Enginko MCF-LW06424 Manuale utente

2022/02/16 09:16 1/2 MCF-LW06424 Operating Manual
e n g i n k o . s u p p o r t . c e n t e r - http://www.enginko.com/support/
Table of Contents
MCF-LW06424 Operating Manual 1 ...............................................................................................
1. Description 1 ................................................................................................................................
2. Overview 2 ....................................................................................................................................
2.1 Technical data 2 .........................................................................................................................
3 Installation 3 ..................................................................................................................................
3.1 Connection 3 ..............................................................................................................................
3.2 Analog inputs 4 ..........................................................................................................................
3.3 Configuration 6 ..........................................................................................................................
3.4 System led 7 ..............................................................................................................................
3.5 Firmware update 8 .....................................................................................................................
4. Setup 8 ..........................................................................................................................................
4.1 Period 8 ......................................................................................................................................
4.2 Thresholds 9 ..............................................................................................................................
4.3 Other settings 10 .......................................................................................................................
5. Diagnostic 11 ................................................................................................................................
6 LoRaWAN network 11 ...................................................................................................................
6.1 Activation 12 ..............................................................................................................................
6.2 Other settings 13 .......................................................................................................................
7 Passwords 13 .................................................................................................................................
8 General configuration file 14 ......................................................................................................
8.1 Multi devices configuration 15 ...................................................................................................
9 Payload 16 ......................................................................................................................................
10 Ordering code 16 ........................................................................................................................
11 Declaration of conformity 16 ....................................................................................................
12 FCC compliance for MCF-LW06424-US 16 ...............................................................................
13 Contacts 17 ..................................................................................................................................

Last update: 2022/02/16 09:15 manual_mcf-lw06424 http://www.enginko.com/support/doku.php?id=manual_mcf-lw06424
http://www.enginko.com/support/ Printed on 2022/02/16 09:16

2022/02/16 09:16 1/17 MCF-LW06424 Operating Manual
e n g i n k o . s u p p o r t . c e n t e r - http://www.enginko.com/support/
MCF-LW06424 Operating Manual
Important safety information
Read this manual before attempting to install the device! Failure to observe
recommendations included in this manual may be dangerous or cause a violation of the
law. The manufacturer will not be held responsible for any loss or damage resulting from
not following the instructions of this operating manual.
Do not dismantle or modify in any way.
Avoid mechanical stress
Do not use any detergent or alcohol to clean the device.
Disposal information for users
Pursuant to and in accordance with Article 14 of the Directive 2012/19/EU of the
European Parliament on waste electrical and electronic equipment (WEEE), and
pursuant to and in accordance with Article 20 of the Directive 2013/56/EU of the
European Parliament on batteries and accumulators and waste batteries.
The barred symbol of the rubbish bin shown on the equipment indicates that, at the end of its useful
life, the product must be collected separately from other waste.
Please note that the lithium batteries must be removed from the equipment before it is given as
waste and disposed separately. To remove the batteries refer to the specifications in the user manual.
For additional information and how to carry out disposal, please contact the certified disposal service
providers.
1. Description
MCF-LW06424 is able to read 4 analog inputs 4-20mA with a resolution of 12 bit. The inputs have an
insulation of 1000Vdc with respect to the power supply, and are protected against polarity inversion.

Last update: 2022/02/16 09:15 manual_mcf-lw06424 http://www.enginko.com/support/doku.php?id=manual_mcf-lw06424
http://www.enginko.com/support/ Printed on 2022/02/16 09:16
MCF-LW06424 is available with DIN rail option (MCF-DIN105):
2. Overview
2.1 Technical data
CPU Cortex M4
RTC
EEProm 32KB
Flash 1MB
Encryption AES 128 bit
LiPo 800mAh rechargeable battery
Class C LoRaWAN® stack EU868, AS923, AU915, US915
1000Vdc isolated analog inputs

2022/02/16 09:16 3/17 MCF-LW06424 Operating Manual
e n g i n k o . s u p p o r t . c e n t e r - http://www.enginko.com/support/
4 analog current inputs 4-20mA 12bits and disconnect alarm
4 programable thresholds for each channel
USB On The Go
IoT node setup ad firmware upgrade via USB interface
Power supply 10÷36Vdc
Storage temperature range -20°C ÷ +80°C
Working temperature range -10°C ÷ +70°C
Dimensions L x H X P: 81 x 60 x 50mm
3 Installation
3.1 Connection
3.1.1 Power connection as stand-alone device
Please refer to following connections:
pin Name Description
J3.9 GND Negative power supply (BLACK)
J3.10 VDD Positive power supply range [10-36Vdc] (RED)
Power can also be supplied by USB.
3.1.2 Power connection with DIN rail option
Please refer to following connections:

Last update: 2022/02/16 09:15 manual_mcf-lw06424 http://www.enginko.com/support/doku.php?id=manual_mcf-lw06424
http://www.enginko.com/support/ Printed on 2022/02/16 09:16
Power supply:
Pin Name Description
J2.1 Vdc Positive power supply range [10-36Vdc]
J2.2 GND Negative power supply
Power can also be supplied by USB.
3.1.3 Antenna
The magnetic antenna must be positioned on a metal body. It should preferably be vertical and at
least 30 cm away from other metal bodies. The installation must take place in a place where the
LoRaWAN® signal coverage is good (SF=7 optimal, SF=12 weak). Use the provided clip to hold the
antenna connector in place, as in the picture:
3.2 Analog inputs

2022/02/16 09:16 5/17 MCF-LW06424 Operating Manual
e n g i n k o . s u p p o r t . c e n t e r - http://www.enginko.com/support/
Pin Name Description Range Resolution
J1.1 AI1 Analog input 1 4-20mA 12 bit
J1.2 GA Common
J1.3 AI2 Analog input 2 4-20mA 12 bit
J1.4 GA Common
J1.5 AI3 Analog input 3 4-20mA 12 bit
J1.6 GA Common
J1.7 AI4 Analog input 4 4-20mA 12 bit
J1.8 GA Common
Current Loop (4-20mA)
Input resistance 125Ω
Absolute maximum value 24mA
Max error ±0.1%
Insulation 1000Vdc
Current values less than 3mA generate a “disconnected sensor” condition.
Caution: inputs are not galvanically isolated from each other.
3.2.1 Connection examples
1 sensor

Last update: 2022/02/16 09:15 manual_mcf-lw06424 http://www.enginko.com/support/doku.php?id=manual_mcf-lw06424
http://www.enginko.com/support/ Printed on 2022/02/16 09:16
2 sensors
3.3 Configuration
To deploy the sensor, use LoRaWEB online tool, to setup LoRaWAN® credentials and other
preferences (only available for Windows®) :
LoRaWEB Tool (iot.mcf88.cloud/LoRaWeb)
Before connect the device the first time, please install LoRaBridge applications and drivers:
https://iot.mcf88.cloud/LoRaWeb/#/download
Validate your settings reading data after the write.
enginko provides, upon free registration, user manuals, javascript examples, downlink generator,
uplink decoder, firmware updates and different tools :

Last update: 2022/02/16 09:15 manual_mcf-lw06424 http://www.enginko.com/support/doku.php?id=manual_mcf-lw06424
http://www.enginko.com/support/ Printed on 2022/02/16 09:16
Steady state Fixed
Data error Flashing 2 seconds
Connection error Flashing 1 second
3.5 Firmware update
Save the new firmware file (.exe) on the PC, run the file, select the USB FW port and start the update:
and waiting for the end message.
4. Setup
4.1 Period
Period is the interval (in minutes) between one measure and the next one. The sensor sends one
measures for every transmission. Value can be between 15 and 65535 minutes (default: 30 minutes).
Altri manuali per MCF-LW06424
1
Indice
Manuali Scheda di rete popolari di altre marche

Buffalo
Buffalo AirStation WLI-PCM-L11GP Manuale utente

National Instruments
National Instruments NI 9234 Manuale utente

Hama
Hama 49276 Manuale utente

Linksys
Linksys WCF54G - Wireless-G Compact Flash Card Manuale operativo

Compaq
Compaq Wireless LAN 100 Manuale utente

Bose
Bose PowerMatch Dante Manuale utente