Vision Tech Shop TVC Series Manuale utente

- 1
-
TVC
Counting Scale
V1.09b-V1.11
REV:Y8, Nov 2019

TVC Counting Scale Technical Manual (v1.09b-v1.11)
- 2
-
CONTENTS
1. PRECAUTIONS ....................................................................................................... - 3 -
2. SPECIFICATIONS ................................................................................................... - 4 -
3. INSTALLATION ........................................................................................................ - 5 -
4. DESCRIPTION ......................................................................................................... - 8 -
5. OPERATION........................................................................................................... - 10 -
1. Power ON/OFF............................................................................................... - 10 -
2. Zero .................................................................................................................. - 10 -
3. Tare .................................................................................................................. - 10 -
4. Weighing Units ............................................................................................... - 10 -
5. PARTS COUNTING ...................................................................................... - 10 -
5.1. Setting Unit Weight ............................................................................ - 10 -
5.2. Entering a Known Unit Weight. ........................................................ - 11 -
5.3. Parts Counting. ................................................................................... - 11 -
5.4. Automatic Part Weight Updates ....................................................... - 12 -
5.5. Check Weighing and Setting High / Low limits. ............................. - 12 -
5.5.1. Checking Alarm ....................................................................... - 12 -
5.5.2. Check Counting / Weighing Limits ....................................... - 12 -
6. Accumulation ................................................................................................ - 14 -
6.1 Prepare for accumulation. .................................................................. - 14 -
6.2 Accumulate operation ......................................................................... - 14 -
6.3 Recall Memory ..................................................................................... - 14 -
6.4 Memory Clear ....................................................................................... - 14 -
7. Back light ......................................................................................................... - 15 -
6. PARAMETERS....................................................................................................... - 16 -
6.1 PARAMETERSETTING .............................................................................. - 16 -
6.2 PARAMETER MENU BLOCK ................................................................... - 16 -
7. CALIBRATION ....................................................................................................... - 18 -
7.1 Linear Calibration ........................................................................................ - 18 -
7.2 Normal Calibration ....................................................................................... - 20 -
8. RS-232 PROTOCOL ............................................................................................. - 22 -
9. ERROR CODES .................................................................................................... - 24 -
10. DRAWING............................................................................................................. - 26 -

TVC Counting Scale Technical Manual (v1.09b-v1.11)
- 3
-
1. PRECAUTIONS
Read this manual before operating or servicing this
equipment.
Follow these instructions carefully.
Disconnect this equipment from the power source before
cleaning of performing maintenance.
Keep the manual for your future reference.
Avoid extremes of temperature. Do not place in direct
sunlight or near air conditioning vents.
Avoid unsuitable tables. The tables or floor must be rigid
and not vibrate. Do not place near vibrating machinery.
Avoid unstable power sources. Do not use near large
users of electricity such as welding equipment or large
motors.
Avoid high humidity that might cause condensation.
Avoid direct contact with water. Do not spray or immerse
the scales in water.
Avoid air movement such as from fans or opening doors.
Do not place near open windows.
Do not stack material on the scales when they are not in
use.
Keep the scales clean.

TVC Counting Scale Technical Manual (v1.09b-v1.11)
- 4
-
2. SPECIFICATIONS
DIMENSION(inch/mm)
SPECIFICATIONS
MODEL TVC -6 TVC -12 TVC -30 TVC -60
Capacity 3kg/6lb 6kg/12lb 15kg/30lb 30kg/60lb
Readability 0.1g/0.0002lb
0.2g/0.0005lb
0.5g/0.001lb 1g/0.002lb
Resolution 30000
Weighing Units kg /lb
Housing ABC Plastic and Stainless Steel platform
Interface RS232 Output as standard
Operation
Temperature
-10°C - 40°C / 14°F - 104°F
Power Ac adaptor 12V/500mA , Battery 6V/3.2AH
Display 3x6 digits 15 mm LCD display with white LED back light
Dimensions
(WxDxH)
10.5 (W) x 12 (D) x 4 (H) / 265 (W) x 313 (D) x 108.8 (H)
Weight 4.1kg(9lb)

TVC Counting Scale Technical Manual (v1.09b-v1.11)
- 5
-
3. INSTALLATION
Unpacking
Carefully take the balance out of its package, make sure it’s not damaged and all
accessories are included.
Accessories:
1. Balance
2. Adaptor
3. Stainless steel pan
4. Product manual
Keep the packaging material for your future use.
Parts Description
Pan
Display
Key board
Water mark bubble
On / Off Switch
Adaptor Jack
Adjusting feet

TVC Counting Scale Technical Manual (v1.09b-v1.11)
- 6
-
Installation
Place the scale on a table.
Carefully place the pan to the four holes on the top cover.
Adjust the water mark bubble level.
Connect the adaptor pin to the adaptor jack.
Adaptor jack is located below the right side of the scale.
Adaptor connects into your AC power socket.
Pluggable equipment must be installed near an easily accessible socket
outlet with a protective ground/earth contact.
Turn on the power switch.
On / Off switch is located below the right side of the scale. Press switch
forward to turn on the scale. If you want to turn off, press the switch
backward.
Display will show the scale capacity and will start self-checking.
After self-checking, display will return to normal weighing mode.
Then you can start your operation.
Note: Initial Start Up.
Warm-up time of 15 minutes stabilizes the measured values after switching on.
Level Adjusting
Place the scale on a table.
Check the water mark. If bubble is not centered, adjust the leveling feet until it
becomes centered. Check the level when you change the location.

TVC Counting Scale Technical Manual (v1.09b-v1.11)
- 7
-
Connect Adaptor and Charging
To charge the battery, insert the adaptor pin to jack. Adaptor simply plugs
into the main power. The scale does not need to be turned on.
The battery should be charged for 12 hours for full capacity.
Left to the count display is an LED to indicate the status of battery charging.
When the scale is plugged into the mains power, the internal battery will
be recharged. If the LED is green, the battery is fully charged. If it is red,
the battery is running low on battery and if yellow, the battery is being
charged.
Do not use any other type of power adaptor than the one supplied with the
scale.
Verify that the AC power socket outlet is properly protected.
Note: Please charge the battery before using the scale for the first time.

TVC Counting Scale Technical Manual (v1.09b-v1.11)
- 8
-
4. DESCRIPTION
Keyboard
Keys
Press this key to
to
Enter individual unit weights and the present tare
Clear incorrect entries and error conditions
Returns the display to zero.
Storing the current weight as tare value. Subtracting
the tare value from the total weight and displays the
result as net weight. and clear the tare weight.
Add the current count data aggregated. Also evokes
the memory if pressed to balance empty. Can add up
to 99 values, or until it reaches the maximum
displayable digits.
Recall the accumulator memory.

TVC Counting Scale Technical Manual (v1.09b-v1.11)
- 9
-
Manually enter the weight of sample, also changes the
unit if they are enabled.
Enter the numbers of items, used for the unit weight.
Press and hold the key to select weighing units
To set the limits of the number of items counted and
weight.
Used to print the results to printer
Display
Weight Display
BATT.
Low Battery
Net
Net Weight Display
Stable
Stable Display
Zero
Zeroing Display
Unit Weight Display
Insufficient number of samples
Insufficient number of counts
Preset
To show preset count when stored
Count Display
Memory
To show when value stored
Charge
Status of the battery charging

TVC Counting Scale Technical Manual (v1.09b-v1.11)
- 10
-
5. OPERATION
Initial Start-Up
Warm-up time of 15 minutes stabilizes the measured values after switching on
1. Power ON/OFF
Power switch is located below the right side of the scale. Press the key
forward until to turn on. The display is switched on and the self test is
started. If you want to switch off press the key forward again.
2. Zero
Environmental conditions can lead to the balance exactly zero in spite
of the pan not taking any strain. However, you can set the display of
your balance to zero any time by pressing key and therefore
ensure that the weighing starts at zero.
3. Tare
The weight of any container can be tared by pressing tare button so that
with subsequent weighing the net weight of the object being weighed is
always displayed.
Load weight on the pan.
Press key. Zero is displayed, and tare is subtracted.
Remove weight from the platform. Tared weight is displayed. It can set
only one tare value. It can display with a minus value.
Press key. Zero is displayed, tare weight is cleared.
4. Weighing Units
In the zero point and stable indicator on, press key to select the
weighing units(kg/lb)
5. PARTS COUNTING
5.1. Setting Unit Weight
For this function you need to know the average weight of the objects to
count. This value can be obtained by weighing a known number of pieces
so that the balance calculation.
Scales can be used to calculate the unit weight or the manual input of unit
weight can be used. It can increase the precision of the unit weight at any
time during the process of counting by the count displayed and pressing
Altri manuali per TVC Series
1
Questo manuale è adatto per i seguenti modelli
4
Indice
Altri manuali Vision Tech Shop Scala

Vision Tech Shop
Vision Tech Shop VK-2D Manuale utente

Vision Tech Shop
Vision Tech Shop TVP Series Manuale utente

Vision Tech Shop
Vision Tech Shop TVC Series Manuale utente

Vision Tech Shop
Vision Tech Shop DSW-100 Manuale utente

Vision Tech Shop
Vision Tech Shop DLP-300 Manuale

Vision Tech Shop
Vision Tech Shop TVD Series Manuale utente

Vision Tech Shop
Vision Tech Shop VK-10S Manuale utente

Vision Tech Shop
Vision Tech Shop VK-4C Manuale utente

Vision Tech Shop
Vision Tech Shop TVD Series Manuale utente

Vision Tech Shop
Vision Tech Shop TPD Series Manuale utente