AJAX Systems GlassProtect Manuale utente

GlassProtect User manual
Updated January 24, 2022
GlassProtect is a wireless indoor glass break detector recognizing the sound of
shattering the glass at a distance of up to 9 meters. GlassProtect can operate
up to 7 years from a pre-installed battery and has a socket for connecting a
third-party wired detector.
GlassProtect connects to the Ajax security system via the protected
radio protocol. The communication range is up to 1,000 meters in line of sight.
Also, GlassProtect can be connected to third-party security systems using the
or integration modules.
Users can congure GlassProtect via the for macOS, Windows, iOS, or
Android. The system noties users of all events through push notications, SMS,
and calls (if activated).
The user can connect the Ajax security system to the central monitoring station
of a security company.
Jeweller
Ajax uartBridge Ajax ocBridge Plus
Ajax app
Buy breakage detector GlassProtect

Functional elements
Operating Principle
GlassProtect uses a sensitive electret microphone to detect the sound of glass
breaking, consisting of a low-frequency hit sound and high-frequency crashing
sound of glass shatters. Such two-stage glass break detection decreases the
risk of false triggering.
GlassProtect detector does not react to the breaking of the lm-covered glass:
shockproof, sunscreen, decorative, or any other type of lm. To detect the breaking of
1. LED indicator
2. Microphone hole
3. SmartBracket attachment panel (perforated part is required for actuating
the tamper in case of any attempt to dismantle the detector. Don’t break it
out!)
4. External detector connection socket
5. QR code
6. Device switch
7. Tamper button

such kind of glass, we recommend using the wireless opening detector
with shock and tilt sensors.
If triggered, GlassProtect immediately transmits the alarm signal to the ,
activating the (if connected) and notifying the user and security company.
Connecting
Detector Connection to hub
Before starting connection:
Only users with administrator rights can add the device to the hub.
Pairing the detector with hub:
DoorProtect Plus
hub
sirens
1. Following the hub user guide, install the . Create the account, add
the hub, and create at least one room.
Ajax app
2. Switch on the hub and check the internet connection (via Ethernet cable
and/or GSM network).
3. Make sure that the hub is disarmed and does not update by checking its
status in the Ajax app.
1. Select Add Device in the Ajax app.
2. Name the device, scan or type the QR code (located on the detector body
and packaging), and select the location room.

For detection and pairing to occur, the detector should be located within the
coverage area of the wireless network of the hub (at a single protected object).
The connection request is transmitted for a short time: at the moment of
switching on the device.
If the device failed to pair (LED blinks once per second), switch it off for 5
seconds and retry. The detector connected to the hub appears in the list of
devices in the app. The update of the detector statuses in the list depends on
the device ping interval set in the hub settings (the default value is 36 seconds).
3. Tap Add — the countdown will start.
4. Switch on the device.

Connecting to Third-Party Systems
To connect the detector to a third-party central unit using the or
integration module, follow the recommendations in the user
manual of the respective device.
States
The states screen contains information about the device and its current
parameters. Find the GlassProtect states in the Ajax app:
Parameter Value
Temperature
Temperature of the detector, measured on the
processor and changes gradually.
Acceptable error between the value in the app
and temperature at the installation site: 2–4°C
Jeweller Signal Strength
Signal strength between the hub/range
extender and the opening detector.
We recommend installing the detector in places
where the signal strength is 2–3 bars
Connection
Connection status between the hub/range
extender and the detector:
ReX range extender name Displays the status of using a
Battery Charge Battery level of the device. Displayed as a
percentage
uartBridge
ocBridge Plus
1. Go to the Devices tab.
2. Select GlassProtect from the list.
Online — the detector is connected with the
hub/range extender
Oine — the detector has lost connection
with the hub/range extender
radio signal
range extender

Lid The tamper state, which reacts to the
detachment of or damage to the detector body
Delay When Entering, sec
Entry delay (alarm activation delay) is the time
you have to disarm the security system after
entering the room.
Functions for the connected wired detector
only.
Delay When Leaving, sec
Delay time when exiting. Delay when exiting
(alarm activation delay) is the time you have to
exit the room after arming the security system.
Functions for the connected wired detector
only.
Night Mode Delay When Entering, sec
The time of Delay When Entering in the Night
mode. Delay when entering (alarm activation
delay) is the time you have to disarm the
security system after entering the premises.
Functions for the connected wired detector
only.
Night Mode Delay When Leaving, sec
The time of Delay When Leaving in the Night
mode. Delay when leaving (alarm activation
delay) is the time you have to exit the premises
after the security system is armed.
Functions for the connected wired detector
only.
Sensitivity Selecting the sensitivity level of the
microphone:
How battery charge is displayed in
Ajax apps
What is delay when entering
What is delay when leaving
What is delay when entering
What is delay when leaving

The sensitivity level is selected based on the
results of the
External contact Status of the external detector connection to
GlassProtect
Always Active
If the option is active, the detector is always in
armed mode and noties about alarms
Chime
When enabled, a siren noties about opening
detectors triggering in the Disarmed system
mode
Temporary Deactivation Shows the status of the device temporary
deactivation function:
Low
Normal
High
detection zone test
Learn more
What is chime and how it works
No — the device operates normally and
transmits all events
Lid only — the hub administrator has
disabled notications about triggering on
the device body
Entirely — the device is completely excluded
from the system operation by the hub
administrator. The device does not follow
system commands and does not report
alarms or other events
By number of alarms — the device is
automatically disabled by the system when
the number of alarms is exceeded (specied
in the settings for Devices Auto
Deactivation). The feature is congured in
the Ajax PRO app
By timer — the device is automatically
disabled by the system when the recovery
timer expires (specied in the settings for
Devices Auto Deactivation). The feature is
congured in the Ajax PRO app

Firmware Detector rmware version
Device ID Device identier
Device No. Number of the device loop (zone)
Settings
To change the detector settings in the Ajax app:
Setting Value
First eld
Detector name that can be changed. The name
is displayed in the text of SMS and notications
in the event feed.
The name can contain up to 12 Cyrillic
characters or up to 24 Latin characters
Room
Selecting the virtual room to which
GlassProtect is assigned. The name of the
room is displayed in the text of SMS and
notications in the event feed
Delay When Entering, sec
Selecting delay time when entering. Delay when
entering (alarm activation delay) is the time you
have to disarm the security system after
entering the room.
Functions for the connected wired detector
only.
1. Select the hub if you have several of them or if you are using the PRO app.
2. Go to the Devices tab.
3. Select GlassProtect from the list.
4. Go to Settings by clicking on the .
5. Set the required parameters.
6. Click Back to save the new settings.
What is delay when entering

Delay When Leaving, sec Selecting the delay time when exiting. Delay
when exiting (alarm activation delay) is the time
you have to exit the room after arming the
security system.
Functions for the connected wired detector
only.
Arm in night mode If active, the detector will switch to armed mode
when using Night mode
Night Mode Delay When Entering, sec
The time of Delay When Entering in the Night
mode. Delay when entering (alarm activation
delay) is the time you have to disarm the
security system after entering the premises.
Functions for the connected wired detector
only.
Night Mode Delay When Leaving, sec
The time of Delay When Leaving in the Night
mode. Delay when leaving (alarm activation
delay) is the time you have to exit the premises
after the security system is armed.
Functions for the connected wired detector
only.
Alarm LED indication
Allows you to disable the ashing of the LED
indicator during an alarm. Available for devices
with rmware version 5.55.0.0 or higher
Sensitivity Selecting the sensitivity level of the
microphone:
What is delay when leaving
What is delay when entering
What is delay when leaving
How to nd the rmware version or
the ID of the detector or device?
Low
Normal
High

The sensitivity level is selected based on the
results of the
External contact If active, GlassProtect registers external
detector alarms
Always Active
If the option is active, the detector is always in
armed mode and noties about alarms
Alert with a siren if an external contact is open If active, added to the systemare
activated in case of an external detector alarm
Alert with a siren if glass break detected If active, added to the systemare
activated when the glass break detected
Chime settings
Opens the settings of Chime.
Jeweller Signal Strength Test
Switches the detector to the Jeweller signal
strength test mode. The test allows you to
check the signal strength between the hub and
GlassProtect and determine the optimal
installation site
Detection Zone Test
Switches the detector to the detection area test
Signal Attenuation Test
Switches the detector to the signal fade test
mode (available in detectors with rmware
version 3.50 and later)
User Guide Opens GlassProtect User Guide in the Ajax app
Temporary Deactivation Allows the user to disconnect the device
without removing it from the system.
detection zone test
Learn more
sirens
sirens
How to set Chime
What is Chime
What is Jeweller Signal Strength
Test
What is Detection Zone Test
What is Attenuation Test
Indice
Altri manuali AJAX Systems Sensore di sicurezza

AJAX Systems
AJAX Systems DoorProtect Manuale utente

AJAX Systems
AJAX Systems MotionProtect Outdoor Manuale utente

AJAX Systems
AJAX Systems DoorProtect Plus Manuale utente

AJAX Systems
AJAX Systems DoorProtect Manuale utente

AJAX Systems
AJAX Systems MotionCam Manuale utente

AJAX Systems
AJAX Systems Hub Plus Manuale utente

AJAX Systems
AJAX Systems StreetSiren Manuale utente

AJAX Systems
AJAX Systems MotionCam Manuale utente