Xvive U4 Manuale utente

IN-EAR MONITOR
WIRELESS SYSTEM
Manual

02
This Class B digital apparatus complies with Canadian
ICES-003.
IC Caution: RSS-Gen Issue 4 December 2014"&"CNR-Gen
4e Décembre 2014:
This device complies with Industry Canada licence-
exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2)
This device must accept any interference, including
interference
that may cause undesired operation
of the device.
CERTIFICATION
Radio Approvals:
FCC Part 15.249, FCC Part 15 B, RSS-210 (Canada), EN 300
440 (Europe), EN 301.489 (Europe), Japan Radio 2.4 GHz
Band (Japan), MIC ARIB STD-T66 (Japan), California 65, CE.

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE
RECEIVED, INCLUDING INTERFERENCE THAT MAY
CAUSEUNDESIRED OPERATION.
Warning: Changes or modications not expressly approved
in writing by Xvive may void the users authority to operate
this equipment.
RF Exposure Statement: This transmitter must not be
co-located or operated in conjunction with any other
antennae or transmitter.
Note: This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment o
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment
and the receiver.
• Connect the equipment into an outlet on a circuit
dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV
technician for help.
This Class B digital apparatus complies with Canadian
ICES-003.
03
CERTIFICATION

04
Hereby, SHENZHEN FZONE TECHNOLOGY CO., LTD,
declares that this type of equipment is in compliance
with the essential requirements and other relevant
provisions of Directive 2014/53/EU
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
SAFETY INSTRUCTIONS FOR
LITHIUM-ION
RECHARGEABLE BATTERIES
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT REMOVE SCREWS.
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THE APPLIANCE TO RAIN OR MOISTURE.
If abused or misused, the rechargeable batteries may
leak. In extreme cases, they may even present a risk of
explosion, re, heat, smoke or gas. Xvive does not accept
any liability for damagearising from abuse or misuse.
• Keep away from children.
• Only charge rechargeable batteries with chargers
recommended by Xvive.
• Observe correct polarity.
• Pack/store charged rechargeable batteries so that the
terminals cannot contact each other
(danger of shorting out/re hazard).
• Do not expose to moisture.
• Switch rechargeable battery-powered products o
after use.
• Only charge rechargeable batteries at ambient
temperatures between 10°C/50°F and 40°C/104°F.
• When not using rechargeable batteries for extended
periods of time, charge them regularly
(about every three months).
• Do not mutilate or dismantle.

05
INFORMATION ABOUT COLLECTION
AND DISPOSAL OF OLD ITEMS
AND USED BATTERIES
Cd
These symbols on the products, packaging, or on any
documents in the package mean it is incorrect to mix the
used electrical and electronic products and batteries with
general household garbage.
• Do not heat above 60°C/140°F, e.g. do not expose to
sunlight or throw into a re.
• Immediately remove rechargeable batteries from obviously
defective products.
• Do not continue to use defective rechargeable batteries.
• Only use rechargeable batteries specied by Xvive.
• Dispose of rechargeable batteries at special collection
points or return them to your specialist dealer.
• Store the products in a cool and dry place at room
temperature (approx. 20°C/68°F).
• Remove the rechargeable batteries if the products will
not be used for extended periods of time.
To protect our environment, please take old products
and used batteries to proper collection places, and
follow your national legislation and the Directives
2012/19/EU and 2006/66/EC.
To deal with these old products and batteries
properly,
please help to save valuable resources
and prevent any
possibility of side eects on human health and our
environment due to the inappropriate disposal of the old
products and used batteries.
You can contact your local authority for getting more
helpful information on how to dispose the recycling and
collection of the old products and batteries.
[For business users in the European Union]
If you want to discard electrical and electronic item, please
contact your dealer or supplier for further information.
[Information on Disposal in other Countries outside
the European Union]
These symbols are only valid in the European Union.
Please contact your local authorities or dealer for more
information on disposal of old items and used batteries.

1. Carefully observe all instructions in the U4 manual.
2. Do not to perform service operations beyond those
described in the U4 Manual. Service is required when
the device was damaged in any way, such as:
• liquid was spilled or objects were dropped into
the device,
• the unit was exposed to rain or moisture,
• the unit does not operate normally or signicant
changes in performance occur,
• the unit is dropped or the housing is damaged.
WARNING: BEFORE USING YOUR XVIVE 2.4 GHz WIRELESS INEAR MONITOR SYSTEM,
CAREFULLY READ THE OPERATING INSTRUCTIONS.
IMPORTANT SAFETY INSTRUCTIONS
PLEASE READ THESE INSTRUCTIONS AND KEEP THEM IN A SAFE PLACE
3. Do not place near heat sources, such as radiators,
heating ducts, or appliances which produce heat.
4. Guard the device against objects or liquids entering
the device. Do not use or store the unit close to water.
5. Clean only with a damp cloth.
6. Only use attachments/accessories specied by
the manufacturer.
7. Prolonged listening at high volume levels may cause
irreparable hearing loss and/or damage. Always be
sure to practice “safe listening.”
07
06

LISTENING TO AUDIO AT EXCESSIVE VOLUMES CAN
CAUSE PERMANENT HEARING DAMAGE. USE AS LOW
A VOLUME AS POSSIBLE.
Overexposure to excessive sound levels can damage
your ears, resulting in permanent noise-induced hearing
loss. Do not use earphones for a long time and set the
volume below 70%.
The U4 personal wireless monitoring system provides
high-delity sound reproduction for performers onstage,
in the studio and in rehearsal. This is a portable wireless
system with nothing to set up. Just plug-and-play to
immediately enjoy your monitoring system!
FEATURES:
• 2.4 Ghz wireless in-ear monitoring system
•Solid RF connection over a range of up to 27 m / 90 feet
(actual range depends on RF signal absorption,
reection and interference)
• Up to 107 dB signal-to-Noise ratio 110 dB for clear and
detailed audio at any volume
• High resolution audio at 24 bit / 48 kHz
• Wide frequency response range 20 Hz – 20 kHz
• Dynamic range 107 dB
• Less than 5 ms latency, simultaneous transmission
on 6 channels
• 5 hours of battery life
(rechargeable battery for both Transmitter & Receiver)
•Smooth frequency response with any kind of headphones
• Balanced mono XLR or unbalanced mono TS input
U4 SET PRODUCT INTRODUCTION
PACKAGE DETAILS
WARNING
1x
1x
1x
1x
1x
1x
U4 Transmitter
U4 Receiver
USB Cable
XLR Male to 1/4" TS Male Adapter
Manual
Bag
07

2
3
4 5
1
7
8
9
6
10
1 Input: balanced XLR input jack
2 Spring: circumferential spring provides ground
connection to metal housing parts
3 Lock: secures transmitter
4 Aux/Line mode: select AUX or line level mode
5 Power switch: switches unit on/o
6 Channel status LED: indicates selected channel
7 Channel switch: selects channels 1-6
8 USB charging port
9 Power status LED, indicates power status:
LED o = 100% ~ 30%
Solid red = 29% ~ 11%
Blinking red = less than 10%
10 Antenna
BASIC OPERATION
U4 TRANSMITTER
08

21
5
4
6
7
8
1 Power switch: switches unit on/o
2 Headphone Output: 3.5mm output
Connect to earphones or headphones
3 Channel status LED: indicates selected channel
4 Channel switch: selects Channels 1-6
5 Volume control: adjust the volume of headphone output
6 RF Status LED:
ON = Transmitter is on and link is established
Flashing = Signal connection interference
OFF = Transmitter o or unlinked
7 Power status LED, indicates power status:
Led o = 100% ~ 30%
Solid red = 29% ~ 11%
Blinking red = less than 10%
8 USB charging port
9 Antenna
BASIC OPERATION
U4 RECEIVER
9
3
09

QUICK START
POWER ON
Turn the power switch to the ‘on’ position:
the channel indicator will light up.
POWER ON
POWER ON
ON
OFF
BATTERIES AND CHARGING
Connect to
the socket
The U4 includes a USB charging cable, which you can connect
to a USB charger adapter or other USB charging device.
Note: Turn o the power switch while charging. Please do
not use the U4 while charging—this may reduce battery life.
Always store the U4 at
room temperature
When storing the unit,
please check the
battery state regularly
and charge if necessary.
15 minutes
30 minutes
1 hour
2.5 hour
30 minutes
1 hour
2 hours
5 hours
CHARGING TIMES BATTERY LIFE
Connect
Power
OR
10
QUICK START
Altri manuali per U4
2
Indice
Altri manuali Xvive Sistema microfonico