Button 1: 1. pressed: effect 1 (normal colour change)
2. pressed: effect 5: „LSD“
Button 2: 1. pressed: effect 2 (Soft colour change)
2. pressed: effect 6: Fire „Fire“
Button 3: 1. pressed: effect 3: „Blob“
2. pressed: effect 7: Lightnings „Flash“
Button 4: 1. pressed: effect 4: User colour change
2. pressed: effect 8: „Burst“
Important: Shutdown: if any button is pressed longer than abt. 3 seconds, all modules are switched of,
any further button will start its assigned effects,
The DIP-Switches - Default-Effects
Some settings (i.e. the default effect after reset or power on) can be preset with the internal DIP
switches. For this the case of the module must be opened (see attachment).
Important: Please do not touch any of the electronic components, because off the risk of damage by
electrostatic discharge. We recommend to use a small non-conductive tool to change the DIP
switches.
The switches are separated in 3 groups (as imprinted):
DIP 1,2: These two switches control hold time for effects 1 snd 2 (colour changes):
DIP 1 DIP 2 Effect 1 Effect 2
Off Off 5 sec. 30 sec. (default)
On Off 10 sec. 60 sec.
Off On 30 sec. 120 sec.
On On 90 sec. 180 sec.
DIP 3,4,5: These switches are for the default effect after reset or power on.
DIP 3 DIP 4 DIP 5 Effect
Off Off Off Effect 1: Standard colour change, colour transition time 2.5 seconds (default)
On Off Off Effect 2: Slow colour change, colour transition time 10 seconds (default)
Off On Off Effect 3: Randomly faded colours „Blob“
On On Off Effect 4: User defined olour change (can by changed by PC software
Off Off On Effect 5: Randomly changed colours„LSD“
On Off On Effect 6: Simulation Fire „Fire“
Off On On Effect 7: Simulation Lighnings („Flash“)
On On On Effect 8: Randomly coloured flashes („Burst“)
DIP 6,7,8 determine the „Group“ of a module. Because the modules can be connected as a network, it
should be possible to send command only to a part of the network too. This is what we call a „Group“.
In example if several modules are used for a pool illumination (ceiling, walls under-water), these
modules could be separated into three groups. Now it possible to send command i.e. only to modules
on the ceiling. More information can be found in the following paragraph „A Pool Scenario“..
Another important use of the Groups is the starting colour for the preprogrammed colour changes
after power on or reset: To achieve impressive effects - even without using a network or PC software -
the Groups can be used. Seven different starting colours are available:
DIP 6 DIP 7 DIP 8 Group Starting colour Index of starting colours
Off Off Off (none) Red 1 (Default)
On Off Off Group 1 Green 4
Off On Off Group 2 Blue 7
Chromoflex - Manual - English V1.07 - www.barthelme.de Rev. 02.07.2006
- 8 -