5.7 OPERATING IN THE -4A MODE
5.7.1 The-4A mode pe fo ms exactly like the DSTS-4A with the EAB-3 option. All
commands a e the same. To ente the -4A mode of ope ation type ‘x’ followed by
the ‘ente ’ key. Once in the -4A mode use the -4A commands. A list of the
commands is attached. In addition typing ‘?’ will b ing up a menu of commands.
5.7.2 Single cha acte commands such as 'A' do not need to be followed by ente .
Multiple cha acte commands such as 'cf' o 'd2345' must be followed by the 'ente '
key.
Command List fo -4A Mode
LETTER FUNCTION
a Sets width Auto T ack mode on. Tu ns off when a width is sent to the DSTS.
A Sets f equency Auto T ack mode on. Tu ns off when a f equency sent to the DSTS.
b Sets no mal (pulsed output) mode of ope ation.
B Sets output signal to continuous wave (CW mode).
C Checks 50 kHz clock f equency.
cf Sets the calib ation to feet.
cF Sets the calib ation to Fathoms.
cm Sets the calib ation to mete s.
cR Extend Depth ange to 9999 FT/FM/MT.
c Reduce Depth ange to 999.9 FT/FM/MT.
dxxxx Sets the bottom depth in tenths of the selected units.
Dxxxx Sets the fish depth in tenth’s of the selected units.
e Tu ns off the fish echo mode. Retu ns one bottom echo.
E Tu ns on the fish echo mode. Retu ns two echoes.
fxxxx Sets the eply f equency in 100 Hz units.
i Retu ns DSTS data on input pulse pa amete s in this o de :
F equency, width, pe iod, P-P voltage.
A typical st ing is 503,192,107,540. Leading 0's a e not sent.
l Sets the eply level in .3 dB steps, 0 to 255 max.
m Retu ns DSTS modes in this o de :
Calib ation 0=ft, 1=fm, 2=mt
Numbe of p ocessed pulses eceived since eset 0-255
Bottom echo o fish with bottom echo bot o fsh
Auto width T ack o manual awt o mwt
Auto f equency T ack o manual aft o mft
CW o pulsed output cwo o pul
Filte settled o not settled. set o nst
A typical st ing is 0,bot,73,awt,aft,pul,set
o Retu ns DSTS data on output pulse pa amete s in this o de :
F equency, width, depth, eply level.
Resets t acking gate and adaptive filte s fo f equency acquisition.
R Resets the DSTS to powe up default mode without exiting RS-232.
v Repo ts the softwa e ve sion.
wxxxxx Sets the bottom echo width in mic oseconds. .
Wxxxxx Sets the fish echo width in mic oseconds.
x Ente s the emote mode of cont ol.
X Exits the emote mode and etu n DSTS to no mal ope ation.
? Sends a simple menu of all commands to the te minal.
DSTS-5A Manual Page 8 Rev 140930-300