WTI IPS-800 Manuale utente

WTI Part No.: 13506
Rev. B
IPS-800/1600 Series
Internet Power Switches
Models:
IPS-800
IPS-800-CE
IPS-1600
IPS-1600-CE
Firmware Version: 1.41 and Higher
User’s Guide
Model IPS-1600
Model IPS-800


i
Warnings and Cautions:
INSTALLATION INSTRUCTIONS
SECURE RACKING
If Secure Racked units are installed in a closed or multi-unit rack assembly, they may require
further evaluation by Certification Agencies. The following items must be considered.
1. The ambient within the rack may be greater than room ambient. Installation should be such
that the amount of air flow required for safe operation is not compromised. The maximum
temperature for the equipment in this environment is 45°C. Consideration should be given to
the maximum rated ambient.
2. Installation should be such that a hazardous stability condition is not achieved due to
uneven loading.
INPUT SUPPLY
Check nameplate ratings to assure there is no overloading of supply circuits that could have an
effect on overcurrent protection and supply wiring.
GROUNDING
Reliable earthing of this equipment must be maintained. Particular attention should be given
to supply connections when connecting to power strips, rather than direct connections to the
branch circuit.
No Serviceable Parts Inside; Authorized Service Personnel Only
Do not attempt to repair or service this device yourself. Internal components must be serviced by
authorized personnel only.
• Shock Hazard - Do Not Enter
Disconnect Power
If any of the following events are noted, immediately disconnect the unit from the outlet and
contact qualified service personnel:
1. If the power cord becomes frayed or damaged.
2. If liquid has been spilled into the device or if the device has been exposed to rain or water.
Two Power Supply Cables
Note that this unit includes two separate power circuits, with a power supply cable for each
circuit. Before attempting to service or remove this unit, please make certain that both power
cables are disconnected.

ii
IPS-800/IPS-1600 Series - User’s Guide
FCC Part 15 Regulation
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy, and if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Plug the equipment into an outlet on a circuit that is different from the one used by the
receiver.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC rules. Operation of this device is subject to the
following conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate the
equipment
EMC, Safety, and R&TTE Directive Compliance
The CE mark is affixed to this product to confirm compliance with the following European
Community Directives:
• Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of Member
States relating to electromagnetic compatibility;
and
• Council Directive 73/23/EEC of 19 February 1973 on the harmonization of the laws of
Member States relating to electrical equipment designed for use within certain voltage
limits;
and
• Council Directive 1999/5/EC of 9 March on radio equipment and telecommunications
terminal equipment and the mutual recognition of their conformity.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations.
Cet appareil numérique de la classe AB respecte toutes les exigences du Reglement Canadien sur
le matériel brouilleur.
This product meets the applicable Industry Canada technical specifications

i
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
2. Unit Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
3. Quick Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1. Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1.1. Apply Power to the IPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1.2. Connect your PC to the IPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.2. Communicating with the IPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
4. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.1. Power Supply Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.1.1. Installing the Cable Keepers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.2. Connection to Switched Outlets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4.3. Serial COM / RS232 Port Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4.3.1. Connecting a Local PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4.3.2. Connecting an External Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4.4. Connecting the Network Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
5. Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.1. System Mode and User Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.2. Communicating with the IPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
5.2.1. Accessing the Web Browser Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
5.2.2. Accessing the Text Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
5.3. Configuration Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
5.3.1. The General Parameters Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
5.3.2. The Serial Parameters Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
5.3.3. Plug Parameters Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
5.3.3.1. Plug Passwords and Co-Location Features . . . . . . . . . . . . . . . 5-12
5.3.3.2. The Boot / Sequence Delay Period. . . . . . . . . . . . . . . . . . . . . . 5-13
5.3.4. Network Parameters Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15
5.3.4.1. IP Security Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16
5.3.5. The Telnet Parameters Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18
5.3.6. Web Server Parameters Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19
5.4. Save Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20
6. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
6.1. Operation via the Web Browser Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
6.1.1. The Plug Status Screen - Web Browser Interface . . . . . . . . . . . . . . . . . . 6-1
6.2. Operation via the Text Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
6.2.1. The Plug Status Screen - Text Interface . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
6.2.2. Switching and Reboot Commands - Text Interface . . . . . . . . . . . . . . . . . 6-4
6.2.3. Applying Commands to Several Plugs - Text Interface . . . . . . . . . . . . . . 6-6
6.3. Logging Out of Command Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
6.4. The Automated Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
6.5. Manual Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
7. Saving and Restoring Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
7.1. Sending Parameters to a File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
7.2. Restoring Saved Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
8. Upgrading the IPS Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1

ii
IPS-800/IPS-1600 Series - User’s Guide
Appendices
A. Interface Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-1
A.1. Serial COM / RS232 Port Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-1
B. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-2
C. Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-3
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Index-1
List of Figures
2.1. IPS-800 Back Panel (120 VAC Model Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.2. IPS-1600 Back Panel (120 VAC Model Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
3.1. Plug Status Screen - Web Browser Interface (IPS-800 Shown) . . . . . . . . . . . . . . . . . . . 3-3
3.2. Plug Status Screen - Text Interface (IPS-800 Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
5.1. Plug Status Screen - Web Browser Interface (IPS-800 Shown) . . . . . . . . . . . . . . . . . . . 5-2
5.2. Plug Status Screen - Text Interface (IPS-800 Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
5.3. General Parameters Menu - Web Browser Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
5.4. General Parameters Menu - Text Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
5.5. Serial Parameters Menu - Web Browser Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
5.6. Serial Parameters Menu - Text Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
5.7. Plug Parameters Menu - Web Browser Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
5.8. Plug Parameters Menu - Text Interface (Plug 1 Shown) . . . . . . . . . . . . . . . . . . . . . . . . 5-11
5.9. Network Parameters Menu - Web Browser Interface . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
5.10. Network Parameters Menu - Text Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
5.11. IP Security Menu - Text Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16
5.12. Telnet Parameters Menu - Web Browser Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18
5.13. Telnet Parameters Menu - Text Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18
5.14. Web Server Parameters Menu - Web Browser Interface . . . . . . . . . . . . . . . . . . . . . . . . 5-19
5.15. Web Server Parameters Menu - Text Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19
6.1. Plug Status Menu - Web Browser Interface (IPS-800 Shown) . . . . . . . . . . . . . . . . . . . . 6-2
6.2. Plug Status Screen - Text Interface (IPS-800 Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
6.3. The IPS Help Screen - Text Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
A.1. COM Port Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-1

1-1
1. Introduction
Electronic equipment sometimes "locks-up," requiring a service call just to
flip the power switch to perform a simple reboot. The IPS-800/1600 Series
Internet Power Switches give you the ability to perform this function from
anywhere, just point your browser to the IPS’s IP address, enter the secure
password, and you’re just a click away from remote power On, Off or Reboot!
Intelligent Power Control
In addition to web browser access, the IPS can also communicate over any
TCP/IP network using standard Telnet, or out-of-band using an external
modem and basic VT100 type terminal emulation.
Security Features and Co-Location Features
To ensure security, web browser access requires the user to enter an assigned
user name and password. The IPS provides two levels of operational
passwords; the System Administrator Level, which allows access to all
configuration and switching functions, and the User Level, which only allows
access to assigned plugs and cannot be used to change unit configuration.
In addition to password security features, the IPS also includes an address
specific IP security mask, which can be employed to prevent unauthorized
network access to the IPS command mode.
Easy to Configure, Easy to Use
The IPS can be configured over the network, via modem, or locally via the IPS
COM port. Easy to use commands let you assign a location name, set system
parameters and view plug status. Outlets can be switched On, Off, or booted
using plug numbers or names.
Reliability and Support
The IPS is built in the USA and backed by a two year warranty. NetReach
products are installed in thousands of network sites world wide. Our
customers know they can depend on WTI for superior quality and reliability
for their most mission-critical operations.

1-2
IPS-800/IPS-1600 Series - User’s Guide
IPS-800, IPS-1600, IPS-800-CE and IPS-1600-CE Units
This User’s Guide discusses the IPS-800, IPS-1600, IPS-800-CE and
IPS-1600-CE Internet Power Switches. Throughout this User’s Guide, all four
units are referred to as "IPS". The IPS-800 includes eight switched 100 to
120 VAC power outlets. The IPS-1600 includes sixteen switched 100 to 120
VAC power outlets. The IPS-800-CE includes eight switched 208 to 240 VAC
power outlets. The IPS-1600-CE includes sixteen switched 208 to 240 VAC
power outlets. All other features function identically, except where noted.
Typographic Conventions
Throughout this manual, typefaces and characters have been used to denote the
following:
COURIER FONT Indicates characters typed on the keyboard.
For example, /ON 3 or /OFF 4.
[Bold Font] Text set in bold face and enclosed in square brackets
indicates a specific key. For example, [Enter] or [Esc].

2-1
2. Unit Description
As shown in Figure 2.1 and Figure 2.2, the IPS back panel includes connectors,
LEDs and manual controls described below:
Figure 2.1: IPS-800 Back Panel (120 VAC Model Shown)
➀ Bus "A" Power Inlet and Circuit Breaker: An IEC-320-C14 AC inlet
and circuit breaker which supply power to the Circuit "A" outlets. Also
includes cable keeper (not shown.)
• Model RPS-820: 208 - 240 VAC Power Inlet, 10 Amp Circuit Breaker.
• Model RPS-830: 100 - 120 VAC Power Inlet, 15 Amp Circuit Breaker.
➁ Bus "B" Power Inlet and Circuit Breaker: An IEC-320-C14 AC inlet
and circuit breaker which supply power to the Circuit "B" outlets. Also
includes cable keeper (not shown.) Includes the same components listed
in Item 1 above.
Figure 2.2: IPS-1600 Back Panel (120 VAC Model Shown)

2-2
IPS-800/IPS-1600 Series - User’s Guide
➂ Bus "A" Switched Plugs and Plug Indicators: AC Outlets that can be
switched On, Off or rebooted in response to user commands.
• IPS-800: Four 100-120 VAC, NEMA 5-15 Outlets with indicator
lights. 15 Amps Total Load.
• IPS-1600: Eight 100-120 VAC, NEMA 5-15 Outlets with indicator
lights. 15 Amps Total Load.
• IPS-800-CE: Four 208-240 VAC, IEC-320-C13 Outlets with indicator
lights. 10 Amps Total Load.
• IPC-1600-CE: Eight 208-240 VAC, IEC-320-C13 Outlets with
indicator lights. 10 Amps Total Load.
➃ Bus "B" Switched Plugs and Plug Indicators: AC Outlets that can be
switched On, Off or rebooted in response to user commands. Includes
same components listed in item 3 above.
➄ Default Button: This button can be used to either reset the unit to default
parameters or manually toggle all plugs On or Off:
• Default Parameters: With the Main Power switch set in the Off
position, press and hold the Default Button, then set the Main Power
switch in the On position and release the Default Button. All menu
defined parameters will be reset to default values.
• Manual Plug Toggle: Press the Default Button and hold it down for
three seconds. All IPS power outlets will be toggled On or Off.
Note: If desired, the Default Button’s manual plug control
capabilities can also be disabled as described in Section 5.3.1.
➅ Unit Status Indicators: Two LED Indicators which function as follows:
• ON: Lights when power is applied to the IPS Unit.
• RDY: Flashes continuously when the IPS is ready to recieve
commands.
➆ Network Port and Activity Indicator: An RJ45 Ethernet Port
for connection to your TCP/IP network. The default IP Address is
192.168.168.168, for more information, please refer to Section 5.3.4. The
Activity Indicator flashes to indicate activity at the Network Port.
➇ Main Power Switch: Applies power to the IPS Unit. This switch must
be "On" in order for the IPS to function. Note that this switch is not used
to set the On/Off status of the switched outlets.
➈ COM / RS232 Port: A DB9, RS232 serial port (DTE), for connection to
a local terminal or external modem, as described in Section 4.3.
Questo manuale è adatto per i seguenti modelli
3
Indice
Altri manuali WTI Interruttore

WTI
WTI CAS-81 Manuale utente

WTI
WTI AFS-16-1 Istruzioni per l'installazione

WTI
WTI AFS-16-1 Manuale utente

WTI
WTI NBB-1600 Manuale utente

WTI
WTI APS-8M Manuale utente

WTI
WTI RPC Series Istruzioni per l'installazione

WTI
WTI CMS-16 Manuale utente

WTI
WTI RAB-14A Manuale utente

WTI
WTI PLS-345 Manuale utente

WTI
WTI RPC-4850 Series Manuale utente

WTI
WTI APS-8M Manuale utente

WTI
WTI APS-16 Manuale utente

WTI
WTI NPS-4HS15 Series Istruzioni per l'installazione

WTI
WTI IPS-15 Manuale utente

WTI
WTI IPS-15 Manuale utente

WTI
WTI RPC-40L8A4 Series Manuale utente

WTI
WTI SS-8B Manuale utente

WTI
WTI Net Reach RPC-4840N Manuale utente

WTI
WTI IPS-400 Manuale utente

WTI
WTI NPS-2HD Manuale utente





















