TABLE 1.2 1586-0400431 Status Requests
Command Syntax *Description
Get Channel 1 Gain {aaSA} returns {aaSAyyy.y}
where:
aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit
A = command code (case sensitive, capital A)
yyy.y = Channel gain in dB.
The unit will reply with the '>' character if the command is sucessfully processed.
Get Channel 1 Offset {aaSa} returns {aaSayy}
where:
aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit
a = command code (case sensitive, lower case a)
yy = Channel offset in dB.
The unit will reply with the '>' character if the command is sucessfully processed.
Get Channel 2 Gain {aaSB} returns {aaSByyy.y}
where:
aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit
B = command code (case sensitive, capital B)
yyy.y = Channel gain in dB.
The unit will reply with the '>' character if the command is sucessfully processed.
Get Channel 2 Offset {aaSb} returns {aaSbyy}
where:
aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit
b = command code (case sensitive, lower case b)
yy = Channel offset in dB.
The unit will reply with the '>' character if the command is sucessfully processed.
Get Channel 3 Gain {aaSC} returns {aaSCyyy.y}
where:
aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit
C = command code (case sensitive, capital C)
yyy.y = Channel gain in dB.
The unit will reply with the '>' character if the command is sucessfully processed.