Exodraft EBC10v2 Manuale utente

Fitting, installation
and operating instructions
EBC10v2
UK
EBC10v2
Read and save these instructions!

3120074 EBC10v2 UK 20190506
2
1. Specications .............................................................................................4
1.1 Dimensions and capacity ...................................................................................4
2. Product information .......................................................................................5
2.1 Accessories ................................................................................................6
2.2 Fitting .....................................................................................................6
2.2.1 Connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.3 Layout of the user interface.................................................................................8
2.3.1 Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.3.2 Terminal board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.4 Mechanical installation ................................................................................... 10
2.5 Display .................................................................................................. 11
2.5.1 Using the interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.5.2 Setting the language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.5.3 Locked home screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.6 Introduction to the user interface......................................................................... 14
2.7 Setup .................................................................................................... 15
2.7.1 Chimney draft setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.8 Pre/post-purge........................................................................................... 16
2.9 Temperature Sensor...................................................................................... 17
2.10 Quick menu for setpoint.................................................................................. 17
3. Settings and troubleshooting .............................................................................18
3.1 Error codes............................................................................................... 18
3.2 Overview of the service menu ............................................................................ 18
3.2.1 Light-emitting diodes and terminal board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.2.2 Switch between the basic functions of pressure control and supply air . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4. Pressure regulation of exodraft chimney fans ..............................................................22
4.1 Application.............................................................................................. 22
4.2 Functioning.............................................................................................. 22
4.3 Electrical connection ..................................................................................... 22
4.4 Wiring examples ......................................................................................... 22
4.4.1 One boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.4.2 Continuous operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.4.3 One boiler with potential free contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.4.4 One boiler and extra monitoring with PDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4.4.5 One boiler with potential free contact and temperature sensor input . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5. Pressure regulation of supply air fan.......................................................................28
5.1 Application .............................................................................................. 28
5.2 Mode of operation ....................................................................................... 28
5.3 Electrical connection ..................................................................................... 28
6. EU Declaration of Conformity .............................................................................29

Installation: ________________________________
Installer: _________________________________
Installation Date: ____________________________
Symbols:
The following symbols are used throughout this manual to bring attention to potential danger or to important
information about the product.
Prohibition symbol:
Failure to observe instructions marked with a prohibition symbol is associated with serious injury or death.
Danger symbol:
Failure to observe instructions marked with a danger symbol is associated with personal injury or material
damage.
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY, OBSERVE THE FOLLOWING:
• Use this unit in the manner indicated by the manufacturer. If you have questions, contact the supplier.
• Before servicing the unit: Switch of the power and ensure that no one can turn it back on accidentally.
• Installation work should be done by qualied individuals according to applicable statutory regulations.
• Follow directions of the manufacturer along with general safety guidelines.
• This unit must be grounded during installation.
Disposal:
No special disposal requirements. Disposal of this product should be carried out in accordance with statutory
regulations regarding electronic waste.
3120074 EBC10v2 UK 20190506 3

1. Specications
1.1 Dimensions and capacity
exodraft EBC10v2 Styring
Power supply V 1x 230 V / 50 Hz
Max. motor load kW/hp 0.35/0.5
Operating temperature °C -20 to 50
Selection of operations Pa 0-150
Tolerance Pa +/-5%
+24V supply mA 100 Max.
Control and alarm relay Max 230 VAC/4A AC1 - 24 VDC/2A DC1
Boiler inputs 10-48 VDC / 10-230 VAC
Output TRIAC VAC 10-230
Temperature Input Pt1000
Dimensions AxBxC 175 x 175 x 100 mm
Weight kg 1.5
IP-rating IP 54
Fuse A 4.0T
XTP-150 sensor
Power supply VDC 24 VDC(+/- 15%)
IP-Rating IP 54
Output VDC 0-10 VDC, max 10 mA
Operating temperature °C -25 to 50
Tolerance Pa +/-5%
Dimensions mm 80 x 82 x 55,5
Chimney Probe
Dimensions H mm 108
I mm 89
A
B
3120074 EBC10v2 UK 20190506
4• Technical specications

2. Product information
Description
EBC10v2 (exodraft Boiler Control) is a specially developed control component for constant pressure regulation of
chimney draft. Available in variant:
• EBC10v2EU01 is suitable for indoor installation
By changing the setup, EBC10v2 can also:
• Regulate the supply of fresh air to the boiler room (see section 4).
Guide structure
EBC10v2 can be used either to control exodraft chimney fans or to control supply air fans.
The guide is divided into six sections::
• Section 1. Specications
• Section 2. ”Product Information”.
• Section 3: Settings and Troubleshooting
Section 4: Pressure control of exodraft chimney fans (default setting).
• EBC10v2 ensures and monitors consistent pressure in the chimney.
• EBC10v2 can also be used for boiler systems with modulating burners.
• The automation monitors the draft in the chimney, disabling the burner in case of malfunction.
• The automation is designed for both solid fuel boilers, atmospheric gas boilers, and boilers with oil and
gas blow torches.
• EBC10v2 can control a chimney fan directly.
Section 5: Pressure control of supply air fan.
• EBC10v2 is used for control of a supply air fan.
• EBC10v2 ensures and monitors consistent pressure in the boiler room.
• The automation monitors the pressure in the boiler room, disabling the burner in case of malfunction.
• EBC10v2 can control a supply air fan directly.
Section 6: EU Declaration of Conformity
3120074 EBC10v2 UK 20190506 Product information • 5Product information • 5

EBC10v2 includes the following:
EBC10v2
Pos. Part Item no. Function
A EBC10v2 EBC10v2EU01 Control of exodraft chimney fans and blow fans. For indoor
installation.
B Pressure
transducer (XTP)
XTP150 Measures the air pressure in boiler room, chimney, or outdoor
atmospheric pressure.
D Measuring probe
for EBC10v2EU01
3200813 Measures pressure in the chimney.
E 2 m. Silicone hose 2000335 Supplies the pressure transducer (XTP) with reference pressure
from the measuring probe or from outdoors.
Instructions 3120070
2.1 Accessories
Part Item no. Function
Relay ES12 For connection of more than two boilers
External PDS PDSBOX Measures pressure in the chimney
Rep. switch REP-AFB Isolation switch
Measuring probe 90° 3200814 Measures pressure in the chimney (Pos. C)
2.2 Fitting
Cable length
Max. cable length between EBC10v2 and XTP: 100 m.
Max. cable length between EBC10v2 and chimney fan / fan: 100 m.
Max. cable length between XTP and measuring probe 2 m.
A
C
B
E
D
3120074 EBC10v2 UK 20190506
6 • Product information6 • Product information

2.2.1 Connection diagram
EBC10v2 is to be tted and connected as shown in the diagram below.
B1
A
A
B2
Ø 6.5
EBC10v2
RD11804
A
A
Ø 6.5
Control of. Fitting procedure
Chimney fan
Note!
• Install EBC10v2EU01 and the pressure transducer (XTP) in the boiler room.
• Fit the measuring probe (A) in the boiler ue or in the manifold. However, for atmospher-
ic boilers, the probe must always be positioned after the draft hood.
• Connect the hose from the measuring probe to the negative terminal on the pressure
transducer“B1”.
• When the measuring probe is placed outside, it must be installed in a manner that pre-
vents the formation of condensation or ice. EBC10v2EU01 comes with a straight measur-
ing probe.
• EBC10v2 must always be installed where it is protected from wind and weather (rain,
snow, etc.)
Supply air fan • Install the control and the pressure transducer (XTP) in the boiler room.
• Connect the hose for measuring reference pressure (outdoor atmospheric pressure) to
the negative terminal“B1” on the pressure transducer. Run the hose outside the building
to a place not exposed to the weather. The open end of the hose may be installed inside
a box as described at the top of the next page.
Note! • Particularly when wanting positive pressure* in the chimney / boiler room:
• Connect the hose to the positive terminal on the pressure transducer“B2”.
• EBC10v2 comes with only 2 m of hose.
Note!
*The default setting of the EBC10v2 is for negative pressure regulation, but local statutory
regulations may require constant positive pressure.
**Do not install the pressure transducer in an airtight enclosure, as it uses the atmospheric
pressure for reference..
3120074 EBC10v2 UK 20190506 Product information • 7Product information • 7

Make sure to position the pressure transducer (XTP) correctly.
Note
Do not blow into the valves of the XTP.
For outdoor installation, place the pressure transducer where it is not exposed to the weather. For outdoor
installation, the pressure transducer should be placed in a box tted with a hole (Ø2mm) in the bottom. The
hole serves to ensure correct reference pressure and prevent water entry
If the pressure transducer is positioned where insects have access to the free end, installing a sinter lter is
recommended
2.3 Layout of the user interface
2.3.1 Panel
Pos. Del Funktion
A USB • USB Interface
B Display • Shows operation and changes in the user interface (menu system)
• Indicates alarms
• shows normal operation status
C • Go forward/up in the menu system
D • Approves your action
• Forward
E • Go down in the menu system
F • Interrupt action
• Back
G Fuse • Fuse type
EBC10v2
G
B
D
E
F
A
C
3120074 EBC10v2 UK 20190506
8 • Product information8 • Product information

2.3.2 Terminal board
The following explains connection options for the terminal board
Terminal Betegnelse Terminal Use
1 PE Ground 18 Inactiv
2 Supply - L1 19 Inactiv
3Supply – N 20 Inactiv
4 Chimney fan – N 21 Inactiv
5 Chimney fan - L1 (Regulating) 22 XTP-0V DC power supply
(transducer)
6 Chimney fan - PE Ground 23 XTP-24V DC power supply
(transducer)
7 Frequency converter relay NO 24 Inactiv
8 Inactiv 25 Inactiv
9 Inactiv 26 Inactiv
10 Alarm Out - NO 27 0V DC Power supply
11 Alarm Out - C 28 24 VDC power supply (Max.
100 mA)
12 Voltage input from appliance /
boiler 1 thermostat optocoupler
(+) (10-230V AC/DC
29 24 VDC power supply (Max.
100 mA)
13 Voltage input from appliance /
boiler 1 thermostat optocoupler
(-) (10-230V AC/DC
30 PDS-NC (normally closed)
Proven draft switch
14 Burner 1 relay switch-Normally
open (max. 230 VAC, 2 amps.)
31 PDS-NO (normally open) Prov-
en draft switch
15 Burner 1 relay switch-Common
(max. 230 VAC, 2 amps.)
32 PDS-C (shared) Tested draft
switch
16 Inactiv 33 Pt1000
17 Inactiv 34 Not used
35 Pt1000
* However, terminals 30, 31, and 32 may be used for connecting other auxiliary monitoring equipment as well.
3120074 EBC10v2 UK 20190506 Product information • 9Product information • 9

2.4 Mechanical installation
The control and the transducer must be installed inside, preferably in the boiler room. The control does not need to be
installed in a cabinet.
100 m
2 m
EBC10v2 Control
EBC10v2
Do not install the transducer in an airtight enclosure. It uses the boiler room pressure / atmospheric pressure
as reference pressure.
The control can be installed directly on the wall or somewhere similar.
Take o the lid.
The installation holes are placed under the plastic screws keeping the cover in place.
The distance between the control and the transducer should not exceed 100 m.
EBC10v2
3120074 EBC10v2 UK 20190506
10 • Product information10 • Product information
Altri manuali per EBC10v2
1
Indice
Altri manuali Exodraft Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente


















