NOTICE: A qualied electrician must connect electrical wiring to duplex outlet for built-in
installation. Follow all local codes.
Figure 1 - Installing Duplex Outlet
Cable from
Electrical
Source
Duplex Outlet
Screw
Blower
Power
Cord
Blower
Support Bracket
GA3555 OUTLET KIT InsTALLATIOn InsTRUCTIOns
IMPORTANT: Read entire instruction sheet before
installing GA3555 Outlet.
This outlet kit contains the following:
Qty. Part No. Description
1 103706-01 4" x 5 1/4" Silver Shield
2 098304-03 Black Screws, #8 x 3/8"
1 M12461-2 Zinc Screw, #6-32 x 3/8"
1 ** Duplex Receptacle
1 103771-01 Strain Relief Fitting
**Not sold separately
If any of these parts are missing or damaged,
contact dealer where you purchased this kit. If
they cannot supply original replacement parts, call
DESA Heating Products at 1-866-672-6040 for
referral information.
1. Install blower assembly per instruction sheet
included.
2. Beforereplacingbottomofrebox,install
duplex outlet to the right support bracket in the
bottomofrebox(seeFigure1).
3. Route wires from electrical box through small-
estholeinoutercasingusingstrainrelieftting
provided(seeFigure1).
4. Connect wires from the electrical box to duplex
outlet. Match wire colors to those indicated on
duplex outlet. Be sure to connect ground wire.
5. Install shield to end of right support bracket
andbehindthereboxwrapperwith2screws
provided(seeFigure2).
6. Plug blower power cord into duplex outlet.
Note: Onthermostatmodelreplaces,route
powercordtothebackofthereplacetoclear
thermostatvalve(seeFigure2).
7. Replacebottomofrebox.
Figure 2 - Installing Shield
Shield
Screws
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
www.desatech.com 103707-01
Rev. D
02/06
Support Bracket
Firebox
Wrapper
Power
Cord
Strain Relief
Fitting