Denkovi smartDEN IP-16R Series Manuale utente

smartDEN IP-16R-XX User Manual
13 Apr 2021
-1-
smartDEN IP-16R-XX
Web-enabled Ethernet-based 16 Relay Modules
User Manual
Date: 13 Apr 2021
Device
Short Name
Integration Protocol
Firmware version
smartDEN IP-16R
SNMPv2
v1.20 / May 2017
smartDEN IP-16R-MT
Modbus TCP
v1.21 / Jul 2020
smartDEN IP-16R-MQ
MQTT V3.1.1
v1.21 / Sep 2020

smartDEN IP-16R-XX User Manual
13 Apr 2021
-2-
Content
1. Features .............................................................................................................3
2. Ordering Codes..................................................................................................4
3. Application examples........................................................................................5
4. Technical parameters.........................................................................................7
5. Connectors, ports and led indicators.................................................................8
6. Installation.........................................................................................................9
7. Default Settings...............................................................................................16
8. Web access......................................................................................................18
9. HTTP/XML/JSON access...............................................................................36
10. Integration Protocols .....................................................................................41
11. Security considerations .................................................................................64
12. Appendix 1. Mechanical dimensions............................................................65
13. Appendix 2. Application reply formats.........................................................66

smartDEN IP-16R-XX User Manual
13 Apr 2021
-3-
1. Features
smartDEN IP-16R-XX is a LAN relay module with 16 SPDT relays for remote
control with integrated web server for set-up, API integration protocol (depending on
the model) and http/xml/json support for embedding in other systems. The built-in
real time clock allows organizing schedule stand-alone work without connection to
computer. The module is able to act like network watch-dog in order to monitor and
reboot network equipment automatically.
10 Mb Ethernet interface with Link/Activity Led;
Auto-MDIX;
16 SPDT relays (with NO and NC contacts);
Led for each relay;
Pulse function (timer) for every relay;
Real Time Clock (RTC) for schedule (calendar) stand-alone work;
Web server with secure login authorization;
Secure HTTP/XML/JSON API protocol support for read/write relays status;
Integration protocol:
oSNMPv2 - for smartDEN IP-16R;
oModBUS TCP - for smartDEN IP-16R-MT;
oMQTT V3.1.1 - for smartDEN IP-16R-MQ;
Supported by various Home Automation systems like Domoticz, OpenHab,
Home Assistant, Node-Red;
Supported protocols: ARP, IP, ICMP (ping), DHCP, DNS;
Watch-Dog Auto-Reboot ICMP (outgoing) function;
Access protection (by IP and MAC address);
Option for relays states saving and loading on reset;

smartDEN IP-16R-XX User Manual
13 Apr 2021
-4-
2. Ordering codes Table 2.1. Ordering codes
Short Name
Ordering Codes
Description
smartDEN IP-16R
smartDEN IP-16R-12V-PCB
SNMP model, PCB version,
12VDC supply voltage
smartDEN IP-16R-24V-PCB
SNMP model, PCB version,
24VDC supply voltage
smartDEN IP-16R-12V-BOX
SNMP model, BOX version,
12VDC supply voltage
smartDEN IP-16R-24V-BOX
SNMP model, BOX version,
24VDC supply voltage
smartDEN IP-16R-MT
smartDEN IP-16R-MT-12V-PCB
Modbus TCP model, PCB
version, 12VDC supply
voltage
smartDEN IP-16R-MT-24V-PCB
Modbus TCP model, PCB
version, 24VDC supply
voltage
smartDEN IP-16R-MT-12V-BOX
Modbus TCP model, BOX
version, 12VDC supply
voltage
smartDEN IP-16R-MT-24V-BOX
Modbus TCP model, BOX
version, 24VDC supply
voltage
smartDEN IP-16R-MQ
smartDEN IP-16R-MQ-12V-PCB
MQTT model, PCB version,
12VDC supply voltage
smartDEN IP-16R-MQ-24V-PCB
MQTT model, PCB version,
24VDC supply voltage
smartDEN IP-16R-MQ-12V-BOX
MQTT model, BOX version,
12VDC supply voltage
smartDEN IP-16R-MQ-24V-BOX
MQTT model, BOX version,
24VDC supply voltage

smartDEN IP-16R-XX User Manual
13 Apr 2021
-5-
3. Application examples
Remote control of electrical appliances
Industrial automation
Home automation
Watchdog monitoring of network equipment and auto-reboot
Internet of Things (IoT)
Figure 3.1. smartDEN IP-16R-XX supports up to 30 schedule events for
controlling appliances without connection with computer.
Figure 3.2. Cloud access smartDEN IP-16R-MQ via MQTT Broker for IoT, Home
Automation and Industrial Automation applications.

smartDEN IP-16R-XX User Manual
13 Apr 2021
-6-
Figure 3.3. Easily access smartDEN IP-16R-XX via internet or LAN and control
appliances remotely for Home Automation and Industrial Automation applications
using some of the supported integration protocols.
Figure 3.4. smartDEN IP-16R-XX supports periodically sending outgoing ping
request to remote host (router, switch, PC, IP camera...) and upon timeout it will
perform reboot of the device in order "to keep it alive".

smartDEN IP-16R-XX User Manual
13 Apr 2021
-7-
4. Technical parameters Table 4.1. Technical parameters
Parameter
Value
Box size, mm
210 x 85 x 58
PCB size, mm
203 x 82
Box weight, g
420
PCB weight, g
285
Power supply voltage,VDC
12 or 24 (depends on the model) ±2
Maximum current consumption at
12VDC (when all relays are ON), mA
600
Maximum current consumption at
24VDC (when all relays are ON), mA
400
Operating temperature, °C
0 to 70
Relays maximum switchable current /
voltage
10A / 250VAC, 15A / 120VAC, 10A /
28VDC

smartDEN IP-16R-XX User Manual
13 Apr 2021
-8-
5. Connectors, ports and led indicators
Bellow is shown a picture with the device connectors, ports and led indicators.
Figure 5.1. Device overview

smartDEN IP-16R-XX User Manual
13 Apr 2021
-9-
6. Installation
This device must be installed by qualified personnel;
This device must not be installed directly outdoors;
Installation consists of mounting the device, connecting to an IP network,
connecting the relays, providing power and configuring via a web browser.
6.1. Box mounting
Figure 6.1. Mounting the device to DIN rail
smartDEN IP-16R-XX can be mounted to a standard (35mm by 7.55mm) DIN rail.
Attach the module to the DIN rail by hooking the hook on the back of the enclosure to
the DIN rail and then snap the bottom hook into place.

smartDEN IP-16R-XX User Manual
13 Apr 2021
-10-
6.2. Power supply
Figure 6.2. smartDEN IP-16R-XX power supply
Depending on the selected model during purchase the power supply source for
smartDEN IP-16R-XX must be with voltage either 12VDC or 24VDC stabilized and
filtered. After power on, the power led must be on and Led1 indicator must start
blinking in 5 seconds which means the controller is running normally.
Figure 6.3. Connecting a LAN cable
Please keep the polarity and supply voltage range!
smartDEN IP-16R-XX does not accept AC supply voltage. It is highly
recommended to check the power supply source parameters before supply
the module.
The power supply equipment shall be resistant to short circuit and
overload in secondary circuit.
When in use, do not place the equipment so that it is difficult to disconnect
the device from the power supply.
Questo manuale è adatto per i seguenti modelli
14
Indice
Altri manuali Denkovi Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente