LIABILITY DISCLAIMER
This device is for use exclusively on a radio controlled (RC) model. RC models
are not toys. Moving parts can present a hazard to operators, bystanders and
anyone or anything that could be reached by the RC model. Improper opera-
tion, maintenance or assembly can potentially cause an RC Model to pose a
danger to persons or objects including but not limited to the possibility of caus-
ing serious physical injury and even death. After leaving its facilities the man-
ufacturer has no way of maintaining control or supervision over the assem-
bly and/or operation of the RC model or the addition of this device to the RC
Model therefore the manufacturer and/or its agents assume no responsibility or
liability whatsoever for any damages including but not limited to ones generat-
ed by incidental or consequential damages. The operator of the RC Model as-
sumes all responsibility and liability that could result from the correct or incor-
rect operation of the RC Model and/or malfunction of any part or device used.
This product is intended to be used by experienced adult radio control model
operators under controlled safety conditions and on locations properly autho-
rized and setup for safe ying and away from other people. This product must
not be operated without reasonable personal or commercial Liability Insurance.
Under no circumstance should a minor be allowed to operate any radio con-
trolled model without the approval, supervision and direction of his/her parent
or legal guardian who takes full responsibility and assumes full liability of every
kind for the minor’s actions.
Do not operate an RC models within the vicinity of homes, trees, electrical
lines during inclement weather or rain or near crowds of people.
www.XGuardRC.com

Page: 3 Copyright 2020 XGuard RC. All rights reserved
XGuard IntelliSwitch
CONTENTS
PORTS DIAGRAM ..................................................................................... 4
CORRECT BATTERY CONNECTOR POLARITY................................... 5
CONNECTION FOR HIGHER CURRENTS............................................ 6
MOUNTING THE SWITCH ...................................................................... 7
LOCATOR ALARM SWITCHED ON BY RADIO SWITCH................... 8
SWITCH OPERATION ............................................................................... 9
PROGRAMMING THE UNIT...................................................................10
ENTERING PROGRAMMING MODE ................................................... 11
QUICK PROGRAMMING SEQUENCE GUIDE .................................... 11
MUSICAL TONES MEANING .................................................................12
DIMENSIONS ............................................................................................13
INSTALLATION HOLE PATTERN............................................................13

Page: 4 Copyright 2020 XGuard RC. All rights reserved
XGuard IntelliSwitch
PORTS DIAGRAM
Page: 4
Input Port:
Red is Positive (MAX 9 Volts DC)
Black is Negative (GND)
Do not use higher voltage than 2S
LiPo batteries. Overvoltage
or Reverse voltage damage
is not covered by warranty
← Output 1 & Locator Switch (TOP)
← Output 2 (BOTTOM)
ON/OFF
Pushbutton
High-Current Output Port
Buzzer/Alarm

Page: 5 Copyright 2020 XGuard RC. All rights reserved
XGuard IntelliSwitch
A) Polarity for an EC-3 Connector
Positive side of EC3
connector (Flat Side)
Positive wire (Red)
EC3 Connector
(Not Included)
B) Polarity for an XT60 Connector
Positive side of EC3
connector (Flat Side)
Positive wire (Red)
XT60 Connector
(Not Included)
CORRECT BATTERY CONNECTOR POLARITY
Solder the wires
and add heat
shrink tubbing
Solder the wires to the con-
nectors and slide them into
the housing
Warning: Overvoltage
or Reverse voltage
damage is not covered
by warranty
Warning: Overvoltage
or Reverse voltage
damage is not covered
by warranty

Page: 6 Copyright 2020 XGuard RC. All rights reserved
XGuard IntelliSwitch
CONNECTION FOR HIGHER CURRENTS
Connect AWG 14 wires to
the screw terminal block as
shown.
*WARNING*
Do not use solder on the
cable ends that connect
into the terminal block.
Tighten the screws
rmly to secure the
wires to the terminal
block.

Page: 7 Copyright 2020 XGuard RC. All rights reserved
XGuard IntelliSwitch
MOUNTING THE SWITCH
A) Double-Sided Tape
B) Panel Mount
Use two pads of dou-
ble-sided tape 1mm
or thicker on the buzz-
er side to attach to a
clean surface of your
aircraft
Make sure that your panel
mounting hole dimensions
are at least the size of the
ones in this diagram.
Mount the switch using the
supplied screws and carbon
ber cover plate.
WARNING: Do not over-
tighten the screws or you
will break the plastic thread.
Add two pieces
of thin double-
sided tape
13mm x 6.25mm
(not included)

Page: 8 Copyright 2020 XGuard RC. All rights reserved
XGuard IntelliSwitch
Program an unused channel like AUX1 to be controlled by a
switch. Use this channel to turn on or of the locator buzzer by
plugging it to the top port as shown below.
LOCATOR ALARM SWITCHED ON BY RADIO SWITCH
Turn locator buzzer
on by using the
radio switch
If you want to control the
locator buzzer plug a switched
channel into the switch’s top port
Connect the servo wires to
two receiver/FBL ports
ON
OFF
Three
Position
Switch
ON
OFF
Two
Position
Switch
Note: If the positions are reversed go to the radio’s
setting screen and reverse the switch channel.

Page: 9 Copyright 2020 XGuard RC. All rights reserved
XGuard IntelliSwitch
A) WHEN BATTERY IS FIRST CONNECTED TO THE SWITCH
Wait until the switch is armed and ready
which is indicated by alternating blinking
GREEN and RED LEDs.
Once it’s armed you can click once and
the switch will turn on and send power to the output ports. The se-
lected battery mode of operation is indicated by a series of beeps
from 1 to 6 depending on what is programmed as the mode of op-
eration. If not clicked ON withing 3 seconds it will go to standby.
B) WHEN SWITCH IS ON STANDBY
If you turned the switch o via holding the the ON/OFF button for
more than three seconds the switch turned OFF by entering into
standby mode. When in standby mode you need to click once to
arm the switch which is indicated by alternating blinking GREEN
and RED LEDs.
Once it’s armed you can click once and the switch will turn on and
send power to the output ports. The selected battery mode of op-
eration is indicated by a series of beeps from 1 to 6 depending on
what is programmed as the mode of operation. If not clicked ON
withing 3 seconds it will go to standby.
SWITCH OPERATION

Page: 10 Copyright 2020 XGuard RC. All rights reserved
XGuard IntelliSwitch
The switch comes pre-programmed from factory for 2S LiPo
with audible warnings and switch active.
If you want to change the settings you can program the switch
for other battery types and to ignore the channel that activates
the locator if so wanted.
The switch has the following programmable settings:
A) Type of battery and warning or no warning:
• 1 beep) 2S LiPo Battery with Audible and LED Voltage Warnings
• 2 beeps) 2S LiPo Battery with only LED Voltage Warnings
• 3 beeps) 5cell NiMh Battery with Audible and LED Voltage Warnings
• 4 beeps) 5cell NiMh Battery with only LED Voltage Warnings
• 5 beeps) 2S LiFe Battery with Audible and LED Voltage Warnings
• 6 beeps) 2S LiFe Battery with only LED Voltage Warnings
B) Ignore the switch signal
• 7 beeps) Ignore Locator Alarm Switch Signal
Lipo Warning voltage: 6.7V (3.35V per cell)
Lipo Emergency voltage: 6.1V (3.05V per cell)
NiMh Warning voltage: 5.2V (1.04V per cell)
NiMh Emergency voltage: 4.8V (0.96V per cell)
LiFe Emergency voltage: 6.2V (3.1V per cell)