CryptOn 660-R Manuale utente

OPERATING INSTRUCTIONS
TES1489/A
Dec 2005
BRAKE TESTER 660-R

660-R OPERATING INSTRUCTIONS Page 2
IMPORTANT
Every reasonable effort has been made to ensure that information within
these Operating Instructions is correct at the time of release, but Crypton
cannot accept-responsibility for any errors that may occur.
The information in these Operating Instructions is subject to change
without notice, and does not represent a commitment on the part of
Crypton.
Service & Warranty
The reliability of this equipment is fully supported by our service agent.
Please refer to the page at the end of this manual for full details.
Note:
Your attention is drawn to our Terms & Conditions of Sale. If a service
engineer is called out. under service warranty where, upon inspection and
test the equipment is found to be in full working order and no fault found,
the user is liable to be charged the cost incurred for this call out. Before
calling out an engineer, ensure your equipment is faulty by checking its
operation, particularly mains supply and fault codes/self test if applicable.
WARNING:
Do not attempt to operate this equipment unless you have read
and understood these
instructions.

660-R OPERATING INSTRUCTIONS Page 3
CONTENTS
Safety precautions 4
Hints and Tips 5
INTRODUCTION 6
Description of system components 6
Emergency switch 6
Pit unit 6
Control unit 8
Motor control 8
Alternative display 8
Printer 8
Remote control 9
Guide to testing 11
Test description 12
MOT Test Procedure – Class IV 12
Enter car on PC 12
Reset system 12
Front Axle 12
Centre 12
Left brake test 12
Right brake test 12
Bind, ovality and imbalance test 12
Rear Axle 13
Centre 13
Left brake test 13
Right brake test 13
Bind, ovality and imbalance test 13
Parking Brake 14
Left brake test 14
Right brake test 14
Printing results 14
Manual Testing 15
Class IV 15
Class III - Testing one wheel only 16
Prompt sheet 17
Calculations 18
Maintenance 19
Technical Specification 21
After Sales Service 22
Notes 23

660-R OPERATING INSTRUCTIONS Page 4
SAFETY PRECAUTIONS
Read these operating instructions carefully and thoroughly before
attempting to operate the equipment.
This operating manual should be available at the testing site at all times.
Always follow the procedures and actions defined in this manual, failure to
do so may result in personal injury or other damage. The manufacturer
cannot be held liable for personal injuries or vehicle damage that occur as
a result of misuse of the equipment.
All the national and international safety guidelines and legal regulations
are to be followed when operating testing equipment.
The operator is obliged to adhere to all the regulations applying to the
workplace and to ensure his knowledge of such regulations is up to date.
Do not allow other personnel near the test vehicle or rollers while a test is
in progress. Check that the area is clear before the rollers are started or
the vehicle moved EACH TIME this action is taken.
Testing often takes place with the engine running, to provide a vacuum
supply to the brake servo. Ensure exhaust extraction or adequate
ventilation is used to clear the poisonous exhaust gasses.
Do not modify the equipment or change any internal settings – this could
result in a very dangerous condition where the rollers could be started
WITHOUT a vehicle in the rollers!
TESTING STANDARD
When performing statutory MOT tests it is vital to follow the brake
test procedure detailed in the latest version of the relevant MOT
Inspection Manual

660-R OPERATING INSTRUCTIONS Page 5
HINTS & TIPS
The brake tester must only be used for its intended purpose.
All the performance limits are to be followed, do not drive excessively
heavy vehicles over the pit unit or otherwise abuse the equipment as
damage may occur and test result accuracy may be affected.
Only authorised and well-trained personnel should perform the testing.
The work area should be kept clean and dry.
Always keep a safe distance from moving parts. The area must be marked
so that vehicle owners are aware of the danger associated with brake
testing.
Note the location of the emergency stop switch before starting to use the
equipment.
When driving off the brake tester, the roller motors should be switched on
so that the rollers are driven. This limits the speed of the rollers to a safe
value. If the vehicle is driven off the rollers without them being powered
damage may occur.
Do NOT use the brake tester to start the engine of a vehicle as this may
damage the electric motors.
Drive on and off the tester slowly and in a controlled manner.
Always check the ground clearance of the vehicle is adequate before
performing the test.

660-R OPERATING INSTRUCTIONS Page 6
INTRODUCTION
The 660-R is a roller brake tester designed to perform VOSA MOT tests on
Class III and Class IV vehicles.
Control can be performed using the remote handset at the vehicle so one
man operation is possible and a printer is available to produce a record of
results if fitted.
Description of system components
The roller brake tester consists essentially two parts: one above ground,
the control and display console and one below ground, the road simulation
rollers. A brief description of the various features follows:
Emergency switch
The brake tester is equipped with an emergency stop switch. Note the
location of the emergency stop before starting to use the equipment. The
emergency switch is not necessary positioned in the same place at every
installation, check the location before using the equipment.
Pit unit
The rolling road consists of two sets of free roller pairs connected by a
chain and indirectly driven by two electric motors through gearboxes. The
gearbox is joined to the roller tester frame by a force transducer. During
the motor operation when the car is braking, the resultant force is
transmitted from the rollers to the brake force transducer. The outputs of
the transducers are monitored by the internal circuits and eventually
shown on the display as brake effort.
A small third roller is fitted between each pair of main rollers. These
perform two vital functions. Firstly to monitor the presence of a wheel in
the rollers so that motors can only be energised when a vehicle is present
and secondly to measure speed of the wheel that is being braked. This
ensures that the motors are automatically switched off when the tyre
starts to slip on the roller surface.

660-R OPERATING INSTRUCTIONS Page 7
660-R MOT Class III and IV Roller Brake Tester

660-R OPERATING INSTRUCTIONS Page 8
Control unit
The control unit contains front panel with:
Green indicator light : Car on rollers / Rollers drive direction / 4WD
(Arrows Lup, LDn, Rup, RDn)
Red indicator lights: Wheel locks (Lock left & Right)
Green indicator light : Ready for test (Ready)
Scale showing brake force:
Pointers: Green for left, red for right
Digital display (DDsp): Imbalance, ovality, pressure, weight
Amber indicator lights: Showing type of information on digital display
(Oval, Pres, Wght)
Inside: Power supply board for control computer, front panel,
amplifiers and motor control
Outside: Main switch, Emergency switch
Alternative display
A twin dial display can be specified when ordering a 660-R and this has
two separate dials mounted side by side rather than the co-axial
arrangement. All scales and other indicators are identical as shown:
Printer
The printer is an optional device that can be specified at the time of
purchase or fitted later. Follow the instructions in the printer handbook
for loading paper and fitting ink cartridges (if applicable).

660-R OPERATING INSTRUCTIONS Page 9
Remote control
Remote control consists of 16 keys, some of which have dual function
which are activated through the 2nd key.
START: Used to start the rollers
when the system is ready
for a test or restart during
a test.
STOP: Used to stop the rollers,
any roller that is running
will stop. To stop the test
completely, press OK
while the DDsp = STP
UP ARROW: Used for axle selection.
DOWN ARROW: Used for axle selection
OK: Press to save results
from the last test step.
LEFT ARROW: Used for wheel selection
RIGHT ARROW: Used for wheel selection
DIFF: Selects imbalance when
both wheels are running.
4WD: Used to switch test procedure into a special mode that rotates
wheels in opposite directions during all test steps so that prop
shaft does not rotate.
SEC: Used to initiate secondary brake test
PARK: Used to initiate parking brake test
OVAL: Used to initiate ovality measurement
WGHT: Used for weight input
AXLE: Used for axle selection

660-R OPERATING INSTRUCTIONS Page 10
PRINT: Used to print test results
TEST: Starts both rollers so that vehicle can be driven out
2 nd: This key activates the second function of other keys
2 nd STOP: Will RESET the system and clear all previous results
so that a new vehicle test is activated.
When the system is RESET the DDsp shows CL4
2 nd WGHT: Allows manual weight entry. DDsp = At
Respond by pressing AXLE for individual axle weight entry or
TEST for gross vehicle weight. Enter the weight in 100kg units
i.e. 100 = 10 Tonnes. Then press OK
2 nd OK: System internal test, DDsp = TsT
Note: The Fn key is not currently used on this model.
Indice
Altri manuali CryptOn Apparecchiature di prova
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione