AddSecure CAT12CE Manuale utente

60206560-100-SE I
AddSecure Smart Rescue AB
CAT12CE
Alarm transmitter
User manual

60206560-100-SE II
AddSecure Smart Rescue AB
No parts of this publication may be copied, redistributed or published by means of photocopying, electronic
copying or retransmission, printing or similar without the written consent of AddSecure Smart Rescue Nordic
AB.
AddSecure Smart Rescue Nordic AB reserves the right to change the publication or the products described in the
publication without prior notice.
All trademarks mentioned in the publication are the property of their respective owners.
Content
1Alarm transmitter CAT12CE .............................................................................................................................................4
1.1 Login............................................................................................................................................................................4
1.2 WEB interface..............................................................................................................................................................5
1.3 WEB interface, main parts...........................................................................................................................................5
2Users ....................................................................................................................................................................6
2.1 Add User......................................................................................................................................................................6
2.2 Change password ........................................................................................................................................................7
2.3 Delete User..................................................................................................................................................................7
3Connections ............................................................................................................................................................8
3.1 Ethernet connection....................................................................................................................................................8
3.2 Connection via GSM ....................................................................................................................................................9
3.3 Connection via Tetra modem....................................................................................................................................10
3.4 Connection of Pocsag................................................................................................................................................11
3.5 Connection via analog phone....................................................................................................................................12
4Alarm receiver .....................................................................................................................................................13
4.1 General information about Alarm Receivers .............................................................................................................13
4.1.1 Alarm via IP / GPRS. SOS Access v4.......................................................................................................................14
4.1.2 SMS message........................................................................................................................................................14
4.1.3 Tetra.....................................................................................................................................................................14
4.1.4 POCSAG ................................................................................................................................................................14
4.1.5 Email.....................................................................................................................................................................14
4.2 Add alarm receiver ....................................................................................................................................................15
4.3 Remove alarm receiver .............................................................................................................................................16
4.4 Alarm Receiver - Configuration .................................................................................................................................16
4.5 Add alarm path..........................................................................................................................................................17
4.5.1 Remove alarm path ..............................................................................................................................................17
4.5.2 Add alarm path IP address....................................................................................................................................18
4.6 E-mail - Configuration................................................................................................................................................19
4.7 SMS - Configuration...................................................................................................................................................20
4.8 Tetra - Configuration .................................................................................................................................................21
4.9 POCSAG Configuration ..............................................................................................................................................22
5Inputs ....................................................................................................................................................................23
5.1 Inputs 1-8 ..................................................................................................................................................................23
5.1.1 Configuration of input status................................................................................................................................25
5.1.2 Balanced input......................................................................................................................................................25
5.2 Input Sabotage ..........................................................................................................................................................26
5.3 Input V22M, SIA Modem...........................................................................................................................................27

60206560-100-SE III
AddSecure Smart Rescue AB
5.4 Input Alarm phone ....................................................................................................................................................28
5.5 Inputs. Tab: Status.....................................................................................................................................................29
5.6 Inputs. Tab: Extension card .......................................................................................................................................30
6Outputs ..............................................................................................................................................................31
6.1 General information about outputs ..........................................................................................................................31
6.2 Output status overview.............................................................................................................................................32
7System. ............................................................................................................................................................33
7.1 System. Tab: System..................................................................................................................................................33
7.2 System. Tab: System RS232 / RS485..........................................................................................................................35
7.3 System. Tab: Shared In/Out.......................................................................................................................................42
7.4 System. Tab: Time .....................................................................................................................................................43
7.5 System Tab: Configuration ........................................................................................................................................44
8Information ...........................................................................................................................................................45
8.1 Information. Tab: Info ...............................................................................................................................................45
8.2 Information. Tab: Event Log......................................................................................................................................46
9Software upgrade ..............................................................................................................................................47
10 SMS management..........................................................................................................................................................48
10.1 SMS messages...........................................................................................................................................................48
11 Document history...........................................................................................................................................................50
11.1 Audits ........................................................................................................................................................................50
11.2 Relaterade dokument................................................................................................................................................50
12 Notes................................................................................................................................................................................1

60206560-100-SE Sid: 4/51
AddSecure Smart Rescue
1ALARM TRANSMITTER CAT12CE
1.1 Login
Configuration for the ethernet connection on PC
to connect to - CAT12CE.
Click Start, type in the search box:
View network connections and click the icon.
Double-click Local Area Connection -
Properties - Internet protocol version 4.
Select Use the following IP address.
Fill in IP: 192.168.1.10
Subnet Mask:255.255.255.0
Press OK.
Now you can connect a network cable between the PC
and CAT12CE for programing via the WEB interface.
To configure alarm terminal CAT12 CE, a WEB interface is used located at the URL http://<CAT12CE ip address>.
(The default ip address is 192.168.1.100).
After the user enters this address in the WEB browser, a logon dialog opens with the following appearance:
Note: This window also opens automatically when the user resets or upgrades the device.
To access the alarm terminal object window, a User Name and password Lösenord must be entered.
Note: The alarm terminal comes with the following standard username and password, admin or admin..
These are used at the first login to the alarm terminal and are recommended to be deleted after the first new
user has been created and verified.
When approved User Name and Password are entered and the login is pressed, an information message is
displayed:
Successfully logged in, redirecting to main page.
If incorrect name or password has been entered, you receive the following error message:
Wrong username or password
If web interface access is not available within 5 minutes, session timeouts occur and you receive the following
error message:
Session timed out / not authenticated. Redirecting to login page

60206560-100-SE Sid: 5/51
AddSecure Smart Rescue
1.2 WEB interface
1.3 WEB interface, main parts
The WEB interface contains two main parts, on the right there is a menu to enter the different settings pages of
the alarm terminal and on the left is shown the content of the settings pages. The following buttons are in the
picture:
If the mouse pointer is transferred over any of the blue texts (the arrow switches to hand) alongside the slides,
you'll see quick information about what the button means.
•Flags - Used to select languages.
•Users - Add/change users.
•Connections - Settings of connection parameters.
•Alarm receiver - Configuration of alarm receivers.
•Inputs - Configuration of the alarm terminal inputs.
•Outputs - Configuration of the alarm terminal relay
outputs.
•System - Setting functions for sms-passwords, RS232
ports, etc.
•Info - Display of the status of the alarm terminal and event
log
•Upgrade - Software upgrade.
•Logoff - Exit of the web application.
In addition to these buttons, two buttons may appear on the
interface pages.
•OK - When the user wants changes made to be
saved/implemented, he clicks on this
button.
•Cancel - When the user does not want changes made to be
saved, he clicks on this button.

60206560-100-SE Sid: 6/51
AddSecure Smart Rescue
2USERS
This window is used to configure/change user and password settings.
•Logged in user - Currently logged in user
•Change password - This button opens a dialog in which logged-in users can change their password.
•Users - A list showing the user names created.
•Add User - This button opens a dialog for creating a new user (see next paragraph).
2.1 Add User
Any user can create additional users. A user account is used to change settings in the alarm terminal, create and
change passwords, etc.
To create a user account, the following steps must be completed:
1. Fill in the User Name field
2. In the Password field, type a new password
3. To confirm the new password, type it in the Password field again.
4. Click OK.
5. After a new user is created, you receive the following informational message:
User <name> successfully added

60206560-100-SE Sid: 7/51
AddSecure Smart Rescue
2.2 Change password
To change an already created user account, the following steps are performed:
1. Fill in the User Name field on the account.
2. In the Old Password field, type the old password.
3. To confirm the new password, type it in the Password field again.
4. Click OK. A dialog indicates that the password has been changed.
Password for user <user name> successfully changed
After the new password is saved, this can be used for authentication when the WEB page is to be opened the
next time. Please note that the user name and password supplied with the alarm terminal should be avoided.
2.3 Delete User
When a created user is to be removed from the terminal, click the delete icon to the right of the user name.
A window for acknowledging the deletion opens and you can press Ok to confirm deletion of the user, or Cancel
to abort the deletion.
Removal is confirmed by pressing OK. A dialog indicates removed user with text:
User <user name> removed
If you try to remove logged-in users, you receive the following error message:
Cannot remove currently logged user

60206560-100-SE Sid: 8/51
AddSecure Smart Rescue
3CONNECTIONS
Alarm terminal CAT12 CE can be connected to alarm receivers with two different alarm routes, primary and
secondary alarm path. The primary alarm route normally means that alarms are transmitted via Ethernet and
the secondary alarm route that alarms are transmitted via GSM modem.Secondary emergency route (back-up
route) is the route used when the primary connection is out of order.
When the WEB interface for connections is opened, the use of the drop-down menu to select the type of
connection in the Ansl via field.
3.1 Ethernet connection
The settings that can be made on this page refer to the indication of the IP address, Subnet Mask, and Standard
Gateway, Number of Retries, and Timeout..
Settings - Ethernet
•IP Address - The alarm terminal own IP address. The radio buttons select whether the addresses should be obtained
via DHCP or if static IP address should be used. (Note: The default setting is 192.168.1.100 when selecting a static IP
address.)
•Subnet mask - Subnet mask used to divide an IP address range into a number of subnets. (Used only for static IP
address)
•Default Gateway address - The network address used as a connection point when connecting to other networks.
(Used only for static IP address)
•Number of retries - Number of retries in case of failed connection, 2 retries are recommended and set by default.
If alarms cannot be transmitted, the queue is saved and sent as soon as CAT12CE has contact with the receiver again
•Timeout - Waiting time between retries if the alarm terminal does not receive receipt on sent alarm. The default and
recommended time is 10 seconds.
•Save –Saving changes for the page. If the button is not affected before the page is left, the changes are not saved.

60206560-100-SE Sid: 9/51
AddSecure Smart Rescue
3.2 Connection via GSM
When the WEB page for connections is opened, select in Interface using the GPRS drop-down menu.
•APN - Name - The name of the access point via GSM data.
AddSecure Link Telia mobiflex.ts.m2m
AddSecure Link, up to 1 GB: mobiflex.tele2.m2m
AddSecure Link, over 1 GB: mobiflex.4g.tele2.m2m
Maingate open network: maingate.telia.se
Maingate end network: maingatelan.telia.se
Maingate 500mb net: mg500mb.tmhlan7
Telia: online.telia.se
Tele2: internet.tele2.se
Telenor: internet.telenor.se
•Username - Used in conjunction with passwords to access the GPRS network. The name may be empty if it is not
specified for used SIM cards.
•Password - Used in conjunction with user name for access to the GPRS network. The name may be empty if it is not
specified for used SIM cards.
•PIN - Enter the SIM card PIN if used. The Sim card can be put in regular mobile phone to turn off pin control, not used
pin control, the field can be left blank.
•Advanced - Opens dialog for the indication of SMSC numbers and selection of network technology to use.

60206560-100-SE Sid: 10/51
AddSecure Smart Rescue
•Number of retries - The number of retries in case of failed transmission, 2 retries are recommended and set by
default.
•Timeout - Waiting time between retries if the alarm terminal does not receive receipt on sent alarm. Adjustable time
at least 40 seconds. The recommended time is 40 seconds. If alarms cannot be transmitted, it is saved in a queue and
sent as soon as CAT12CE has contact with the receiver again.
•Network status - Name of connected GSM Operator - Connected IP address - Signal level and Modem function, etc., i
s displayed in the middle part of the image when GPRS connection is established.
3.3 Connection via Tetra modem
If a Tetra modem is used to send alarms to Tetra terminals, you can see the status of the modem on this page.
•Service center Service Center number used to send message to MSISDN number
•Modem's ISSI TC8000 modem fixed number in the Tetra network
•Modem model Model of radio in the TC8000 modem
•Fw... Radio software version
•Number of retries the number of times CAT12CE will try to send a message if it does not succeed the first time
•Timeout between retries
Indice
Altri manuali AddSecure Trasmettitore