Precautions for Handling 12701A
To operate the 12701A correctly and safety, please observe the following instructions. Note that ADC Cor-
poration bears absolutely no responsibility for the result of operations caused due to incorrect or inappro-
priate use of this instrument.
Please observe the following instructions to prevent danger such as electric shock:
(1) Always use the safety mechanism of the 12701A that allows and stops voltage application by opening
and closing the cover. (Connect the LID SIGNAL of the 12701A and the INTERLOCK or LID SIG-
NAL of the measuring instrument using a cable.
(2) Ground the 12701Abefore use.
(3) Do not touch the test box while voltage is being applied.
When the HI OUTPUT of the 6245, 6246 (Bch), 6242 or 6244 and the FORCE/SENSE 1 to 8 on the
rear panel of the 12701A are connected, and the relay terminal DG 1 to 8 and the TEST BOX GUARD
are connected, the test box and DG will become the same potential, and the maximum voltage of the
HI OUTPUT may occur on the test box.
(4) When placing or removing DUT, check chat no voltage applied to the 12701A.
(5) Close the cover during measurement to perform accurate measurement.
The cover has a shielded, light-shielded and safety structure.
(6) Watch out for vibration to perform accurate measurement.
The vibration of a cable or fixture during low current (1 pA or lower) measurement may cause varia-
tion in measured values.
(7) Check that the voltage or current applied to the 12701A is within the maximum input voltage or cur-
rent range.
Note that the operating temperature range varies depending on the maximum input current.
(8) Use the test box A04509with the average current value for a second of 1 A or less. The maximum in-
put current value for DC is 1 A. For pulse, the average current value for a second that is obtained by
the following formula should be 1A or less.
Average current = Input current value (up to 20 A peak) × Pulse width / Pulse cycle
e.g. When the input current value is 20 A and the pulse cycle is 1 s, the pulse width should be 50 ms
or less. When the input current value is 20 A and the pulse cycle is 10 ms, the pulse width should
be 0.5 ms or less.
(9) When connecting a measuring instrument with the 12701A
zFor how to handle the measuring instrument, refer to its operation manuals.
zGround the measuring instrument before use.
zWhen using the R8340 or 8340A as measuring instrument, short-circuit the LO and the GND.


Preface*
12701ATest Fixture Operation Manual
Preface
This manual describes the functions of the 12701A test fixture, how to set up and how to measure.
zManual Configuration
This manual consists of the following chapters:
1. Introduction
(1) Product Overview
(2) Supplied Accessories and Optional Accessories
(3) Environmental Conditions
(4) Cleaning, Storage and Transportation of the
Product
Be sure to read through this chapter
before use.
2. Panel Description
(1) Relay Terminals
(2) Rear Panel
Describes the name and function of
each part on the panel.
3. Measurement Examples
(1) Resistance Measurement
(2) Current Measurement
Describes how to use the 12701A.
4. Functional Description
(1) Driving Guard Function
(2) Internal Connection
Describes the driving guard function
and the internal connection.
5. Specifications Describes the specifications.
Appendix 1. Test Box (Socket) Describes the sockets to be mounted on
the 12701A.


C-1*
12701ATest Fixture Operation Manual
Table of Contents
1. Introduction.............................................................................................................................1-1
1.1 Product Overview.........................................................................................................................1-1
1.2 Supplied Accessories....................................................................................................................1-2
1.3 Optional Accessories ....................................................................................................................1-3
1.4 Environmental Conditions............................................................................................................1-5
1.5 Cleaning, Storage and Transportation of the Product...................................................................1-6
1.5.1. Cleaning................................................................................................................................1-6
1.5.2. Storage ..................................................................................................................................1-6
1.5.3. Transportation.......................................................................................................................1-6
2. Panel Descriptions................................................................................................................2-1
2.1 Relay Terminals............................................................................................................................2-1
2.2 Rear Panel.....................................................................................................................................2-3
3. Measurement Examples.....................................................................................................3-1
3.1 High Resistance Measurement .....................................................................................................3-1
3.2 Resistance Measurement ..............................................................................................................3-6
3.3 Diode Leak Current Measurement..............................................................................................3-12
3.4 Diode Leak Current Measurement..............................................................................................3-17
4. Functional Description.......................................................................................................4-1
4.1 Driving Guard Function................................................................................................................4-1
4.2 Internal Connection ......................................................................................................................4-3
5. Specifications.........................................................................................................................5-1
5.1 Electrical Specifications ...............................................................................................................5-1
5.2 General Specifications..................................................................................................................5-2
Appendix.........................................................................................................................................A-1
A.1 Test Box (Socket)..................................................................................................................................................A-1


F-1*
12701ATest Fixture Operation Manual
List of Illustrations
No. Title Page
2-1 Relay Terminals …………………………………………………………... 2-1
2-2 Rear Panel …………………………………………………...……………. 2-3
3-1 Connecting the 12701A with the 8340A …………………………………. 3-2
3-2 Installing the Test Box…………………………………………………….. 3-3
3-3 Connecting the Relay Terminals with the Test Box ……………………… 3-4
3-4 12701A and 8340A Connection Diagram ………………………………… 3-5
3-5 Connecting the 12701A with the 6245 …………………………………… 3-7
3-6 Connecting the Relay Terminals with the Test Box ……………………… 3-9
3-7 12701A and 6245 Connection Diagram (4-wire Connection) ……………. 3-10
3-8 Connecting the 12701A with the 6245 …………………………………… 3-13
3-9 Connecting the Relay Terminals with the Test Box ……………………… 3-14
3-10 12701A and 6245 Connection Diagram (2-wire Connection) ……………. 3-15
3-11 Connecting the 12701A with the 8252 …………………………………… 3-17
3-12 Connecting the Relay Terminals and the Test Box ……………………….. 3-19
3-13 12701A and 8252 Connection Diagram ………………………………….. 3-20
4-1 Driving Guard Function …………………………………………………... 4-1
4-2 Block Diagram ……………………………………………………………. 4-3

Indice
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione