Flowserve GESTRA GAV 54F Manuale

1
GAV 54F
Installation & Operating
Instructions 819025-00
English
Shut-Off Valve
E N

2
Contents
Important Notes
Usage for the intended purpose .................................................................................... 4
Safety note .................................................................................................................. 4
Danger........................................................................................................................ 4
Attention ..................................................................................................................... 4
PED (Pressure Equipment Directive) .............................................................................. 4
ATEX (Atmosphère Explosible)....................................................................................... 4
Explanatory Notes
Scope of supply ........................................................................................................... 5
Description .................................................................................................................. 5
Function...................................................................................................................... 5
Attention ..................................................................................................................... 5
Danger........................................................................................................................ 5
Technical Data
Pressure & temperature ratings .................................................................................... 6
Attention ..................................................................................................................... 6
Corrosion resistance .................................................................................................... 6
Design
GAV 54F...................................................................................................................... 7
Key ............................................................................................................................. 7
Installation
GAV 54F...................................................................................................................... 8
Attention ..................................................................................................................... 8
Danger........................................................................................................................ 8
Attention ............................................................................................................... 8 – 9
Danger........................................................................................................................ 9
Attention ..................................................................................................................... 9
Installation notes.......................................................................................................... 9
Danger...................................................................................................................... 10
Commissioning Procedure
GAV 54F ................................................................................................................... 10
Danger...................................................................................................................... 10
Attention ................................................................................................................... 11
Functional test ........................................................................................................... 11
Attention ................................................................................................................... 11
Page

3
Contents
Maintenance
GAV 54F.................................................................................................................... 12
Attention ................................................................................................................... 12
Danger...................................................................................................................... 12
Spare Parts
GAV 54F.................................................................................................................... 13
Attention ................................................................................................................... 13
Decommissioning
Danger...................................................................................................................... 13
Disposal .................................................................................................................... 13
Transport and Storage
Transport................................................................................................................... 14
Attention ................................................................................................................... 14
Storage ..................................................................................................................... 14
Hoisting the valve for installation into horizontal pipeline ............................................... 15
Hoisting the valve for installation into vertical pipeline................................................... 15
Page

4
Usage for the intended purpose
Use the shut-off valve GAV 54 F only for isolating and throttling neutral gases, steam,
vapours and liquids within the specified pressure and temperature ratings and check the
corrosion resistance and chemical suitability for the application in question.
Safety note
The equipment must only be installed and commissioned by qualified and competent staff.
Retrofitting and maintenance work must only be performed by qualified staff who –
through adequate training – have achieved a recognised level of competence.
Danger
The valve is under pressure during operation.
When loosening flanged connections, sealing plugs or stuffing box connections,
hot water and steam will escape.
This presents the risk of severe scalding all over the body!
Before carrying out installation and maintenance work make sure the system is
depressurized. Isolate the valve from both upstream and downstream pressure.
The valve becomes hot during operation. Risk of severe burns to hands and arms.
Before carrying out installation and maintenance work make sure that the steam
trap is cold.
Sharp edges on parts present a danger of cuts to hands.
Always wear industrial gloves when replacing valves or parts of valves.
Danger of bruising! During operation moving parts can pinch one's hands or fingers,
causing severe injuries. Do not touch moving parts.
Attention
The name plates specify the technical properties of the devices.
Do not commission or operate any item of equipment that does not bear its specific name
plate.
PED (Pressure Equipment Directive)
The equipment fulfills the requirements of the Pressure Equipment Directive PED 97/23/EC.
For use with fluids of group 1 and 2.
With CE marking (apart from equipment that is excluded from the scope of the PED as
specified in section 3.3).
ATEX (Atmosphère Explosible)
The equipment does not have ist own potential source of ignition and is therefore not
subject to the ATEX Directive 94/9/EC. Applicable in Ex zones 1, 2, 21, 22 (1999/92/EC).
The equipment is not Ex marked.
Important Notes

5
Explanatory Notes
Scope of supply
GAV 54F
1 Shut-off valve GAV 54F
1 Installation manual
Description
Maintenance-free bellows-sealed shut-off valve with straight-through body, flanged to
EN 1092-2. The shut-off valve is equipped with a stainless steel bellows seal
and a safety stuffing box made from pure graphite.
Shut-off valves from DN 15 to DN 100 are fitted with a throttling plug as standard.
DN125 to DN300 valves come with a flat plug as standard. The handwheel features a
non-rising stem and a
locking device.
Function
To close the shut-off valve turn handwheel to the right and to open it turn handwheel to the
left. Direction symbols are found on the top of the handwheel.
The valve stem is sealed off by means of a stainless steel bellows and a safety
stuffing box made from pure graphite.
Use the locking device to lock the handweel in place by turning it to the right until it hits
the stop. When supplied the handwheel is not locked in place.
Attention
Incorrect operation of the valve may have a substantial impact on the entire system, for
example:
Leakage of the fluid
System / machine brought to a standstill
Impairment / reduction / increase of the system's / machine's function / effect
Danger
When delivered ex factory, the safety stuffing box is not fully tightened. In the event of the
bellows failure, the stuffing box screws (safety stuffing box) must be tightened in order to
avoid fluid leakage (observe dange note on page 4!). The stem seal with bellows is main-
tenance free.

6
Technical data
Pressure & temperature ratings
GAV 54F, flange PN 16, EN 1092-2
PS (max. admissible pressure) [barg] 16 16 14.4 12.8 11.2 9.6
TS (max. admissible temperature) [°C] 20 120 150 200 250 300
PS (max. admissible pressure) [psig] 232 232 208 185 162 139
TS (max. admissible temperature) [°F] 68 248 302 392 482 572
ΔP (admissible differential pressure) [bar] 16
[psi] 232
Attention
If the following differential pressures are exceeded, a pressure balance plug is required.
DN 200 250 300
ΔP (admissible differential
pressure)
[bar] 12 9 6
[psi] 174 130 87
The pressure balance plug only takes effect when pressures builds up above the valve
plug. As a consequence, the flow through the valves is reversed. Note that the embossed
flow direction arrow is reversed.
Corrosion resistance
If the equipment is used for the intended purpose, its safety is not impaired by corrosion.

7
Design
GAV 54F
0
9
8
7
6
5
4
3
2
1
Key
1Handwheel
2Stem
3Body cover
4Gland packing
5Hexagon-head screws
Fig. 1
6Joint ring
7Bellows
8Valve plug
9Seat ring
0Body

8
GAV 54F
Responsibility for positioning and installing the valves always lies with the engineering
company, construction company or operator/user. Planning and installation errors may
impair the reliable function of the valves and pose a substantial safety hazard.
For this reason it is particularly important to observe the following:
Attention
The piping must be laid such that detrimental thrust and torsional forces are kept away
from the valve body during installation and operation to avoid both leakage and damage to
the body.
The caps on the connection ports, if any, shall be removed immediately prior to installation.
The mating flange faces must be clean and undamaged .
Danger
The gaskets on the flange faces must be properly centered.
Only fasteners (for ex. to DIN EN 1515-1) and flange gaskets (for ex. to DIN EN 1514)
made of materials suitable for the respective valve size may be used.
For the flange connection between valve and pipe use all flange bolt holes provided.
Attention
When using steel flanges to DIN EN 1092-1 in conjunction with cast iron valves with
flanges machined to DIN EN 1092-2, make sure that for nominal diameter
DN 65 the mating flanges are fitted offset by 22.5° to prevent an oblique position of the
valve.
This procedure is required by the difference in the number of bolt holes: DIN EN 1092-1
specifies 8 holes for steel, whereas DIN EN 1092-2 specifies only 4 holes for cast iron.
DN 65 (steel / steel):
DIN EN 1092-1 with DIN EN 1092-1,
Bolts through 8 holes
DN 65 (steel / cast iron):
DIN EN 1092-1 with DIN EN 1092-2,
Bolt hole circle to DIN EN 1092-1 turned
through 22.5°, bolts through 4 holes,
4 holes free
Installation
Fig. 2

9
Attention - continued -
When the valve is installed outdoors, sufficient weather protection must be provided to
prevent corrosion and other damage caused by penetrating moisutre.
When painting pipes or equipment, do not apply paint to the stem and plastic components
(valve function will be impaired).
If construction work is still in progress, the valves must be protected against dust, sand
and building material (cover with suitable material).
Neither the valve nor its actuating elements (e. g. handwheel, actuator, cover) must be
subjected to excessive loads (e. g. used as footholds).
The valve body and/or cover must not be subjected to any sudden impacts (with tools, for
example) as they could be destroyed.
Danger
For safety reasons, valves and piping systems operated at high (> 50 °C) or low (<0 °C)
temperatures must be insulated, or a warning sign must point out the risk of personal
injury involved when touching the hot or cold components.
Attention
If there is a risk of condensation water or ice formation, for example in air-conditioning,
cooling and refrigerating systems, it is important to ensure that the complete valve
including handwheel, if required, is provided with a proper diffusion-tight insulation. The
formation of ice introduces the risk of actuator blocking.
Installation Notes
Flow through shut-off valves should be in the direction of the embossed arrow on the valve
body. An alternating direction of flow is permissible with the standard plug but not with
the pressure balance plug. If equipment from DN 200 exceeds the following differential
pressures, a pressure balance plug is required.
DN 200 250 300
ΔP (admissible differential
pressure)
[bar] 12 9 6
[psi] 174 130 87
The pressure balance plug only takes effect when pressures builds up above the valve
plug. As a consequence, the flow through the valves is reversed (the embossed flow
direction arrow is reversed).
Installation - continued -

10
Danger
The valves should not be installed with the stem pointing downwards to prevent dirt
deposits between the folds of the bellows which might cause valve failure.
In steam service, the valve must not be installed with the stem pointing downwards
(risk of steam hammer due to condensate collecting in the valve neck).
Shut-off valves must be installed in the line so that the fluid enters the valve beneath
the disc and flows out above the disc. However, they can also be installed in lines with
alternating flow.
If the valves are to be used for throttling applications, a throttling valve disc (standard
variant DN 15 – 100) must be used.
In valves with pilot plug, the flow direction must correspond to the direction indicated by
the arrow on the valve. Valves with pilot plug must always be installed so that the pressure
to be sealed off lies above the plug.
Installation - continued -
GAV 54F
Prior to commissioning / start-up compare the material, pressure and temperature data
on the valves with the operating conditions of the piping to check the material's chemical
resistance and stability under load.
Danger
Venting the valve by undoing the bonnet / cover bolting or removing the stuffing box
packing is dangerous and therefore not permitted.
It is generally not allowed to use lamellar graphite cast iron (EN-JL1040) in systems where
surge pressures might develop, since this material does not withstand pressure surges
and, therefore, the valves may be damaged or destroyed. In such cases valves made of
nodular cast iron (EN-JS1025) or steel shall be used.
In new systems and particularly after repair, the complete piping must be thoroughly
flushed with the valves fully opened so that particles and/or welding beads that might
damage the seat/disc interface are removed.
Valve actuation
Viewed from above, the valve is closed with a clock-wise turn of the handwheel, and
opened with a counter-clockwise turn.
Direction symbols are found on the top of the handwheel.
Commissioning Procedure
Indice
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente