WESTERSTRAND AUREA III Manuale utente

WESTERSTRAND Document: DOK11071en05
Author:
T
An
Date: 2022-04-20
Page: 1 of 16
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Instructions
AUREA III

WESTERSTRAND Document: DOK11071en05
Author:
T
An
Date: 2022-04-20
Page: 2 of 16
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
General
Digital clock is for indoor application with second has 6 digits and colon displaying time.
Digital clock is for indoor application without second has 4 digits and colon displaying time.
The digits for the second consist of 7 segments.
The Digital clock can be programmed for alternating time/temperature/date display in 0-25 sec
intervals.
Temperature sensor is not included. It is an option.
The programming of time, Synchronisation and light intensity are made by push buttons, located at
one side of the cover.
The digital clock can operate stand alone with a built in quartz crystal as time reference, as a slave
clock to a master clock transmitting 24 V polarised 1/1 minute impulses or synchronised by TC, DCF.
If the DLS-function is set, the clock is changing, summer and winter time, the last Sunday in March
and the last Sunday in October automatically.
The clock has adjustable light intensity.
If power failure occurs the display is turned off. The internal clock continues to keep the correct time
for 48 hours. After power failure the display is turned on and correct time is shown.
If not specified in order the clocks are preset from factory in impulse Synchronisation mode.

WESTERSTRAND Document: DOK11071en05
Author:
T
An
Date: 2022-04-20
Page: 3 of 16
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Installation wall mounted
Unscrew 4 screws, 2 pieces at each side.
Remove the back plate from the casing and mount it on the wall using 4 screws suitable for the
wall material.
AUREA III with second
AUREA III without second

WESTERSTRAND Document: DOK11071en05
Author:
T
An
Date: 2022-04-20
Page: 4 of 16
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
If operated by synchronisation, check the strapping according to the drawing pages 7 and page 8.
Connect the cables according the schema page 5 or 6.
Connect the power 230VAC, 50Hz. according the schema page 5 or 6. When the clock is
permanently installed a readily accessible disconnect device shall be incorporated in the fixed
wires (2-polar, 3mm contact gap).
Connect the flat ribbon cable and assemble the front.
Set the digital clock. See Programming.

WESTERSTRAND Document: DOK11071en05
Author:
T
An
Date: 2022-04-20
Page: 5 of 16
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Connection
The connections are made on the inside of the back plate (see below.)
AUREA III with second
Connection Synchronisation wire
TC/MIN-imp 3,4
DCF 2-line 3 – V+, 5 – GND
DCF 3-line 3 – V+,4- DCF, 5 – GND

WESTERSTRAND Document: DOK11071en05
Author:
T
An
Date: 2022-04-20
Page: 6 of 16
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
AUREA III without second
Connection Synchronisation wire
TC/MIN-imp 3,4
DCF 2-line 3 – V+, 5 – GND
DCF 3-line 3 – V+,4- DCF, 5 – GND

WESTERSTRAND Document: DOK11071en05
Author:
T
An
Date: 2022-04-20
Page: 7 of 16
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Strapping/DIP switch setting for TC / MIN-impulse (default)
Strapping/DIP switch setting for DCF-radio (2 –wire) computer board

WESTERSTRAND Document: DOK11071en05
Author:
T
An
Date: 2022-04-20
Page: 8 of 16
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Strapping/DIP switch setting for DCF-radio (3 –wire) computer board
The DIP-switch on the computer board should be set as follows:
Dip 1: OFF Display format is HH:MM.
ON Display format is HH:MM:SS.
Dip 2: OFF always OFF
Dip 3: OFF TC/Min impulse-synchronisation. (default)
ON DCF synchronisation.
Dip 4: OFF TC/Min impulse or 3-wire DCF synchronisation. (default)
ON 2-wire DCF synchronisation.
Dip 5: OFF DCF synchronisation.
ON TC/Min impulse synchronisation.(default)
Dip 6: OFF ½ Min impulse synchronisation.
ON TC/Min impulse synchronisation or DCF synchronisation. (default)
Dip 7: OFF always OFF
Dip 8: OFF always OFF

WESTERSTRAND Document: DOK11071en05
Author:
T
An
Date: 2022-04-20
Page: 9 of 16
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Synchronisation
Stand-alone
If the clock does not have an external synchronisation, it operates Stand-alone.
Minute impulse
Make the strapping according to the drawing for strapping page 7.
Connect the minute impulse wire according to the schema page 5 or 6.
The clock can be set in synchronisation or slave mode.
Synchronisation mode:
Set the clock for synchronisation, mode InSy See programming page 11.
Set time and wait for next minute impulse. The clock will be synchronised
Slave mode:
Set the clock for slave, mode InSL See programming page 11.
Set time and wait for next minute impulse. The clock operates as a slave clock.
TC
Check the strapping according to the drawing for strapping page 7.
Connect the TC wire according to the schema page 5 or 6.
Set the clock for synchronisation, function DCF See programming page 11.
When a correct time message appears the clock sets the time.
The clock will blink colon when it is in sync and accepts transmitted code.
DCF
Check the strapping according to the drawing for strapping page 8.
Connect the DCF wire according to the schema page 5 or 6.
Set the clock for synchronisation, function DCF See programming page 11.
When a correct time message appears, the clock sets the time.
The clock will blink colon when it is in sync and accepts transmitted code.

WESTERSTRAND Document: DOK11071en05
Author:
T
An
Date: 2022-04-20
Page: 10 of 16
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Connection temperature sensor (this is an option).
AUREA III with second
AUREA III without second
Temperature sensor connection
1. Brown
2. Black
5. Screen
Indice
Altri manuali WESTERSTRAND Orologio marcatempo