Index
1 General............................................................................................................................................ 3
1.1 Device Description......................................................................................................................... 3
1.2 Technical Data ............................................................................................................................... 4
1.3 Connection Example...................................................................................................................... 6
1.4 Scale Drawings............................................................................................................................. 10
2 Communication Object Table........................................................................................................ 13
3 Parameters.................................................................................................................................... 15
3.1 General.................................................................................................................................. 15
3.2 Weather alarms..................................................................................................................... 17
3.3 Scene ..................................................................................................................................... 18
3.4 Enable Input a…s ................................................................................................................... 20
3.4.1 a - Switch Sensor ............................................................................................................... 22
3.4.2 a - Switch Dim Sensor........................................................................................................ 25
3.4.3 a - Blind Sensor.................................................................................................................. 26
3.4.4 a - Value/Forced Operation............................................................................................... 29
3.5 Enable Output A…J ................................................................................................................ 32
3.6 Switch .................................................................................................................................... 34
3.6.1 A1 - General....................................................................................................................... 34
3.6.2 A1 - Function ..................................................................................................................... 36
3.6.2.1 A1 - Staircase Function.................................................................................................. 37
3.6.2.2 A1 - External logic.......................................................................................................... 39
3.6.2.3 A1 - Sweep..................................................................................................................... 40
3.6.2.4 A1 - Scene...................................................................................................................... 41
3.7 Blind....................................................................................................................................... 42
3.7.1 A/B –General .................................................................................................................... 42
3.7.2 A/B –Drive Blind................................................................................................................ 44
3.7.3 A/B –Drive Slat.................................................................................................................. 46
3.7.4 A/B –Functions ................................................................................................................. 47
3.7.4.1 A/B –Position/Presets................................................................................................... 48
3.7.4.2 A/B –Weather alarm..................................................................................................... 50
3.7.4.3 A/B –Forced position.................................................................................................... 52
3.7.4.4 A/B –Feedbacks ............................................................................................................ 53
3.7.4.5 A/B –Scene.................................................................................................................... 54

Product Manual RCUXXYY
EAE KNX Room Control Unit RCUXXYY PM R1.0
©EAE Technology www.eaetechnology.com Page 2 / 80
3.8 Valve Control......................................................................................................................... 55
3.8.1 A/B –Control Input............................................................................................................ 55
3.8.2 A –Valve General .............................................................................................................. 57
3.8.3 A –Function....................................................................................................................... 59
3.8.4 A –Limit............................................................................................................................. 61
3.9 Fan Coil.................................................................................................................................. 62
3.9.1 Fan ..................................................................................................................................... 62
3.9.2 A/B1 - Status Message....................................................................................................... 64
3.9.3 A/B1 - Automatic Operation.............................................................................................. 66
3.9.4 A/B1 - Direct Mode............................................................................................................ 67
4 Function Chart............................................................................................................................... 68
5 Object Description......................................................................................................................... 69
5.1 General Object Description ................................................................................................... 69
5.2 Input Object Description ....................................................................................................... 70
5.3 Switch Object Description ..................................................................................................... 72
5.4 Blind Object Description........................................................................................................ 74
5.5 Valve Object Description....................................................................................................... 77
5.6 Fan Object Description.......................................................................................................... 78

Product Manual RCUXXYY
EAE KNX Room Control Unit RCUXXYY PM R1.0
©EAE Technology www.eaetechnology.com Page 3 / 80
1General
1.1 Device Description
•Room Control Unit RCU Series are designed as an all in one product for different room layouts such as
apartments, hotel rooms, hospitals and residences.
•Room Control Unit covers all requirements of the electrical installation of room applications and offers
following functions in one product.
✓Switching lighting
✓Switching loads
✓Controlling AC/DC blinds
✓Controlling fan coils (2 & 3-point valve)
✓Dry contact inputs
•RCUXXYY has XXx16A relay outputs. These outputs are grouped as 5/4/3/2 independent output
channels for XX = 20/16/12/8 respectively. Each channel can be configured to have different
modes of operation as follows,
•Suitable for switching resistive, capacitive and inductive loads as well as fluorescent lamp loads
according to EN 60 669. A single switch output provides following functions,
➢Staircase
➢External logic
➢Internal logic
➢Priority
➢Threshold
➢Operating hour
➢Sweep
•RCUXXYY has YY independent input channels. A single input channel provides following functions,
➢Switch / push button input
➢Dimmer control
➢Control of shutter/blinds
➢Value sending
➢Scene control
➢Counter for count pulse
•Manual control is possible for each channel through the built-in button panel.
•220V auxiliary power is NOT required.
➢Switching output x4
➢AC Blind x2
➢DC Blind x1
➢2 Point valve x2
➢3 point valve x2

Product Manual RCUXXYY
EAE KNX Room Control Unit RCUXXYY PM R1.0
©EAE Technology www.eaetechnology.com Page 4 / 80
1.2 Technical Data RCUXXYY Series
Type of protection
IP 20
EN 60 529
Safety class
II
EN 61 140
Power supply :
- Voltage
21V… 30V DC, SELV
- Current consumption
≤ 10 mA
External supply
-
-
Connections
- Screw terminals
- Max tightening torque
0,5…3,31 mm² solid and stranded wire
0,5…3,31 mm² stranded wire with
ferrule
0.5 Nm
- KNX
Bus connect terminal
Output
- Number
XX output
- Switching voltage
250 V AC; 50/60 Hz
- Switching current 250 V AC
- Switching current 250 V AC,
capacitive loads
16A / AC 1
16A (200µF)
- Maximum switching power
4000 VA
- Mechanical life
> 1 x 106
Type of load
- Incandescent lamp
4000 W
- Halogen lamp
4000 W
- Inductive loads, transformer
2000 W
- Electronic drivers
1500 W
Type of contact
- Potential-free, bistable
Input
- Number
YY binary inputs
- Scanning voltage
5 V pulsed
- Current
1 mA
- Cable length
< 300 m
Installation
- 35mm mounting rail
EN 60 715
Operating elements
- LED (red) and button
For physical address
Temperature range
- Ambient
-5° C + 45° C
- Storage
-25° C + 55° C
Humidity
- max. air humidity
85 % no moisture condensation
Dimensions
Width W in mm
Width W in units (18 mm modules)
66 x W x 90mm
180 mm
10 modules
Weight
0,65 kg
Box
Plastic, polycarbonate, colour grey
CE
In accordance with the EMC
guideline and low voltage
Application program
Communications
objects
Number of addresses(max)
Number of
assignments(max)
254
255
255
Type of protection
IP 20
EN 60 529
Safety class
II
EN 61 140
Power supply :
- Voltage
21V… 30V DC, SELV
- Current consumption
≤ 10 mA
External supply
-
-
Connections
- Screw terminals
- Max tightening torque
0,5…4 mm² solid and stranded wire
0,5…2,5mm² stranded wire with ferrule
0.8 Nm
- KNX
Bus connect terminal

Product Manual RCUXXYY
EAE KNX Room Control Unit RCUXXYY PM R1.0
©EAE Technology www.eaetechnology.com Page 5 / 80
Output
- Number
20 output
- Switching voltage
250 AC; 50/60 Hz
- Switching capacity 250 V AC
16A / AC 1
- Maximum switching power
4000 VA
- Mechanical life
> 1 x 106
Type of contact
- Potential-free, bistable
Input
- Number
18 binary inputs
- Scanning voltage
32 V pulsed
- Current
0.1mA
- Cable length
< 300 m
Installation
- 35mm mounting rail
EN 60 715
Operating elements
- LED (red) and button
For physical address
Temperature range
- Ambient
-5° C + 45° C
- Storage
-25° C + 55° C
Humidity
- max. air humidity
85 % no moisture condensation
Dimensions
Width W in mm
Width W in units (18 mm modules)
66 x W x 90mm
180 mm
10 modules
Weight
0,65 kg
Box
Plastic, polycarbonate, colour grey
CE
In accordance with the EMC
guideline and low voltage
Application program
Communications
objects
Number of addresses(max)
Number of
assignments(max)
254
255
255
NOTE: Device factory default physical address is “15.15.255”.

Product Manual RCUXXYY
EAE KNX Room Control Unit RCUXXYY PM R1.0
©EAE Technology www.eaetechnology.com Page 6 / 80
1.3 Connection Example
RCU2018
Connection Example 1
Connection Example 2

Product Manual RCUXXYY
EAE KNX Room Control Unit RCUXXYY PM R1.0
©EAE Technology www.eaetechnology.com Page 7 / 80
RCU0808
Connection Example 3
Connection Example 4

Product Manual RCUXXYY
EAE KNX Room Control Unit RCUXXYY PM R1.0
©EAE Technology www.eaetechnology.com Page 8 / 80
RCU1212
Connection Diagram 5
Connection Diagram 6

Product Manual RCUXXYY
EAE KNX Room Control Unit RCUXXYY PM R1.0
©EAE Technology www.eaetechnology.com Page 9 / 80
RCU1616
Connection Diagram 7
Connection Diagram 8
Questo manuale è adatto per i seguenti modelli
6
Indice
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente