www.bodine-electric.com 5
1.4 Motor Connection – Wire the motor to Terminal Block TB1 Terminals “U”, “V”, “W”, as
shown in Figure 6 on page 13. (Special reactors may be required for cable lengths over 100
ft. (30 m) – consult our Sales Department.) See Section 5.3 on page 14.
1.5 60 Hz And 50 Hz Motor Operation – The drive is factory set for 60 Hz 3-phase motor opera-
tion (Jumper J5 set to the “60Hz” position). For 50 Hz motor operation, set Jumper J5 to the
“50Hz” position. See Section 6.4 on page 17.
1.6 Start/Stop Switch – The drive is supplied with a pre-wired Start/Stop Switch to electroni-
cally “start” and “stop” the drive, as described in Section 5.5 on page 14. This switch must
be used to “start” the drive each time the AC line is applied to the drive or to “restart” the
drive. Also see Section 6.8 on page 18.
1.7 Jumper Settings – All jumpers have been factory set for most applications, as shown in
Figure 2 on page 9. However, some jumpers may need to be set in order to tailor the drive
for a specific application. See Section 6 on pages 17 – 19.
IMPORTANT: In order to ensure that the motor is properly protected with the I2t Overload
Protection feature, it is required that Jumper J2 is set to the corresponding position for the
motor horsepower being used, as shown in Figure 16 on page 17.
1.8 Trimpot Settings – All trimpots have been factory set for most applications, as shown in
Figure 2 on page 9. Some applications require adjustment of the trimpots in order to tailor
the drive for a specific requirement. See Section 13 on pages 23 – 26.
1.9 Diagnostic LEDs – After power has been applied, observe the LEDs to verify proper drive
operation, as described in Section 12 on page 22.
2 SAFETY WARNING
Definition of Safety Warning Symbols
Electrical Hazard Warning Symbol – Failure to observe this warning could result in electrical
shock or electrocution.
Operational Hazard Warning Symbol – Failure to observe this warning could result in serious
injury or death.
This product must be installed and serviced by a qualified technician,
electrician, or electrical maintenance person familiar with its operation and the hazards
involved. Proper installation, which includes electrical connections, fusing or other current
protection, and grounding, can reduce the chance of electrical shocks, and/or fires, in
this product or products used with this product, such as electric motors, switches, coils,
solenoids, and/or relays. Do not use this drive in an explosion-proof application. Eye
protection must be worn and insulated adjustment tools must be used when working with
a drive under power. This product is constructed of materials (plastics, metals, carbon,
silicon, etc.) which may be a potential hazard. Proper shielding, grounding, and filtering
of this product can reduce the emission of radio frequency interference (RFI) which may
adversely affect sensitive electronic equipment. It is the responsibility of the equipment
manufacturer and individual installer to supply this Safety Warning to the ultimate end user
of this product. (SW 8/2012)
The control does not provide motor over temperature protection. The user is responsible
for providing this protection in the equipment where this control is used (Remarque: La
détection de la surchauffe du moteur n’est pas assurée par cette control).