Weller FT12 Manuale utente

FT12
Operating nstructions
FT12_2019:WFE_H5.qxd 04.12.19 11:41 Seite 1

SGBI
NL
F
D
1. Aansluitnippel voor FE-soldeerbout
2. Hoofdfilterpatroon
3. Vacuümkamer
4. Afvoerluchtfilter
5. Persluchtaansluiting
6. Smoorklep
7. Klemveer
1. Raccord pour fer à souder FE
2. Cartouche filtrante principale
3. Carter à vide
4. Filtre d'évacuation d'air
5. Raccord d'air comprimé
6. Vanne d'étranglement
7. Ressort de retenue
1. Anschlussnippel für FE-Lötkolben
2. Hauptfilterkartusche
3. Vakuumgehäuse
4. Abluftfilter
5. Druckluftanschluß
6. Drosselventil
7. Halterfeder
1. Nippolo di collegamento per stilo
brasatore FE
2. Cartuccia filtro principale
3. nvolucro sotto vuoto
4. Filtro dell'aria di scarico
5. Collegamento aria compresa
6. Valvola a farfalla
7. Molla di ritegno
1. Anslutningsnippel för FE-lödkolv
2. Huvudfilterpatron
3. Vakuumhus
4. Frånluftfilter
5. Tryckluftanslutning
6. Spjällventil
7. Hållarfjäder
1. Connector nipple for FE soldering bit
2. Main filter cartridge
3. Vacuum casing
4. Exhaust filter
5. Compressed air connection
6. Control valve
7. Retaining spring
5
4
3
2
1
1
7
6
FT12_2019:WFE_H5.qxd 04.12.19 11:41 Seite 2

The 3-stage filter installed, comprising fine particulate air fil-
ter F7 and wide band gas filter (50% activated carbon; 50%
Puratex) is ideally suited in this configuration to the extrac-
tion of soldering fumes. The particulate filter and the gas fil-
ter are contained in the main filter cartridge. Both filter ele-
ments are disposable filters and the fine particulate air filter
(preliminary filter) can be changed several times before the
main filter cartridge has to be replaced.
Thank you for placing your trust in our company by purcha-
sing the Weller FT12 soldering fume extraction unit.
Production was based on stringent quality requirements
which guarantee the perfect operation of the device.
1. Caution!
Please read these Operating nstructions and the attached
safety information carefully prior to initial operation. Failure
to observe the safety regulations results in a risk to life and
limb.
The manufacturer shall not be liable for damage resulting
from misuse of the machine or unauthorised alterations.
The Weller FT12 soldering fume extraction unit corresponds
to the EC Declaration of Conformity in accordance with the
basic safety requirements of Directives 2004/108/EC,
2006/95/EC and 2011/65/EU (RoHS).
2. Description
The Weller FT12 soldering fume extraction unit is equipped
with a maintenance-free compressed air converter for vacu-
um generation and is therefore ideally suited to continuous
industrial operation. The compressed air converter is ade-
quately designed to extract the soldering fumes from 2
Weller Fumex-Extraction soldering bits. The vacuum hoses of
the FE soldering bits are connected directly to the FT12 sol-
dering fume extraction unit. To operate the FT12 cleaned, dry
compressed air (3.5 bar - 7 bar) is required. t is possible to
shut off the compressed air using the shut-off valve on the
unit's compressed air connection. The compressed air con-
nection is combined with a control valve, which allows the
compressed air to be regulated.
Note!
The FT12 soldering fume extraction unit is not suitable for the
extraction of flammable gas.
Warning:
nly remove the compressed air hose from the unit in its
unpressurised state.
To remove the compressed air hose, press the unlocking ring
of the rapid-fitting pipe union and pull out the hose.
Together with the exhaust air filter (activated carbon), which
absorbs odours caused by compressed air, the FT12 is used
as a circulating air unit. t is not necessary to draw off the
exhaust air. Both filter elements are disposable filters, where
the fine dust filter (prefilter) can be changed multiple times.
The main filter cartridge must be replaced after 12 months at
the latest.
Warning:
When using extraction equipment, the legal limits with
regard to contaminants in the workplace must be obser-
ved and regularly checked by the operator of the extrac-
tion equipment.
Technical data
Operating pressure in bar /psi: 3.5 - 7 bar / 50-100 psi
of clean dry
compressed air
Compressed air connection: OD 6 mm hose
Height: 200 mm / 7.9 inches
Diameter: 120 mm / 4.78 inches
Weight (approx.) in kg/lb: 1.5 / 3.3
Noise level (at 1m interval) dB: 37
Air consumption l/min (SCFH): 13 (27)
Main filter: F7 fine dust filter
Particulate filter
Wide band gas filter
99.95%
50% Activated charcoal,
50% Puratex
3. Commissioning
Place the FE soldering bit in the safety rest. The FT12
soldering fume extraction unit is equipped for the connection
of 2 Weller FE soldering bits (1). On connection of an FE
soldering bit, the vacuum hose is attached to the open
connector nipple. The second connector remains closed.
Only take off the closure cap on connection of a second
vacuum hose.
nsert the compressed air hose, external diameter 6 mm
(PUN-6 x 1) into the compressed air connection (5) of the
FT12 as far as it will go.
f the compressed air supply is correct (3.5 - 7 bar, clean
oil-free) connect the FT12 to the compressed air supply
system and, if necessary, open the control valve (6).
Maintenance
Before maintenance work is undertaken, the unit must be
switched to its unpressurised state.
English
FT12_2019:WFE_H5.qxd 04.12.19 11:41 Seite 9

n order to guarantee trouble-free operation of the unit, the
vacuum tube and extraction hose of the FE soldering bit
must be cleaned regularly. f heavily soiled, the extraction
tube can be placed in a gas-tight sealed container in clea-
ning alcohol (spirit) until the flux residues have dissolved.
Warning:
When using cleaning agents, the legal safety provisions
with regard to their handling must be observed. The cle-
aning agent must be treated as hazardous waste and
must be disposed of in accordance with the prevailing
local regulations.
f the extraction performance of a cleaned FE soldering bit is
no longer adequate, the filters must be checked.
The preliminary filter can be changed several
times before the main filter has to be replaced.
When original WELLER filters are used in the prescribed
manner, the service lives of the particulate filter and the wide
band gas filter are designed to be approximately equal.
To change the filter, the 3 retaining springs (7) must be pus-
hed outwards. The main filter cartridge and the
preliminary filter below it can then be replaced without
the use of tools. The exhaust filter (4) can also be changed.
The exhaust air filter cartridge can then be taken out of the
vacuum casing.
Warning:
When inserting filters, take care to follow the correct
sequence and fit them in the appropriate position. The
soiled filters must be treated as hazardous waste.
4. List of accessories (Europe only)
T005 29 166 99 FE 75 soldering bit 80 W
T005 25 125 99 FE retrofit kit for LR-21
T005 13 125 99 FE retrofit kit for DSX 80
T005 15 020 99 KH-20 rest for soldering bit FE 75
Replacement filters:
210-0323-ESD Exhaust filter
T005 36 410 99 Compact filter
T005 36 421 99 Fine dust filter F7 (3 pcs.)
5. Scope of supply
The FT12 is equipped with:
1 Fine particulate air filter F7
1 Main filter cartridge consisting of particulate filter and gas
filter 50% activated carbon, 50% Puratex
1 Exhaust air filter
1 PUN 6 x 1 compressed air hose
1 Set of operating instructions
1 Safety information
Subject to technical alterations and amendments!
See the updated operating instructions at
www.weller-tools.com.
English
FT12_2019:WFE_H5.qxd 04.12.19 11:41 Seite 10

T005 56 112 10 / 12.2019
T005 56 112 10 / 09.2014
Weller-Logo_2011in „Weller-Blau“
Größen-Variationen
www.weller-tools.com
Weller®is a registered Trademark and registered Design of Apex Tool Group, LLC
© 2019, Apex Tool Group, LLC
G E R M A N Y
Weller Tools GmbH
Carl-Benz-Str. 2
74354 Besigheim
Phone: +49 (0) 7143 580-0
Fax: +49 (0) 7143 580-108
C H I N A
Apex Tool Group
2nd Floor, Area C, 177 Bi Bo Road,
Pudong New Area
Shanghai 201203
Phone: +86 (21) 60 88 02 88
Fax: +86 (21) 60 88 02 89
U S A
Apex Tool Group, LLC
14600 York Rd., Suite A
Sparks, MD 21152
Phone: +1 (800) 688-8949
Fax.: +1 (800) 234-0472
FT12_2019:WFE_H5.qxd 04.12.19 11:42 Seite 49
Altri manuali per FT12
2
Indice
Altri manuali Weller Scrubber

Weller
Weller MG100S Manuale utente

Weller
Weller Zero-Smog WFE 20D Manuale utente

Weller
Weller WFE P Manuale utente

Weller
Weller MG100S Manuale utente

Weller
Weller Zero Smog 4V Manuale utente

Weller
Weller MG100S Manuale utente

Weller
Weller Zero Smog TL Manuale utente

Weller
Weller WFE 2ES Manuale utente

Weller
Weller Zero Smog TL Manuale utente

Weller
Weller Zero Smog EL Manuale utente