Pulse Access, External Power
& Scaled Pulse Module
FOR USE WITH ALL TURBINE METERS WITH Q9 DISPLAY
09/2021 920909-01 Rev. C

2
Please save these instructions for future reference. Read carefully before attempting
to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with
instructions could result in personal injury and/or property damage.
Please refer to back cover for information regarding this product’s warranty and other
important information.
DO NOT RETURN THIS PRODUCT TO THE STORE!
Please contact Great Plains Industries, Inc.® before returning any product. If you are
missing parts, or experience problems with your installation, contact our Customer
Support Department. We will be happy to assist you.
Call 888-996-3837 or 316-686-7361
Email [email protected]
SAVE FOR YOUR RECORDS
Model #: ______________________________
Serial #: ______________________________
Purchase Date: ________________________

3
TABLE OF CONTENTS
Getting Started --------------------------------------------- 4
Electrical / Mechanical Specifications ---------------- 5
Approval Ratings ------------------------------------------ 7
Installation --------------------------------------------------- 8
Installing Module ------------------------------------- 8
Wiring --------------------------------------------------- 9
Operation / Calibration ---------------------------------- 12
Troubleshooting ------------------------------------------ 13
Pulse Output Flowchart --------------------------- 14
Parts List --------------------------------------------------- 15
Parts & Service ------------------------------------------- 15
Warranty --------------------------------------------------- 16

4
BEFORE YOU BEGIN
Usage Requirements
•This Pulse Access, External Power & Scaled Pulse module is not FM
Approved. Therefore, use of this module with an approved metering system
voids FM Approval.
•This module is designed for use with all meters that are equipped with the
Q9 display option. The PA-EP-SC module can be field calibrated through
the configuration menu options on the Q9 display.
Power Source Requirements
•
This module requires an input power of 5.0-26 VDC (24 VDC is
recommended).
UNPACKING / INSPECTION
Inspect
•After unpacking the unit, inspect carefully for any damage that may have
occurred during transit. Check for loose, missing or damaged parts.
Shipping damage claims must be filed with carrier.
•See General Safety Instruction, and all Cautions, Warnings, and Dangers
as shown.

5
SPECIFICATIONS
MECHANICAL
Housing
Material Nylon 6-6
Strain Relief
Hubble
PG7.
Grip
range
0.11
-
0.26
Housing Port Thread
Female 1/2
-
20 UNF
-
2B (Compatible with PG7)
Cable
Belden 9363 (22 AWG
-
3 conductor
with drain wire and shield)
Cable Length
10 ft
.
(3m), provided
Operating
Temperature 0° to +140°F (-18° to +60°C)
Higher Process Fluid
Temperatures
Obtainable with G2
Stainless Steel
Meters
When
i
nstalled on G2
S
tainless Steel Flowmeters,
s
ee
Ambient and Fluid Temperature Limits graph on next
page for higher process fluid temperature Limits.
If wider process fluid temperature ranges are desired,
reference information on FLOMEC® Remote Kits.
Storage
Temperature -40° to +180°F (-40° to +82°C)
POWER
Voltage Minimum
5.0 VDC
Voltage Maximum
26 VDC
Isolated
No
PULSE OUTPUT
Type
Open Collector (NPN)
*
External Pull
-
u
p
Voltage 5.0 to 26 VDC
**
Internal Pull
-
u
p
Voltage 5.0 to 26 VDC
* Note: Customer supplied external voltage with separate power supply and a minimum
external pull up resistance of 820 ohms.
** Note: When configured for internal pull up resistor, no external pull up resistor is required.
Internal pull up is fixed at 100K ohm.

6
SPECIFICATIONS (continued)
AMBIENT AND FLUID TEMPERATURE LIMITS
NOTE: The upper limit of the “Useable Combination” area can be increased by 10°F (6°C)
when lithium batteries are installed in the Q9 Display.

7
SPECIFICATIONS (continued)
DIMENSIONS
Length
(A)
Height
(B)
Width
(C)
Strain Relief
(D)
3.45 in.
(8.8 cm)
0.90 in.
(2.3 cm)
2.18 in.
(5.5 cm)
0.77 in.
(1.96 cm)
Module shown installed on G2 1” stainless steel flowmeter
Figure 1
APPROVAL RATINGS

8
INSTALLATION
INSTALLING MODULE
1. Remove the display electronics from the front of the turbine.
NOTE: If you are installing more than one module at a time, take care to keep the
proper electronics paired with the original turbine.
2. If your display currently has batteries installed, you will need to remove them to
enable the scaled pulse output to function.
3. Disconnect 2-pin coil connector from display. Make sure coil remains firmly attached to
meter body (DO NOT pull on wires or attempt to remove from meter body).
4. Connect the module to the 10-pin connector located on the backside of the computer
electronics (see Figure 2).
5. Reconnect the coil connector to the 2-pin terminal block on the other end of the
computer backside. Once the cables are installed on the display, the housing of the
display can be placed on top of the module (see Figure 2).
6. Install the computer electronics to the front side of the turbine. Tighten the four screws
snugly.
Module shown installed on G2 1” stainless steel flowmeter
Figure 2

9
INSTALLATION (continued)
WIRING
The Pulse Access module comes pre-wired for external connections to external power and
provides an open collector output, which can be set for either raw or scaled pulse output. The
wires are color-coded and are to be connected as shown in Figures 3 & 4.
Wire Color Feature
Red VCC
Black GND
White Pulse Out
NOTE: The pulse output is set to raw pulse output as the default setting on the Q9 display.
If your application requires a scaling of the pulse output, refer to the installation instructions to
enable the scaled pulse feature and refer to the Q9 owner’s manual for instructions on the
configuration of the scaled pulse feature.
NOTE: If using the scaled pulse output feature, use the scaled K-factor in the user interface
device.
Figure 3

10
INSTALLATION (continued)
WIRING (continued)
NOTE: The internal and external options for the pull up resistance and voltage is selectable
by the header on the pulse access board (see Figures 4a & 4b).
When the Jumper is on the top two pins, the “external resistor required” option is selected
(Figure 4a). This external resistor can be installed as shown on Figure 3, but could also be
built into the existing customer equipment.
When the Jumper is located on the bottom two pins, the “internal resistor” option is selected
(Figure 4b).
Figure 4a Figure 4b
Altri manuali per G2
1
Indice
Altri manuali Flomec Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente