DGT4
Digital weight transmitter with 4 channels
ENGLISHUSER MANUAL
For DGT4 with firmware release minimum 08.03


3
Optimized layout for A4 print.
TECH_MAN_ENG_DGT4_V8
Contents
Introduction 7
Transmitter installation 8
Installation requirements 8
Electrical precautions 9
Earthing of the system 11
Technical features 14
Load cell installation 15
Wiring diagrams 16
DGT4 16
DGT4AN 17
DGT4PB 18
DGT4ETHIP, DGT4ETHCAT, DGT4PRONET, DGT4MODTCP 19
DGT4CANOP 20
DGT4DEVNET 21
Display and function of the keys 22
Quick menu 22
Advanced programming menu 23
Access to the menu and saving the changes 23
Function of the keys in the menu 23
Block diagram of the menu 24
Mode of use of the DGT4 26
On / Off 27
Theoretical calibration 28
Dependent channels 28
Independent channels / transm 29
Calibration with sample weights 30
Dependent channels (with digital equalisation) 30
Independent channels / transm 32
Equalisation 34

4
Optimized layout for A4 print.
TECH_MAN_ENG_DGT4_V8
Manual calibration 35
Manual calibration 35
Quick zero calibration (pre-tare zeroing) 35
Filter and stability 36
Filter adjustment 36
Stability detection sensitivity 36
Display updating frequency 37
Gravity 37
Zeroing parameters 38
Auto-zeroing on ignition 38
Maximum percentage of manual zeroing 38
Zero tracking 38
Restoring zero 39
Semi-automatic zeroing 39
Tare functions and parameters 40
Tare mode 40
Semi-automatic tare 40
Predetermined tare 40
Clearing the tare 40
Alibi memory 41
Enabling the alibi memory 41
Saving a weighing operation in the alibi memory 41
Reading the alibi memory 42
Initialising the alibi memory 42
Use functions 43
High resolution 43
Peak detection 43
Converting units of measurement 43
Alibi memory 43
No function 43
Input configuration 44
Output configuration 45

5
Optimized layout for A4 print.
TECH_MAN_ENG_DGT4_V8
Analog output configuration 46
Serial communication configuration 48
Selection of the PC serial port 48
Configuration of the printer port (COM.PRN) 49
Transmission mode 49
Baud rate, parity, data bits, stop bits 50
Printer power on mode 50
CTS signal 50
Print language 50
Reactivation of printing 51
Configuration of the PC port (COM.PC) 51
Transmission mode 51
Baud rate, parity, data bits, stop bits 52
Communication protocols 53
Standard string 53
Extended string 53
Multi-scale string 54
Serial commands 55
Diagnostics 58
Cells / converter test 58
Firmware release 58
Serial number 58
Display 58
Keypad 58
Serial ports 59
CTS signal 59
Inputs 59
Outputs 59
Analog output (mod. DGT4XAN) 59
Programming the Setpoints 59
Restoring factory settings 60
Date and time setting 60
Alarms 61

7
Optimized layout for A4 print.
TECH_MAN_ENG_DGT4_V8
Dear Customer,
Thank you for purchasing a DINI ARGEO product.
This manual contains all the instructions for a correct installation and commissioning of the DGT4 4-channel digital weight transmitter.
While thanking you for purchasing this product, we would like to draw your attention to some aspects of this manual.
This booklet provides useful information for the correct operation and maintenance of the scale to which it refers; it is therefore essential
to pay the greatest attention to all those paragraphs that illustrate the simplest and safest way to operate.
It is recommended that you carefully follow the instructions for programming the weight transmitter; performing actions not indicated in
this manual could compromise the proper functioning of the scale.
The utmost care has been taken in compiling this manual, but reports of any inaccuracies are always welcome.
The instrument is covered by warranty and MUST NOT BE TAMPERED WITH BY THE USER under any circumstances.
Any attempt at repair or modification may expose the user to the danger of electric shock and voids any warranty conditions, relieving
the Manufacturer from all liability.
Any problem with the product must be reported to the manufacturer or to the retailer where it was purchased.
In any case, always TURN OFF THE POWER SUPPLY before any installation or repair operation.
Introduction

8
Optimized layout for A4 print.
TECH_MAN_ENG_DGT4_V8
Transmitter installation
Installation requirements
Observe the following conditions for correct installation of the transmitter and of the load receiver:
• Flat, level support surface.
• Stability and absence of vibrations.
• Absence of aggressive dusts and vapours.
• Absence of draughts.
• Make sure that the platform is levelled or that the load cells are evenly supported.
• Moderate temperature and humidity (15°C - 30°C and 40% - 70%).
• Do not install in an environment where there is a risk of explosion.
• All transmitter connections must be made in accordance with applicable regulations in the area and environment of installation.
Observe the electrical precautions listed in the section “Electrical precautions”.
• Ensure that it is correctly earthed, see the relevant section “Earthing of the system”.
• Do not perform welding when the load cells have already been installed.
• If necessary, use watertight sheaths and fittings to protect the load cell cables.
• Any junction boxes must be watertight.
• Anything not expressly described in this manual constitutes improper use of the equipment.

9
Optimized layout for A4 print.
TECH_MAN_ENG_DGT4_V8
Electrical precautions
• Use a regulated mains supply within ± 10% of the rated voltage.
• The electrical protections (fuses, etc.) are the responsibility of the installer.
• Observe the recommended minimum distances between cables of dierent categories (see table on page 10).
• The following cables must comply with the maximum permissible lengths (see table on page 10), they must be shielded and must
beinserted alone in metal conduits or pipes:
- the load cell extension cables;
- the signal amplifier cables;
- the cables for connecting the serial ports;
- the analog output cables.
• The cell or amplifier cables must have an independent input in the electrical panel. They must be connected (if possible) directly to
the terminal block of the transmitter without passing through the conduit with other cables.
• Fit “RC” filters:
- on the contactor coils;
- on the solenoid valve coils;
- on all devices that produce electrical interference.
• If condensation can occur inside the weight transmitter, it is advisable to keep the equipment powered at all times.
• Connections to load cells and any external device must be as short as possible.
• The cable ends (connectors, leads, terminals, etc.) must be installed correctly; the cable shielding must be kept intact until close to
the connection point.
• If the transmitter is placed inside an electrical panel, a shielded cable must also be used for the power supply.

10
Optimized layout for A4 print.
TECH_MAN_ENG_DGT4_V8
Category I Category II Category III Category IV
Distance
≥ 100 mm
≥ 200 mm
≥ 500 mm
≥ 100 mm
≥ 500 mm
≥ 500 mm
Classification
Fieldbus, LAN network
(PROFIBUS, Ethernet,
Devicenet...).
Shielded data cables
(RS232...).
Shielded cables for
analog digital signals
< 25 V (sensors, load
cells...).
Low voltage power sup-
ply cables (< 60 V).
Coaxial cables.
DC supply cables with
voltage > 60 V and <
400 V.
AC supply cables with
voltage > 25 V and <
400 V.
Power supply cables
with voltage > 400 V.
Telephone cables.
Any cable subject to
lightning danger.
Load cell RS232 RS485 Analog output
50 metres with
6 x 0.25 mm2cable;
100 metres with
6 x 0.5 mm2cable.
15 m with baud rate up
to19200.
1200 m with shielded 2 x
24 AWG twisted pair with
outer braid + aluminium
strip.
CURRENT:
100 metres with 2 x 0.25 mm2cable;
150 metres with 2 x 0.5 mm2cable;
300 metres with 2 x 1 mm2cable.
VOLTAGE:
50 metres with 2 x 0.25 mm2cable;
75 metres with 2 x 0.5 mm2cable;
150 metres with 2 x 1 mm2cable.
RECOMMENDED DISTANCES AND CABLE CLASSIFICATION
MAXIMUM ALLOWED LENGTHS
Altri manuali per DGT4
1
Indice
Altri manuali Dini Argeo Trasmettitore

Dini Argeo
Dini Argeo DGT4X Manuale utente

Dini Argeo
Dini Argeo DGT1SP Manuale utente

Dini Argeo
Dini Argeo DGT4XAN Manuale utente

Dini Argeo
Dini Argeo DGT1SX Manuale utente

Dini Argeo
Dini Argeo DGT1P Manuale utente

Dini Argeo
Dini Argeo DGT1S Manuale utente

Dini Argeo
Dini Argeo DGT1S Manuale utente

Dini Argeo
Dini Argeo DGT4X Manuale utente