B2 HVA Series Manuale utente

HVA Family
HVA28 | HVA34-1 | HVA45
and corresponding TD models
User Manual
Ultra-compact, universal
VLF High Voltage Testing Set with Tan Delta
Firmware V2
ENGLISH
DHV0086 Rev06
b2 electronic GmbH
Riedstrasse 1
6833 Klaus
Austria
T +43 (0) 5523 57373
F + 43 (0) 5523 57373-5
www.b2hv.at
info@b2hv.at
Subject to alterations.
Errors excepted.
Illustrations are not binding.
ZERTIFIZIERT
TÜV AUSTRIA CERT GMBH
EN ISO 9001
ZERTIFIKAT NR. 20 100 92003758

© b2 electronic GmbHDHV0086 Rev062

© b2 electronic GmbH DHV0086 Rev06 3
Table of Contents
1 Introduction �����������������������������������������������������������������������������������4
1.1 About this Document.......................................................................4
1.2 Documentation Conventions ...........................................................5
1.3 Legal Considerations.......................................................................7
2 Safety����������������������������������������������������������������������������������������������8
2.1 General Safety ................................................................................8
2.2 Work Safety.....................................................................................8
2.3 Appropriate Applications................................................................10
2.4 OperatorQualications..................................................................10
3 General Description �������������������������������������������������������������������� 11
3.1 TechnicalSpecications ................................................................ 11
3.2 Design Features............................................................................14
3.3 External Interlock and Control ......................................................15
3.4 Materials........................................................................................16
4 Design and Construction������������������������������������������������������������18
4.1 Control Elements...........................................................................18
4.2 User Interface................................................................................20
4.3 Instrument Setup...........................................................................25
4.4 Operation Modes...........................................................................32
5 Test Procedure ����������������������������������������������������������������������������36
5.1 Equipment setup ...........................................................................36
5.2 Manual Test Mode .........................................................................40
5.3 Automatic Test Mode.....................................................................55
5.4 Interrupting a Test..........................................................................73
5.5 Discharge Status...........................................................................74
6 Tan Delta ��������������������������������������������������������������������������������������75
6.1 Application.....................................................................................75
6.2 Equipment Setup...........................................................................76
6.3 Tan Delta Test................................................................................82
6.4 PC Software ..................................................................................86
7 Reporting �������������������������������������������������������������������������������������87
7.1 Report Type...................................................................................87
7.2 Report Activation ...........................................................................87
7.3 Report Naming Instructions...........................................................88
7.4 Manage Reports............................................................................90
8 Disconnection Procedure�����������������������������������������������������������96
8.1 Disconnection Diagram - Normal Conditions ................................96
8.2 Disconnection Diagram - System Failure......................................98
9 Instrument Care�������������������������������������������������������������������������100
10 Accessories �������������������������������������������������������������������������������101
11 Glossary and Abbreviations����������������������������������������������������102
12 Declaration of Conformity ��������������������������������������������������������104

Introduction
© b2 electronic GmbHDHV0086 Rev064
1 Introduction
Purpose
The purpose of this manual is to ensure the proper and safe use of the HVA28,
HVA28TD, HVA34-1, HVA34TD-1 HVA45 and HVA45TD testing instruments.
1�1 About this Document
Devices
This document applies the corresponding HVA smart VLF units.
HVA refers to HVA28, HVA28TD, HVA34-1, HVA34TD-1, HVA45 and HVA45TD.
Target Users
This user manual is designed to inform various user groups. The scope
and depth of the information provided may not be appropriate for all users.
However, it is important that all users familiarize themselves with this
documentinfull.Thefollowingisaguidelineindicatingthemostsignicant
information as a function of the user’s responsibilities.
User Responsibilities Focus
HVA operator • Connecting the equipment
• Carrying out manual or pre-programmed test
sequences
• Verifying the validity of a HVA application
• Adjusting instrument settings
• Programming automatic test sequences in
accordance with particular testing standards
All sections
Particular focus on all
safety messages
Procurement,
management
• Assuring that the workplace is safe and has all
required equipment
• AssuringthatHVAoperatorsarequaliedtech-
nicians
• Assuringthatoperatorsfulltheirresponsibilities
Particular focus on
safety messages and
information regarding
general product
description.
Safety
NOTICE
This manual should always be on hand when using the HVA testing
instruments.

Introduction
© b2 electronic GmbH DHV0086 Rev06 5
1�2 Documentation Conventions
This chapter explains the symbols and safety messages in this document.
Safety symbols and signal words are used in accordance with the American
National Standards Institute standard ANSI Z535.6 „Product Safety Signs and
Labels“.
Safety Messages
Danger DANGER
Indicates a hazardous situation which, if not avoided, will result in death
or serious injury.
Warning WARNING
Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
Caution CAUTION
Indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
Notice NOTICE
Indicates suggested practices to protect equipment and property.
Safety Messages
A detailed symbol, yellow triangle, framed in black: Used to indicate a
potential hazard.
Only used in conjunction with description of the possible hazard!
Detailedsymbolmaycorrespondtoaspecichazard.
Circle outlined in red with red diagonal line: Used to indicate forbidden
practices.
The practice described must not be carried out!
Blue circle with white exclamation mark: Used to indicate recommended
precautionary measures or a situation that can lead to property damage.

Introduction
© b2 electronic GmbHDHV0086 Rev066
b2 Customer Portal – customers�b2hv�com
Register now and gain access to quick and comprehensive support and the
product data base.
The b2 Customer Portal is exclusively reserved for b2 electronic customers.
Register now for:
• Information about meetings and training sessions
• Documents and manuals
• Newsoftwareorrmwareversions
• Support and service request tools
• Messaging
• Newsletters at your request

Introduction
© b2 electronic GmbH DHV0086 Rev06 7
1�3 Legal Considerations
Warranty
b2 provides a one-year warranty from the original purchase date of the
instrument on all necessary parts and labor. This warranty is void in the
event of abuse, incorrect operation or use, unauthorized modication or
repairs,orfailuretoperformthespeciedmaintenanceasindicatedinthis
user manual. This warranty does not include normal consumable items such
as lamps, paper rolls, printer ribbons, batteries or other auxiliary items.
This warranty and our liability are limited to replacing or repairing defective
equipment, at our discretion. Equipment that is returned to b2 must be
packed in original packaging. All shipped items must be prepaid and insured.
No other warranties are expressed or implied.
Contact Information
b2 electronic GmbH
Riedstrasse 1
6833 Klaus
Vorarlberg, Austria
T: +43 (0)5523 57373
F: +43 (0)5523 57373-5
www.b2hv.at
info@b2hv.at
Copyright
© 2017 b2 electronic GmbH
All rights reserved.
No part of this publication may be reproduced, transmitted, stored, or translated
in hard copy or electronic form without the written consent of b2 electronic GmbH.
Your opinion matters!
Your comments and suggestions are of value. We are dedicated to supporting
yourneeds.Oering youoptimaldocumentation ispartofour promiseof
quality.
Improvement suggestions regarding this manual may be sent to:
info@b2hv.at
Thank you for your feedback!

Safety
© b2 electronic GmbHDHV0086 Rev068
2 Safety
Safety is paramount! Respect all safety information; only use the HVA for
appropriate applications and ensure that operators possess the required
2�1 General Safety
NOTICE
User Manual
Before carrying out any high voltage test with this instrument, read this
User manual in its entirety.
2�2 Work Safety
DANGER
Electric Shock Hazard
Never assume that equipment is safe to handle without using the necessary
safety equipment and earthing procedures.
• All procedures must comply with local safety regulations.
• Always treat exposed connectors and conductors as potential electric
shock hazards.
• Device under Test (DUT) must be earthed, de-energized and isolated
from all power sources.
• All auxiliary electrical apparatus such as switchgear, surge arresters
etc. must be isolated from the test power source and the DUT.
• All cables and connectors must be inspected for damage before use.
Damaged equipment must not be used.
• Earthconnectionsmustbemaderstandremovedlast.
• DUT must be discharged and earthed before disconnecting the test
lead.
• Avoid testing alone. In the event of an emergency, another person’s
presence may be essential.

Safety
© b2 electronic GmbH DHV0086 Rev06 9
DANGER
Authorized Personnel Only
Thetestareamustbesecuredtokeepnon-qualiedpersonnelothe
premises!
• Signs must warn all persons of the high voltage test area.
• Onlyqualiedelectricaltechniciansshouldhaveaccesstothetest
area.
• Otherpersonsmustbeaccompaniedbyqualiedelectricaltechnicians
and must be informed of the risks involved.
WARNING
Radiation Hazard
Testing vacuum bottles, above their rated voltage, with DC can produce
dangerous X-rays.
NOTICE
Equipment Handling
DUT must have clean connections.
Testinginstrumentsmustonlyberepairedormodiedbyauthorized
b2 personnel.
NOTICE
If required according to local safety regulations
Wear high voltage gloves when handling high voltage cables and
equipment.
WARNING
This is a class A product. In a domestic environment, this product may
cause technical interference, in which case the user may be required to
take adequate measures.

Safety
© b2 electronic GmbHDHV0086 Rev0610
2�3 Appropriate Applications
The HVA testing instruments is designed to perform high voltage insulation
testing of various types of highly capacitive loads.
Appropriate DUTs
DUT Type Examples
Cables • Extruded cables (e.g. XLPE)
• Laminated cables (e.g. PILC)
• Insulated cables
• Cable jackets/sheaths
Other highly capacitive loads • Generators
• Switchgear
• Transformers
• Rotating machines
• Insulators
• Bushings
Appropriate measurements
Measurement Examples
Test • Capacitance
• Resistance
• Dielectric breakdown voltage
• RMS current
• Applied voltage
NOTICE
Other Applications
Before proceeding, contact b2 to validate appropriate use!
2�4
HVAoperatorsmustbequaliedelectricaltechnicians!Proofofnecessary
qualicationsforworkinginhighvoltagedomainismandatory.Itishighly
recommended that operators have completed an emergency rescue training
programme.
Questo manuale è adatto per i seguenti modelli
6
Indice
Altri manuali B2 Apparecchiature di prova
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione