GB Infrared Light Module LM-IR-16-4
10 BEIER-Electronic 28.04.2022
Connection of switch for manual motor control
An optional switch LM-SW can be connected to pin strip X5/6,
with which the motor can be controlled manually. For example,
the trailer supports can be moved without remote control. The
speed of the motor in manual mode is set in the LM-Teacher.
Connection of data cable K-USB-2
The data cable K-USB-2 is connected to the pin header X5/7. The orange cable
points upwards.
The light module is not supplied with voltage via the data cable. If the data cable is to
be used, the LM-IR-16-4 must be supplied with voltage via the battery (as normal).
The data cable is used to transfer and read out the settings of the light module. The
diagnosis can be used to check functions and search for errors. The data cable is
also required for a firmware update.
Road train
An IR transmitter diode can also be connected to pin header X5/7, which then
forwards the received IR signal 1: 1 to another light module. In this way, a road train
can be implemented with several trailers.
Simultaneous operation of the data cable and the IR transmitter diode at X5/7 is not
possible! However, it can be plugged between the data cable and the IR transmitter
diode at any time.
All light modules of the road train always receive the same light signals for the 16
switching outputs. The signals for the 4 servo outputs and the motor output are also
initially identical for all light modules. Using the functions “LM: Activate road train ID
1” - “LM: Activate road train ID 7” on the towing vehicle, however, the servo outputs
and the motor output can be controlled very specifically with just one light module.
The road train ID can be set in the LM-Teacher (see page 17)
If, for example, the "LM: Activate road train ID 2" function is switched on via the
towing vehicle, the commands for the servo outputs and the motor output only affect
the light module that has ID 2. With all other light modules, the servo outputs and
motor outputs remain in the last state.
If no ID is selected on the towing vehicle, the commands for the servos and the
motor output are always carried out by all light modules. This is always the initial
state after switching on.