5/33
ALFA IN a.s. © www.alfain.eu
MACHINE PROTECTION
This machine is electronically protected against overload. Do not turn off the
main power switch while the machine loaded.
ACL-10 coolant is designed for ambient temperatures up to -10˚C.
Notice
Persons with implanted pacemakers must not operate the machines or move in
close proximity to them! There is a risk of impaired pacemaker function!
3 OPERATING CONDITIONS
1. The commissioning of the instrument may only be carried out by trained
personnel and only within the technical provisions. The manufacturer is not
liable for damage caused by improper use and operation. Only use original
ALFA IN spare parts for maintenance and repair.
2. The device complies with EN 61000-3-12 under the following conditions:
The short-circuit power of the Ssc network at the interface between the user
supply and the public power supply (PCC) shall be at least 4106 kW.
The user is obliged to consult with the electricity supplier whether the
impedance of the network at this location corresponds to the required
value of short-circuit power Zmax = 36 mΩ and whether the device can be
connected to the public low-voltage network.
The following symbols appear on the machine's nameplate: .
3. The welding machine can be manipulated using the crane eyes that are
part of the chassis. The machine can only be handled if it is attached by
all crane eyes. It is forbidden to transport the SVAROG using the eyes if
a gas cylinder is placed on the platform.
4. The welding machine is tested according to the standard for protection
class IP 23S, which provides protection against the ingress of solid bodies
with a diameter greater than 12 mm and against the ingress of water falling
in a vertical to oblique direction up to an inclination of 60°.
5. Operating ambient temperature between -10 and +40 °C.
6. Relative humidity below 90% at +20 °C.
7. Up to 3000 m above sea level.
8. The machine must be positioned in such a way that cooling air can enter
and exit through the cooling vents without restriction. Care must be taken
to ensure that no mechanical particles, especially metal particles (e.g.
during grinding), are drawn into the machine.
9. The handling handle is designed for travelling only, it is not designed for
lifting the machine.
10. If the machine overheats, welding is automatically interrupted and this
condition is indicated by a light.
11. All interventions in the el. equipment, as well as repairs (removal of the
mains plug, replacement of fuses) may only be carried out by an authorised
person.