1. PREFACE
2. NAMEPLATE
3. SPECIFICATION
4. DIMENSIONS
5. ENVIRONMENTAL REQUESTS
6. FUNCTION DESCRIPTION .
7. OPERATION AND CONNECTION
8. Motor T-N curve
9. APPLICATION
10. TROUBLE SHOOTING
11. REPAIRING AND MAINTENANCE
Appendix
1
5
6
8
11
13
21
63
64
65
67
70

1. Preface
This D305 drive and brushless servomotor made by ADLEE
Powertronic., Ltd.
Read this instruction manual throughly before operation.
This manual will be helpful in the installation, parameter setting
and troubleshooting of the BLDC motors and drives. To guarantee
safe operation of the equipment, read the following safety guide-
lines before connecting power to the drives. Keep this operating
manual handy and distribute to all users for reference.
Safety Precaution - Read These First
Indicates a potentially hazardous situation which, if against, may
result in personal injury, fire or damage to equipment.
DANGER
Do not install or operate motor or drive that are
damaged or has missing parts.
CAUTIION
Before installation, check specifications are
matched the equipment. Ex. voltage, power,
torque, RPM...
!
Receiving
!
!
Dangerous Electrical Shock
Danger and Caution
1

℃
2
Installation
!
!
!
℉
CAUTION
Impacts and shocks applied to the shaft end will
damage the rotary sensor and ball bearings. Pay
more attention when drive elements such as
pulleys, clutch disks, toothed wheels etc.
DANGER
Be sure to install the unit on flame-resistant material
such as a steel plate. Otherwise, there is the
danger of fire.
DANGER
Install units into a flowing air environment. See
inside manual requests. When mounting units in an
enclosure, install a cooling device to keep the
intake air temperature below 45 (115 ).
DANGEROUS ELECTRICAL VOLTAGE
Due to the permanent magnet excitatiion, the power
connector carries a hazardous high voltage if the
rotor is rotating and the motor is not electrically
connected. The unit must be completely
de-energized and halted before commencing any
connection or installation work.
CAUTION
Wiring should be performed only by qualified
personnal.
DANGER
For equipment protection, install a ground leakage
type breaker with a fast response circuit capable of
handling large currents.
Wiring
!
!

CAUTION
Hazardous terminals for any interconnection (motor,
contact breaker, filter, etc.) must be inaccessible in
the final installation.
DANGEROUS ELECTRICAL SHOCK
Be sure that the input voltage is matched the drive
specifications.
DANGEROUS ELECTRICAL SHOCK
Be sure not to connect an AC power supply to the
output terminals.
DANGEROUS ELECTRICAL SHOCK
Be sure to connect the grounding terminal to earth
ground. Ground resistance is less than 100 .
DANGEROUS ELECTRICAL SHOCK
Never remove connectors by pulling on its wire
leads. Otherwise, there is a danger of fire or injury
due to wire breakage.
CAUTION
Do not stop operation by switching of
electromagnetic contactors on the primary.
CAUTION
Tighten terminal screws.
CAUTION
When using D305 drives should match to
ADLEEPOWER®AM series motors. If using other
brand motors can cause the driver or motor dam-
age.
!
3
Ω
!
!
!

CAUTION
Danger of getting burnt! The surfaces of motors can
reach temperatures of up to approx. 100 (212 ).
A touch guard is to be provided where necessary.
DANGER
Danger of injury from shaft keys being slung out.
Motor may only be operated as installed.
CAUTION
Since it is easy to change operation direction or
speed from low to high speed. Verify the safe
working range of the equipment.
DANGEROUS ELECTRICAL SHOCK
To wait at least five minutes after turning off the
input power supply before performing maintenance
or an inspection. Otherwise, there is the danger of
electric shock.
DANGEROUS ELECTRICAL SHOCK
Never test the withstand voltage(HIPOT) on the
drive. It may cause components to be damaged.
DANGEROUS ELECTRICAL SHOCK
Never modify the unit. Otherwise, ther is danger of
electric shock and/ or injury.
℃
℉
Operation
Maintenance and Inspection
4
!
!
!

2. Nameplate
Motor
Drive
D305 ( B ) - 1
: With B : with magnet brake
: 1 : 110Vac : input source voltage 110Vac, output 220Vac
2 : 220Vac : input source voltage 220Vac, output 220Vac
j k
j
k
AM - XXX L (B)
: Rated power : example 370 represent 370W
: Rated speed : L : 2000RPM M : 3000RPM H : 6000RPM
: With B : with magnet brake
j k l
j
k
l
5
200~230V 50/60Hz
SINGLE PHASE 3.8A
AC-INPUT
Model:D305
ADLEE POWERTRONIC CO., LTD.
BLDC DRIVE
ADLEEPOWER
AC-OUTPUT
0~230V 3PHASE
180W 2.2A
DATE:
RManufacturing date
Rated Output power &
Output Voltage & PhaseInput Voltage & Frequency
Input phase & Max. Input
Model No.
Current Max. Current
ADLEEPOWER
Brushless DC Motor
ADLEE POWERTRONIC CO., LTD.
Model
Volts
AMP.S
AMB
Max. rpm
IP
Output
INS.
DRIVE
DATE
AM-180L
AC220V
0.55
45°C/113°F
2000
180W
40
B
R
Manufacturing date
Drive model
Implied protection
Rated powerModel No.
Input voltage
Rated current
Ambinent Temp
Max. rpm
Insulation grade
D305

3. Specification
6
Model No. AM-60
L/M AM-90
L/M/H AM-120
L/M/H AM-180
L/M/H AM-250
L/M/H AM-370
L/M/H
Input Voltage 100~130VAC / 1ψ OR 200~230VAC / 1ψ (TN system)
Input Frequency HZ 50 / 60
Input Rated Current A 0.7 1.1 1.5 2.1 2.9 3.6
Max. Input Current A
(For 220V input) 2.8 3.4 4.2 56.5 8.5
Max. Input Current A
(For 110V input) 5.6 6.2 7.3 10 11.6 15
Output Rated Current A 0.4 0.6 0.8 1.1 1.6 2.2
Max. Output Current A 1.8 22.4 3.2 4.1 4.9
Overload Current
Protection (A) 2.0/2.4 2.4/2.4/2 2.6/3.2/3.0 3.6/4.4/3.5 5.0/5.6/5.0 6.4/6.6/6.4
Motor Rated Current A 0.32/0.34 0.45/0.45/0.43 0.61/0.64/0.52 0.94/0.94/0.78 1.45/1.15/1 1.92/1.7/1.4
Motor Phase 3ψ
Rated Output W 60 90 120 180 250 370
Rated Torque Kg-cm
(in-lb) 2.9/2.0
(2.5/1.7) 4.4/2.9/1.5
(3.8/2.5/1.3) 5.8/3.9/2.0
(5.0/3.4/1.7) 8.8/5.8/2.9
(7.6/5.0/2.5) 12.0/8.1/4.0
(10.4/7.0/3.5) 18.0/12.0/6.0
(15.6/10.4/5.2)
Rated Speed RPM L:2000 / M:3000 / H:6000
Max. Efficiency % > 80 > 80 > 80 > 80 > 80 > 80
Max. Output W 180 220 280 330 450 600
Max. Torque Kg-cm
(in-lb) 12/6
(10.4/5.2) 15/9/5.5
(13.0/7.8/4.8) 18/12/8
(15.6/10.4/6.9) 27/18/10.5
(23.4/15.6/9.1) 36/24/13
(31.2/20.8/11.3) 54/36/20
(46.8/31.2/17.3)
Variable Speed Range RPM L:150~2000 / M:150~3000 / H:300~6000 / HX1:130~5000 / HX2:300~9999
Acc. Dec. Time Around 0.2 ~ 600 Sec / Max. 45dB (L Model)
The magnet brake torque is 25Kg-cm (21.65 in-lb).
The varnished copper wire is F class insulation.
110V/1 Max. input current is approximately double in above table.
※ ∮
※ ∮
※ ∮
ψ

7
Model No. AM-60
L/M AM-90
L/M/H AM-120
L/M/H AM-180
L/M/H AM-250
L/M/H AM-370
L/M/H
Speed
regulation
Load ±1% Below (0~Rated Torque at rated speed)
Voltage ±1% Below (Source voltage±10% at rated speed No Load)
Temperature ±1% Below (0~40℃ / 32~104℉ at rated speed No Load)
Motor Insulation/
Max. Working TEMP. ※ B Class ( 130℃/266℉ ) / Max. 100℃/212℉
Type of control Rectangular wave PWM
Speed command Built-in potentiometer / External Potentiometer ≧ 2 kΩ / RS-485
Operation
1. Remove control pannel : CW, CCW, STOP Key
2. Terminal : Type of input : Photocoupler, input impedance 2.2kΩ / CF, CW, CCW, SLOW DOWN
Common
3. Communication : RS-485
Output signal Open collect output, External use condition 5VDC、10mA below
SPEED OUT、ALARM OUT
Protection
Any phenomenons as below, motor will stop and output alarm signal.
●Over load:Motor working temperature is not over 120℃(248℉).
●Over heat:Power D305 model over heat 120℃(248℉) shut down itself. ※110℃(230℉) Reset.
●Lost phase:Motor signals are abnormal, due to motor cables was broken or discounector.
●Phase to phase short circuit.
Environmental Enclosure
Rating IP20
Protective Class I
Figure No. 1 1 2(L/M) 1 3(L/M) 2 45 4(M/H)
Motor Weight Kg
(lb) 2.1/2.1
(4.62/4.62) 2.4/2.4/2.4
(5.28/5.28/5.28) 2.6/2.5/2.5
(5.72/5.50/5.50) 2.9/2.7/2.7
(6.38/5.94/5.94) 4.0/3.8/3.7
(8.8/8.36/8.14) 4.5/4.5/4.0
(9.90/9.90/8.80)
D305 Driver Weight Kg
(lb) 0.75
(1.65) 0.75
(1.65) 0.75
(1.65) 0.75
(1.65) 0.8
(1.77) 0.8
(1.77)

4. Dimensions
4-1 Motor dimensions
Unit : mm
Lead cable length : 1M (3.28ft)
8
No. PM∮S∮N∮TLA LB L1 L2 AD AB1 B2 Output Shaft End
ED QED∮GA F
1
90 104 8.5 83 2.5 8
99.5 127.5 160.5
109.8 28.5 61 33
20 25 28 12 13.5 4
2114.5 146.5 179.5
25 29 32
3
14 16 54 169.5 201.5 234.5
5184.5 216.5 249.5
□
Questo manuale è adatto per i seguenti modelli
16
Indice
Altri manuali Adleepower Azionamento CC
Manuali Azionamento CC popolari di altre marche

Vincent Associates
Vincent Associates UNIBLITZ ED12DSS Manuale utente

EKSMA OPTICS
EKSMA OPTICS DQ-100-4 Manuale elenco delle parti

Chamberlain Garog
Chamberlain Garog D Series Manuale utente

Parker
Parker PDS Series Manuale utente

Festo
Festo DGC G Series Guida all'installazione

Binks
Binks QS-5012-1-CE Manuale utente