Code Supply FL Amps Output kW
r/min
SCP250/4-1 230V/1Ph/50Hz 0.90 0.09 1455
SCP315/4-1 230V/1Ph/50Hz 0.90 0.09 1390
SCP350/4-1 230V/1Ph/50Hz 0.90 0.09 1330
SCP400/4-1 230V/1Ph/50Hz 1.80 0.25 1375
SCP450/6-1 230V/1Ph/50Hz 1.05 0.12 850
SCP450/4-1 230V/1Ph/50Hz 1.80 0.25 1300
SCP500/6-1 230V/1Ph/50Hz 1.55 0.18 860
SCP500/4-1 230V/1Ph/50Hz 3.60 0.55 1350
SCP560/6-1 230V/1Ph/50Hz 2.20 0.25 875
SCP560/4-1 230V/1Ph/50Hz 4.90 0.75 1350
SCP630/6-1 230V/1Ph/50Hz 6.00 0.55 850
SCP630/4-1 230V/1Ph/50Hz 7.90 1.1 1310
Code Supply FL Amps Output kW
r/min
SCP315/4-3 400V/3Ph/50Hz 0.50 0.12 1390
SCP350/4-3 400V/3Ph/50Hz 0.50 0.12 1330
SCP400/4-3 400V/3Ph/50Hz 1.40 0.37 1375
SCP450/6-3 400V/3Ph/50Hz 0.68 0.18 850
SCP450/4-3 400V/3Ph/50Hz 1.40 0.37 1300
SCP500/6-3 400V/3Ph/50Hz 0.94 0.25 830
SCP500/4-3 400V/3Ph/50Hz 1.75 0.55 1320
SCP560/6-3 400V/3Ph/50Hz 0.94 0.25 830
SCP560/4-3 400V/3Ph/50Hz 2.00 0.75 1320
SCP630/6-3 400V/3Ph/50Hz 1.90 0.55 850
SCP630/4-3 400V/3Ph/50Hz 4.30 1.5 1320
SCP710/6S-3 400V/3Ph/50Hz 1.50 0.50 720
SCP710/6D-3 400V/3Ph/50Hz
3.40 1.1 880
SCP710/4S-3 400V/3Ph/50Hz
4.30 1.5 1380
SCP800/6S-3 400V/3Ph/50Hz
1.50 0.50 620
SCP800/6D-3 400V/3Ph/50Hz
3.40 1.1 820
Code
Supply
FL Amps
Output kW
r/min
SCPA315/4-1 230V/1Ph/50Hz
0.90 0.09 1370

SCPA350/4-1 230V/1Ph/50Hz 0.90 0.09 1290
SCPA400/4-1 230V/1Ph/50Hz 1.80 0.25 1385
SCPA450/4-1 230V/1Ph/50Hz 3.00 0.37 1340
SCPA500/4-1 230V/1Ph/50Hz 4.90 0.75 1375
SCPA560/4-1 230V/1Ph/50Hz 7.90 1.1 1340
SCPA630/4-1 230V/1Ph/50Hz 7.90 1.1 1310
Code A
B
C
D
E
F
G
H
Weight kg
SCP250 250 260 265 370 320 100 73 15 6
SCP315 315 325 360 430 380 85 88 15 8
SCP350 350 360 395 485 435 85 88 15 8
SCP400 400 410 450 540 490 84 99 15 12
SCP450 450 460 500 575 535 84 99 15 13
SCP500 500 510 560 655 615 140 99 15 20
SCP560 560 575 625 725 670 140 99 20 24
SCP630 630 645 705 805 750 140 101 20 30
SCP710 710 725 765 850 810 146 101 27 30
SCP800 800 820 870 970 910 146 101 27 33
Code A
B
C
D
E
F
G
H
Weight kg
SCPA315 315 325 360 430 380 85 88 15 8
SCPA350 350 360 395 485 435 85 88 15 10
SCPA400 400 410 450 540 490 84 99 15 14
SCPA450 450 460 500 575 535 104 99 15 15
SCPA500 500 510 560 655 615 140 99 15 22
SCPA560 560 575 625 725 670 140 99 20 29
SCPA630 630 645 705 805 750 140 101 20 32
SCP

SCPA
1.0 GENERAL
1.1 It is important these Installation and Maintenance Instructions are fully adhered to.
1.2 Full details of the unit supplied are shown on the product nameplate. If in doubt about any detail
contact Elta Fans Ltd or its agents for clarification.
1.3 All electrical installation must be carried out by suitably qualified and competent
personnel in accordance with all current statutory requirements.
1.4 These instructions cover only the Elta Fans Ltd product and do not include the supply or
installation of any safety equipment that may be required e.g. adequate guarding or
protection from rotating parts and proper electrical isolation.
1.5 Any declarations made by Elta Fans Ltd about product installation and safety, are
dependant on the fan equipment being used within installations which themselves
meet the requirements of the relevant Standards and Directives of your region.
1.6 The fan is designed for use in an ambient temperature of -20oC up to +70oC fixed speed, -20oC up
to +50oC when used with a speed controller and up to 95% relative humidity. The fan is not suitable
for corrosive or explosive atmospheres.
1.7 The installer should provide easy access to the fan to facilitate future maintenance.
1.8 The installer should ensure the fan is adequately supported.
1.9 This product is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the product by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the product.
2.0 INSTALLATION
WARNING – The fan must be isolated from the power supply during installation and
maintenance. The fan must be earthed in accordance with the local regulations.
2.1 Upon receipt, the fan equipment should be visually inspected to check for any damage. Ensure that
the impeller is free to rotate.
2.2 If there are any queries concerning the fan equipment, Elta Fans Ltd should be contacted prior to
the installation.
2.3 The fan must be securely mounted in the desired position to suit the application.
The fan can be mounted at any angle.
2.4 Check the details on the motor rating plate to ensure that the correct power supply (voltage,
frequency and phase) is available.
An incorrect power supply will lead to permanent damage to the fan motor.

2.5 Refer to the appropriate wiring diagram. Ensure that all earth connections are made.
2.6 Means for electrical disconnection must be incorporated in the wiring installation in accordance with
the relevant wiring and electrical regulations.
2.7 Precaution must be taken to locate the exhaust discharge terminal so as to avoid the backflow of
gases into the room from the open flue of gas or other fuel burning appliances.
3.0 START-UP
3.1 Before power is supplied to the unit, check that the wiring is correct as per the fan connection
diagram.
3.2 At initial start-up, check that impeller rotation and airflow direction is correct.
3.3 Check that the motor amperage draw does not exceed the nameplate rating.
4.0 FAN MAINTENANCE
4.1 Inspection of the fan at least once every 12 months is recommended to ensure that the motor, fan
blades, and supporting guards, are clean. Any build up of dust and deposits on the blades or
guards should be removed using a non-abrasive cleaner.
4.2 All fastenings should be checked for tightness. In addition, all rotating items should be checked.
4.3 Bearings are of the ‘sealed for life’ type and will not need a detailed inspection.
WARNING – This fan is fitted with an auto-reset thermal contact which switches the fan off in the
event of a fault condition.
Once the motor cools down the fan may start unexpectedly.
Only a suitably qualified and competent person may carry out maintenance after the electrical
supply has been isolated.
WIRING



GUARANTEE
Elta Fans Ltd will, free of charge, within a period of 1 year from the date of despatch from their
works, repair or at its option replace any goods which are proved to have defects as a result of
defective materials or workmanship. The goods MUST be returned to Elta Fans Ltd carriage paid for
examination.
Elta Fans Ltd
17 Barnes Wallis Road
Segensworth East Industrial Estate
Fareham, Hampshire, PO15 5ST, United Kingdom
Visit: eltafans.com
e-mail: mailbox@eltafans.co.uk
Applied Technology: Tel: +44(0) 1489 566500 Fax: +44(0) 1489 566555
Building Services: Tel: +44(0) 1384 275800 Fax: +44(0) 1384 275810
Export: Tel: +44(0) 1489 566500 Fax: +44(0) 1489 566555
SCP Inst Issue 1: 29-06-07
Questo manuale è adatto per i seguenti modelli
53
Indice
Altri manuali Elta Fan

Elta
Elta ARCO D Manuale utente

Elta
Elta Multiflow SMB Manuale di istruzioni

Elta
Elta 9050N5 Manuale utente

Elta
Elta Ezifit In-Wall SEIE Manuale utente

Elta
Elta 9016N6 Manuale utente

Elta
Elta Quietflow SQS Series Manuale utente

Elta
Elta 9050N2 Manuale utente

Elta
Elta 9095N5 Manuale utente

Elta
Elta 9015 Manuale utente

Elta
Elta SAX Series Manuale utente