240 VAC AC50-60 Hz 10 A Korea/Europe
Please see service manual for the connection of the transformer. General earth connection is done via power
supply main cable.
5.5 Transport and Storage Conditions
Temperature Minimum -10ºC (14ºF), Maximum 45ºC (113ºF)
Humidity Inferior to 90% Rh, non-condensing
Shocks and vibrations during transport Shocks <1g; Vibrations <0.2g/5Hz
Instruments position Horizontal

8
MISTRAL EVOLUTION HYBRID
USER MANUAL www.vicidbs.com
Version 1.03.0000
6.1 Fluidics
6. SCHEMATICS
The above mentioned values are considered for an instrument transported in its original new packing.
The device contains castors to be moved easily. Use the breaks to make the device stable. The Mistral
Evolution Hybrid could be elevated from any points under the chassis base. Recommendations for the
transport
When the instrument is shipped back to the factory for recalibration or repair, the Mistral Evolution Hybrid
should be packed in its original packing with the inlets and outlets protected against any accidental
penetration of dust or particles of the package.
System:
Schematic no:
Date:
Created:
Checked:
Released:
THIS DOCUMENT AND THE INFORMATION WHICH
IT CONTAINS SHALL NOT BE USED, EXPLOITED
OR SOLD, AND SHALL NOT BE REVEALED OR
DISCLOSED TO OTHERS WITHOUT THE EXPRESS
WRITTEN PERMISSION OF VICI. THIS DOCUMENT
SHALL REMAIN THE PROPERTY OF VICI AND
SHALL BE RETURNED UPON DEMAND.
R
Rev.:
Sheet:
By:
Description:
ECN no:
Mistral Evolution Hybrid
air flow diagram 11.06.21 SBU
1
1/1

9
MISTRAL EVOLUTION HYBRID
USER MANUAL www.vicidbs.com
Version 1.03.0000
6.2. Electrical
System:
Schematic no:
Date:
Created:
Checked:
Released:
THIS DOCUMENT AND THE INFORMATION WHICH
IT CONTAINS SHALL NOT BE USED, EXPLOITED
OR SOLD, AND SHALL NOT BE REVEALED OR
DISCLOSED TO OTHERS WITHOUT THE EXPRESS
WRITTEN PERMISSION OF VICI. THIS DOCUMENT
SHALL REMAIN THE PROPERTY OF VICI AND
SHALL BE RETURNED UPON DEMAND.
R
Rev.:
Sheet:
By:
Description:
ECN no:
Mistral Evolution Hybrid
electrical diagram 11.06.21 SBU
1
1/1
Indice
Altri manuali VICI DBS Generatore portatile

VICI DBS
VICI DBS NM PLUS Manuale utente

VICI DBS
VICI DBS GT ULTRA ZERO AIR GENERATOR Manuale utente

VICI DBS
VICI DBS HK PLUS Series Manuale di istruzioni

VICI DBS
VICI DBS MISTRAL Manuale utente

VICI DBS
VICI DBS PCB 1500 Manuale utente

VICI DBS
VICI DBS HK PLUS Series Manuale utente

VICI DBS
VICI DBS MINI WHISPER Manuale utente

VICI DBS
VICI DBS MISTRAL EVOLUTION 10 Manuale utente

VICI DBS
VICI DBS PG Plus Rack 100 Manuale utente

VICI DBS
VICI DBS NM Plus 100 FID Tower Manuale utente