Motor control unit IMSG-UC-4H • Status 30/06/2010 • Subject to technical changes. Errors excepted.
4
Storing a movement position
Storing a position is carried out as follows:
•Move the drive to the starting/zero position, i.e. close the window, retract the
awning or raise the blinds
•Press the and buttons for three seconds at the same time
•As feedback the drive moves briefly up and down. You are in now Programming
mode
•Move to the desired position
•Store the position by pressing the and buttons for 1 second long at the same
time
•As feedback the drive moves briefly up and down
•With blind slats, now open the slats to the desired angle. With awnings, tighten the
canvas with . For windows, you can skip this point.
•Store by again pressing the and buttons for 1 second long at the same time
•As feedback the drive moves briefly up and down. The storage is complete and the
IMSG-UC-4H is again in normal mode
Note: As soon as a central command arrives (e.g. because of a wind or rain alarm), the
Programming mode will be interrupted! In this case, please carry out the position storage
again when the central command is no longer present.
Calling up a movement position
The stored position can be called up by pressing the button of the appropriate channel
for 3-6 seconds.
The drive will move to the movement position directly if it is in a secure position and the
runtimes of previous commands have expired. If the drive is in an intermediate position,
it will move initially to the secure position and then to the stored position after expiry of
the runtime.
Technical data
Housing: Plastic
Colour: White
Installation: Series installation on mounting rails
Protection rating: IP 20
Dimensions: approx. 107 x 88 x 60 (W x H x D, mm), 6 modules
Weight: approx. 360 g
Ambient temperature: Operation -20…+70°C, storage -55…+90°C
Ambient humidity: max. 95% rH, avoid dew
Auxiliary voltage: 230 V AC, 50 Hz
Inputs: • Central (Up/Down)
• 4 x hand switches (Up/Down buttons)
Outputs: • 4 x Drive 230 V (PE/N/Down/Up), each 4 A