Quick Installation Guide
Videoportero - VDP03-B3 Kit
VDP03-B3 Kit A

Residential Video Door Phone
Instructions for Installation and Operation
Please read the instructions carefully before use to
ensure correct and proper operation.
Fast guide
Machine Translated by Google

2. Indoor Unit
1. Safety Precautions
1.Product Introduction
Microphone
It is applicable to places such as homes, residences, apartments, offices and hospitals.
Adjust music volume and select
ringtone
Speak
LCD a Color
The intercom and doorbell have a loud and clear volume level. According to the manual, the effective transmission distance is up to
100m (Manual Page 9 - Wiring Requirements); If a multi-door controller is used, a maximum of four units can be connected to realize
multi-entry access.
Opening
1. Presentation of the Pro
VDP03-B3 Kit 1 1
The product is a wired color video door entry system. The system is made up of two parts, the outdoor unit and the indoor unit. The two
units are connected with quad core cables. The indoor unit uses 15V DC to perform doorbell call, monitoring, intercom and remote
opening functions. TFT-LCD screen is used to provide clear images, bright colors and no distortion. A high-definition CMPS camera is
used to provide good night vision effects.
Silence
Monitor
Figure 1
Machine Translated by Google

In the standby mode of the indoor unit, firstly press the ” button to turn on the display, and
then press the “ button to activate the
ringtone and enter the “change ringtone” setting. The system is equipped with 25 tones of different lengths. The “ button is pressed
once to change a tone. After selecting the proper tone, release the button. The last volume
will be the ringtone when the system is used by anyone.
1.Mute setting
3. Ringtone volume adjustment
Connection with an outdoor unit
2 Manual
In indoor unit standby mode, firstly press “ button to turn on the display, and then
press “ button to turn on ringtone and enter “ringtone
volume” setting.
In the standby mode of the indoor unit, first press the “ button to turn on the screen,
and then press the “ button to turn off the doorbell
and intercom, without affecting the image display. If you need to turn on the doorbell and intercom, press the “ ” button again in the
mode
Volume adjustment
”
”
DC 15V Power Interface
“
It has three levels, large, medium and small. Press the “ ” button for two seconds each time to gradually increase or
decrease the volume.
”
” of the monitor.
Connection with the next indoor unit
”
”
”
Figure 2
Disturbance free mode will be activated after activating the mute function
two . Change the ringtone
2. Indoor unit functions
”
After turning off the device, all ringtone settings will be reset to factory settings.
A Set the ring tone of the indoor unit
Machine Translated by Google

to talk to the visitor.
A. Installation and location of the indoor unit
5. If it is necessary to resume the conversation after hanging up, first press the “
B. Make a mark and drill a hole on the wall
will deactivate if the button is pressed again. The screen automatically turns off in 30 seconds if the call is not answered.
one time.
and then the button
Vertical Effective Reach
VDP03-B3 Kit 3
2. The user inside can press the button “ to talk to the visitor.
to open the door.
”
”
”
First, determine the location and
height to install the indoor unit; the
reference height is 150-165 cm from the
center of the screen to the ground.
Drilling diameter: about 1.5cm
B.Instructions for doorbell operation
”
6. In indoor unit standby mode, press “ button first and then “ button to unlock the door, the display will
turn off automatically in 90 seconds or it
can be turned off by pressing “ button.
Approximately 175 cm
Make a mark and drill a hole after
determining the location on the wall.
3. In intercom mode, indoor user can press “ talk” button 4. In intercom mode, indoor user can press “talk”
button, or the conversation will end automatically in 90 seconds.
”
3.Instructions for installing the indoor unit
Note: The conversations will be activated when you press the “ button
for the first time and will be
”
”
”
Approximately 150 cm
Figure 3
Figure 4
1. When any visitor presses the call button on the outdoor unit, the screen of the indoor unit will show the outdoor image in
real time and the doorbell will ring.
”
“
to finish of
Effective range: 30cm
electric felling
150cm-165cm
30cm
Machine Translated by Google

Source of
Screw
power supply 15Vw
C. Fix the base of the indoor unit
Indoor Unit
5-wire cable
As shown in the figure: Pull out the
base; open the package to take out
the rubber plugs and screws.
D. Fix the indoor unit
Figure 5
Drilling diameter: about 1.5cm
1.Take the indoor unit and power supply;
Figure 6
4 Manual
2.Insert the power plug and 5-wire
connector
1.Drill a hole, drilling diameter 6mm;
2.Fix the rubber stopper on the
3.Place the indoor unit horizontally on
the base.
Fixed base support
in the hole made;
3.Fix the base with screws.
Machine Translated by Google

Monitoring time
1. Product Presentation
Input: AC100-240
vision infrared
VDP03-B3 Kit 5
Color HD TFT LCD
25
Terminal Wiring
Indoor unit connector (4
Pins)
Speaker
Speaker (2 Pines)
resolution 480
Standby: ÿ1W
5PX2.54
90 seconds
infrared night vision
Indoor unit connector (4
Pins)
4. Indoor unit parameters
Salida: DC15V 1200mA
Talk Time
Microphone
nocturnal
800
Operating Temperature
Microphone
Connector for the
electric lock
Figure 7
Power supply
Operating: ÿ10W
-20 °C - 60 °C
90 seconds
call button
Connector for the electric lock
(2 Pins)
call button
Screen
*
Number of ringtones
Power
Camera
Camera
3. Outdoor Unit
Machine Translated by Google

First, determine the location
and height to install the
outdoor unit; the reference
height is 150 to 165 cm from
the center of the outdoor unit
to the ground.
Equipped with a rain cover, protection level 4, for outdoor use.
6 Manual
2.Outdoor unit functions
Vertical Effective Reach
D.Door opening
A. Call and intercom
3.Outdoor unit installation
It can be directly connected with a 12V electric lock. If any other type of lock is used, you must use a 12V
access control power supply (with control +, control -).
When a visitor presses the call button on the outdoor unit, they can communicate with the indoor unit.
A.Installation and location of the outdoor unit
Avoid installing the outdoor
unit in any place with strong
direct sunlight.
Figure 8
Approximately 175 cm
They can talk on the intercom after the indoor unit answers.
Horizontal effective reach
b.Night vision
Effective range: 30cm
Approximately 150 cm
Infrared or white light is used to clearly see any visitor a meter away at night.
Effective range: Approx 50cm
Figure 9
C. Rainproof
30cm
Machine Translated by Google

Screw
Pull out the rain cover; open
the screw pack to take out the
rubber bushings and screws
Figure 11
B. Make a mark and drill a hole on the wall
D. Fix the outdoor unit
Screw
Make a mark and drill a hole
after determining the location on
the wall.
a diameter of
approximately 6mm
1.Drill a hole, with
electric felling
2.Fix the rubber plug into the
hole above
rain cover outdoor unit
3.Fix the cover with screws.
Drilling diameter: about 1.5cm
1.Take out the outdoor
unit; 2.Connect the 4-pin connector
and the 2-pin connector;
3.Place the outdoor unit in front of
the rain cover and fix the bottom
with the hexagon screw.
Hexagonal screw
Figure 10
4-wire cable
For outdoor installation, a
waterproofing treatment of the
wall must be carried out.
C. Fix the rain cover of the outdoor unit
Figure 12
VDP03-B3 Kit 7
As the picture shows:
Machine Translated by Google

Night vision Infrared or white light night vision
Figure 13
Green--- Intercom between displays (multiple displays can be used)
Interior
2PX2.54lock wiring
Based on the distances, the wiring requirements and the diameter of the cables are different. The following table shows the cable
requirements for the different distances:
Yellow --- Video Blue --- Audio
RVV4*0.50
8 Manual
4-wire cable
rain cover
1.Wiring requirements
Feeding
with rain cover
Standby: ÿ1W Operating: ÿ2W
51-100m
E. Completing the installation
4. Indoor unit parameters
lock voltage DC12V
1-30m
Exterior
Operating temperature -20 °C - 60 °C
Black---Ground Red--- VCC
RVV4*1.0
15V supply
Terminal Wiring
Indoor unit power supply
4PX2.54
A.Intercom Wiring Requirements
Wiring colors and functions:
RVV4*0.30
Power supply
Camera HD-CMOS camera
4-wire cable
31-50m
4. Wiring
Machine Translated by Google
Indice
Altri manuali ZKTeco Sistema di interfono

ZKTeco
ZKTeco MULTIUNITIES VE02-03-04-06-08-10-12-A01 Manuale utente

ZKTeco
ZKTeco D0BPA Manuale utente

ZKTeco
ZKTeco SpeedFace-V3L Manuale utente

ZKTeco
ZKTeco Aura12 Manuale utente

ZKTeco
ZKTeco SpeedFace-V3L Manuale utente

ZKTeco
ZKTeco VT07-B22L Manuale utente

ZKTeco
ZKTeco PA22 Manuale utente

ZKTeco
ZKTeco FaceDepot-7BL Manuale utente

ZKTeco
ZKTeco SpeedFace-V3L Manuale utente

ZKTeco
ZKTeco FaceDepot 4A Manuale utente