digicon catrax automatic master Manuale utente

Product Manual


Copyright– Digicon S.A.
Electronic Control for Mechanics – 2014
All rights reserved. No part of this publication may be reproduced, transmitted,
transcribed, stored in a retrieval system, translated into any language or computer
language in any electronic, magnetic, optical, chemical, manual way, or otherwise,
without the express written permission from Digicon S.A.
Manual code: 069.31.202
English - Revision: 02
This manual was elaborated by: Digicon S.A. Controle Eletrônico para Mecânica
Documentation Sector - EDS

1. mportant InstructionsI ...................................................
2. Orientations ..................................................................
3. Introduction ..................................................................
4. Features of Automatic Master ..........................................
4.1 Automatic Master Operation ...........................................
5. Installing/Assembling .....................................................
5.1 Unboxing ....................................................................
5.2 Floor drilling and column fixation ...................................
5.3 Assembling the arms ...................................................
5.4 Access to Automatic Master after assembly ......................
5.5 Connection to power network ........................................
6.Installing/Assembling operational items .............................
6.1 Rear closure kit ...........................................................
6.2 Collecting box kit .........................................................
6.2.1 Connection of collecting box kit to control board ............
6.3 Operational pictogram kit ..............................................
6.4 Orientation pictogram kit ..............................................
6.5 Power Supply ..............................................................
6.6 Electromechanical counter kit ........................................
6.7 Control Board ..............................................................
6.7.1 Inputs .....................................................................
6.7.1.1 Return signals ........................................................
6.7.1.2 Electromagnets ......................................................
6.7.1.3 Sound alarm ..........................................................
6.7.1.4 Connetcion scheme ................................................
6.7.1.5 Pictogram .............................................................
6.7.2 Output ....................................................................
6.7.3 Control board configuration ........................................
6.7.4 Turnstile interface .....................................................
6.8 Anti-Panic system ........................................................
6.8.1 Maintenance test .......................................................
7. Maintenance .................................................................
7.1 Preventive and corrective rountine maintenance ..............
7.2 Solving problems .........................................................
8. Technical characteristcs ..................................................
9. Warranty and technical assistance ....................................
Contents
05
06
06
07
08
09
09
10
11
12
14
15
15
16
16
17
17
18
18
19
21
22
22
23
23
24
24
24
26
32
33
34
34
35
36
38

05
1. mportant nstructionsI i
You can see, below, the symbols that will appear in this manual,
signaling important moments. It is essential to pay attention to them.
TIP: Indicates something Digicon considers important.
CAUTION: Indicates a moment of extreme caution when
handling the equipment/product
ATTENTION: Indicates a moment when your observation
skills should be extremely productive.
INFORMATION: Presents interesting facts about the
purchased product.
QR CODE: Presents additional information or links
with more details about the presented text.

Following a new technological concept focused on solidity and reliability and counting
with innovative design elements, with color variety and widely curved lines, Digicon has
launched the line Automatic Master.
Automatic Master serves most technologies of access control currently available,
becoming the best option in the market for access control.
This manual presents a detailed description of the components and working of
Automatic Master. To see our complete catalogue, visit www.digicon.com.br.
06
2. Orientations
Read the information and instructions of this manual carefully, before using the
product. This ensures the correct use of the equipment and maximum use of its
technical features as well as a prolonged service life.
This product does not present sealing against the rain, that is, it is designed to be
used indoors.
Keep this manual for future consultations.
Digicon reserves its right to alter its products at any moment to adapt them to more
recent technical advancements.
Digicon maintains its right to alter the information contained in this manual without
previous notice.
Digicon does not provide any contractual warranty concerning the information in this
manual, and cannot be held responsible for errors it may contain and problems due
to its use.
The information contained in this manual is exclusive property of Digicon and is
protected by copyright laws.
This manual cannot be reproduced, photocopied or translated, in its entirety or in
part, into any kind of medium, without Digicon's written consent.
3. Introduction

The structure of Automatic Master can present external finishing in brushed stainless
steel (AISI 304) or 1020 carbon steel with electrostatic painting in black epoxy powder.
It has reinforced structure, fully rounded corners, and non-exposed screws, offering
space and comfort for any access control solution. Aiming at facilitating assembly and
maintenance, the column Automatic Master presents a U-shaped internal support
(mounting rack) with standard holes for the fixation of additional electronic boards.
Moreover, the clients, according to their needs, can add additional holes. Access to the
mounting rack is done through a key with secret, whose removal and insertion are
extremely easy.
A plastic cover and a stainless steel sheet compose the upper panel. The cover, made of
injected plastic, can be purchased in the colors green, burgundy, or black or in any
other color desired, on demand.
The upper cover in stainless steel allows easy configuration and low-cost customization
of the product. The sheet can also present slots for optional items, such as operational
pictogram (on top), orientation pictogram (side), collecting box inlet, display kit or a
combination of these items.
07
4. Features of Automatic Master
Automatic Master, an access controller in the model blockage, presents three
bidirectional, equidistant arms at 120 degrees with brushed stainless steel (AISI
304) finishing.

Besides compatibility with most available technologies, Digicon can provide the
following optional items: collecting kit with box, pictogram kit, counter kit, power
supply, power supply, control board, and display kit. These items are described in
details in item 6. Installing/Assembling optional items.
TIP: To see details about the dimensions of Automatic Master's items,
see item 8. Technical characteristics.
4.1 Automatic Master operation
A Automatic Master has bidirectional motorized turning with two 24 Vcc
electromagnets for activating the locks. It also includes a microprocessor control
board, where a signal enabling passage is sent through one of the inputs, depending on
the passage direction. If this signal is recognized, the equipment will allow the turning
of the arm of Automatic Master. After half of the turning is complete (60 degrees), a 400
milliseconds returning signal will be sent, informing the passage direction. After the
signal, the arm cannot be returned to the previous position.
Depending on the Automatic Master model and configuration, if the passage is forced
without the enabling signal, an electromagnet will be activated to prevent turn. In
addition, the equipment can emit a signal for a sound alarm and/or the exhibition of a
red X on the upper panel display (models with pictogram). In this case, a return signal
will be sent, indicating that the turnstile was forced, informing the direction of turn.
The image below shows the operation mechanism of Automatic Master.
08
SENSORS
LOCKS
SOLENOID
ARM

5. Installing/Assembling
5.1 Unboxing
As the items inside the package can vary (depending on the client's requests), it is
important to perform a cautious visual inspection before installing and assembling the
turnstile. A checklist that works as a guide during inspection accompanies all Digicon
packages. See below the parts that can compose Automatic Master:
OPERATIONAL PICTOGRAM
(OPTIONAL)
LOCK FORACCESSING
THE COLUMN
ORIENTACION PICTOGRAM
(OPTIONAL)
COLUMN
ARM
CENTRAL COVER
EXTERNAL COVER
LOCK FOR RACK AND COLUMN
DIGITAL COUNTER
(OPTIONAL)
COLUMN DOOR
09

5
209
30
80
35
941
1001
12,5 (4X)
5.2 Floor drilling and column fixation
Before installing Automatic Master, check:
1. if the floor has conditions to receive anchor bolts (at least 4cm of FCK15 M.P.A.
concrete or equivalent)
2. If there is a power source or electric socket nearby (ducts for connection).
3. If the place chosen is adequate for the installation of the access controller (indoors).
4. If access to the Automatic Master's locks is clear.
5. If there will be enough space for the arms after Automatic Master is assembled.
ATTENTION: For more details on the dimensions of Automatic Master's
components, see item 8. Technical characteristics.
Once you observe these recommendations, proceed to the installation:
1. rill the floor with 3/8” drills (then use a 12mm or the ½” drill). Make two holes inD
each column of Automatic Master, according to the measures indicated in the image
below:
2. Clean the holes, removing any debris from drilling.
3. Place the external part of the bolts in the holes. Leave about 25mm of the bolt out of
the hole.
TIP: We reccomend anchor bolts by Tecnart, model AF38110, 3/8x4”.
4. Position the column and fasten it to the floor with the four screws that accompany the
bolts. Use a flex-head socket wrench with ¾'' or an articulated socket wrench.
10
Indice
Altri manuali digicon Controllori di accesso IP