digicon dTower Manuale utente

Product Manual
Tower


All rights reserved. No part of this publication may be reproduced,
transmitted, transcribed, stored in a retrieval system, translated into any language
or computer language in any electronic, magnetic, optical, chemical, manual way,
or otherwise, without the express written permission from Digicon S.A.
Code: 069.31.221
Version: 0 -2 English
This manual was elaborated by: Digicon S.A. Controle Eletrônico para Mecânica
Documentation Sector - EDS
Copyright– Digicon S.A.
Controle Eletrônico para Mecânica – 2017
©
Tower

Contents
05
06
06
07
08
09
09
10
14
15
16
17
22
24
24
25
26
26
26
27
1. .................................................................................Important instructions
2. ...............................................................................................Orientations
3. ...............................................................................................Introduction
4. ......................................................................................Features of dTower
4.1 ....................................................................................dTower Pictograms
5. ............................................................................Installing and Assembling
5.1 .................................................................................................Unboxing
5.2 .......................................................................Fixing dTower to the ground
5.3 .................................................................Accessing dTower after assembly
5.4 ..........................................................Connections among equipment pieces
5.5 .......................................................Connection to power and data networks
5.6 ..........................................................................Connecting control signals
5.7 controller board .................................................................Configuration of
6. ...............................................................................Technical characteristics
6.1 ..............................................................................................Dimensions
6.2 ......................................................................................Other information
7. ....................................................................................................Cleaning
7.1 ........................................................Maintenance and preservation of doors
7.2 ....Maintenance and preservation of dTower (glasses and stainless steel sheets)
8. .................................................................Warranty and technical assistance
Tower

1. Important instructions
You can see, below, the symbols that will appear in this manual, signaling
important moments. It is essential to pay attention to them.
TIP: Indicates something Digicon considers important.
CAUTION: Indicates a moment of extreme caution when
handling the equipment/product.
ATTENTION: Indicates a moment when your observation
skills should be extremely productive.
INFORMATION: Presents interesting facts about the
purchased product.
QR CODE: Presents additional information or links with
more details about the presented text.
05
Tower

06
Read the information and instructions of this manual carefully, before using the
product. This ensures the correct use of the equipment and maximum use of its
technical features as well as a prolonged service life.
This product does not present sealing against the rain, that is, it is designed to
be used indoors.
Keep this manual for future consultations.
Digicon reserves its right to alter its products at any moment to adapt them to
more recent technical advancements.
Digicon maintains its right to alter the information contained in this manual
without previous notice.
Digicon does not provide any contractual warranty concerning the information
in this manual, and cannot be held responsible for errors it may contain and
problems due to its use.
The information contained in this manual is exclusive property of Digicon and is
protected by copyright laws.
This manual cannot be reproduced, photocopied or translated, in its entirety or
in part, into any kind of medium, without Digicon's written consent.
The equipment described here is customizable, that is, this manual describes
all possible models and they may not reflect, necessarily, the model purchased
by the customer.
2. Orientations
3. Introduction
Gate line especially developed for access control solutions that operate in small
spaces. Using the comfort and safety of swing gate doors, the dTower line offers
maximum flexibility with minimum use of space.
Tower

4. Features of dTower
-Innovative design, according to the dGate and dFlow lines;
-Robust solution, with motorized system and control with proprietary technology;
-Reinforced structure for fixing it to the ground;
-Available in stainless steel and carbon steel painted in powdered epoxy;
-Available with doors in 1 mm polymer – more resistant to impacts;2
-Very fast door opening;
-Offers operational pictogram (top) – clear access;
-Offers orientation pictograms (front) for both directions;
-Offers sound signal (beep) to indicate access cleared or denied;
-Doors with bidirectional movement;
-Inputs for activation sensors that open or close the doors;
-Optional card collecting box;
-Allows installation of reader on the edges;
-Easy integration with access controllers available in the market.
07
Tower

4.1 dTower Pictograms
dTower has two pictograms: direction and operation
A) Operational pictogram (top):
The operational pictogram is installed on the upper part of the equipment and is
represented by a sequence of LED lights in several colors, depending on the
operational flow direction and validation group, if it exists.
LED lights flashing red or flowing in the opposite direction represent passage not
cleared.
LED lights flashing green indicating the direction of passage represent cleared
passage.
B) Orientation Pictogram (front)
The orientation pictogram is installed on the edges of the equipment and is
represented by a green arrow > or red x.
The red pictogram informs the user that dTower is not operating in the indicated
direction or that passage is not allowed, or even that it is busy.
The green pictogram informs the user that dTower is free or controlled for passage
in the indicated direction.
08
Tower
and

5. Installing and Assembling
5.1 Umboxing
As the items inside the package can vary (since the equipment is customizable), it is
important to perform a cautious visual inspection before installing and assembling the
turnstile. A checklist that works as a guide during inspection accompanies all Digicon
packages. In case of missing pieces, immediately contact the Digicon representative
responsible for the sale.
2D Reader
Orientation
pictogram:
and
Operational
pictogram
Swing Gate
Door
Upper
cover
Key Lock
Access Door
Stainless Steel Column
Identification
label (by color)
09
Tower

5.2 Fixing dTower to the ground
The image below indicates the points for fixing the product to the ground.
The surface must be steady and leveled to ensure good performance for the
passage-controlling sensor and to maintain the doors aligned.
Fixing can be done through mechanical bolts, also known as parabolts, or through
chemical anchorage.
It is very important to check, upon installation, the alignment of the doors in the
closed position. The distance, from top to bottom, must be the same.
TIP:
To fasten the bolts, use a tool with long extensor.
- Fixing points
- Optional fixing points
INFORMATION: Measures are given in millimeters and (inches).
10
Tower
170(6,692")
93
(3,661")
90(3,543")
80
(3,14")
24(0,944")
Ø15(0,590")
Ø13(0,511")
TIP: We recommend bolts by Tecnart, model AF38110, 3/8x4''.