FS S3410-24TS-P Manuale utente

S3410-24TS-P/S5860-24XB-U
Quick Start Guide
24-PORT GIGABIT L2+/L3 POE
MANAGED SWITCHES
PoE
Status M1 M2 PWR1PWR2 PoE
1 2 3 4 5 6 7 8 910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
24 25 2623
Green=1000M Yellow=10/100M On=Link Flashing=ACT PoE LED:Green=Good Supply Yellow=OverLoad
CONSOLE
SFP+
S3410-24TS-P
PoE+
S5860-24XB-U
29 30 31 32
25 26 27 28
13 14 15 16 17 18 19 20 21 22 23 24
Yellow=OverLoad
5678910 11 12
On=Link Flashing=ACT PoE LED Mode:Green=GoodSupplyYellow=100M
1234
Green=10G/5G/2.5G/1G
MGMT
SYS PWR FAN PoE
PoE FUNC
CONSOLE
V1.1

Introduction
Accessories
S5860-24XB-U
S3410-24TS-P
Thank you for choosing S3410-24TS-P & S5860-24XB-U POE Switches. This guide is designed
to familiarize you with the layout of the switches and describes how to deploy the switches in your
network.
Grounding Cable x1
Power Cord x2
M4 Screw x8
Rubber Pad x4
Mounting Bracket x2
PoE
Status M1 M2 PWR1PWR2 PoE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
24 25 2623
Green=1000M Yellow=10/100M On=Link Flashing=ACT PoELED:Green=Good Supply Yellow=OverLoad
CONSOLE
SFP+
S3410-24TS-P PoE+
MGMT
SYS PWR FAN PoE 1 2 3456 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
PoE FUNC
S5860-24XB-U
Green=10G/5G/2.5G/1G On=Link Flashing=ACT PoE LED Mode:Green=Good Supply Yellow=OverLoad
CONSOLE Yellow=100M
NOTE: S3410-24TS-P & S5860-24XB-U POE switches have dust plugs delivered with
them. Keep the dust plugs properly and use them to protect idle optical ports.

S5860-24XB-U
S3410-24TS-P
Hardware Overview
Front Panel Ports
PoE
Status M1 M2 PWR1 PWR2 Po E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
24 25 2623
Green=1000M Yellow=10/100M On=Link Flashing=ACT PoELED:Green=Good Supply Yellow=OverLoad
CONSOLE
SFP+
S3410-24TS-P PoE+
CONSOLE
MGMT
USB CONSOLE
USB RJ45
RJ45 SFP+ SFP28
RJ45/SFP Combo SFP+
Ports Description
RJ45
SFP+
RJ45/SFP Combo
USB
CONSOLE
10/100/1000BASE-T ports for Ethernet connection
One RJ45 port and one SFP slot, with one port active at a time
SFP+ ports for 1/10G connection
Reserved
An RJ45 console port for serial management
MGMT
SYS PWR FAN PoE 1 2 3456 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
PoE FUNC
S5860-24XB-U
Green=10G/5G/2.5G/1G On=Link Flashing=ACT PoE LED Mode:Green=Good Supply Yellow=Over Load
CONSOLE Yellow=100M

S5860-24XB-U
S3410-24TS-P
Front Panel Buttons
MGMT
SYS PWR FAN PoE 1 2 3456 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
PoE FUNC
S5860-24XB-U
Green=10G/5G/2.5G/1G On=Link Flashing=ACT PoE LED Mode:Green=Good Supply Yellow=Over Load
CONSOLE Yellow=100M
PoE
Status M1 M2 PWR1 PWR2 Po E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
24 25 2623
Green=1000M Yellow=10/100M On=Link Flashing=ACT PoELED:Green=Good Supply Yellow=OverLoad
CONSOLE
SFP+
S3410-24TS-P PoE+
PoE
Ports Description
RJ45
SFP28
SFP+
USB
CONSOLE
MGMT
100M/1G/2.5G/5G/10G ports for Ethernet connection
SFP+ ports for 1/10G connection
SFP28 ports for 10/25G connection
A USB management port for software and conguration backup and
oine software upgrade
An RJ45 console port for serial management
Button Description
PoE
PoE FUNC
Switch the display mode between PoE mode and switch mode.
Button Description
PoE
FUNC
Switch the display mode between PoE mode and switch mode.
NOTE: Press PoE Mode Switch-Over Button to switch the display mode between PoE mode
and switch mode.
The switch will restart after you press the FUNC button for more
than ve seconds and wait for another ten seconds.
An out-of-band Ethernet management port

M1SFANI-F
Status
M1SFANI-F
Status
M1SFANI-F
Status
FAN1 FA N2 FA N3 PWR1 PWR2
Input
Output
Input
Output
S5860-24XB-U
S3410-24TS-P
S3410-24TS-P
Back Panels
1
Power
2
Input
Module1 Module2
Output
Input
Output
Dual Power Supplies
Expansion Module Slot
Grounding Point Fan Slot
Grounding Point
Front Panel LEDs
PoE
Status M1 M2 PWR1 PWR2 Po E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
24 25 2623
Green=1000M Yellow=10/100M On=Link Flashing=ACT PoELED:Green=Good Supply Yellow=OverLoad
CONSOLE
SFP+
S3410-24TS-P PoE+
RJ45
Status
M1
M2
PWR1
PoE
PWR2
SFPPoE (1-24)
SFP+
LEDs DescriptionStatus
Status
O Switch is not receiving power.
System is being initialized. Continuous blinking indicates
errors.
The switch is operational.
Temperature warning, check the working environment of
the switch immediately.
Switch is faulty.
Blinking Green
Solid Green
Solid Yellow
Solid Red
Dual Power Supplies

LEDs DescriptionStatus
M1/M2
O
Solid Green
Solid Green
Solid Yellow
PWR1/PWR2
PoE
RJ45
SFP
O
Solid Green
Solid Red The power module is in place but the AC power cord or
switch is abnormal.
The power supply is operational.
The power module is not in place.
O
Indicates the PoE state.
The port is not connected.
Solid Green The port is connected at 1000 Mbps.
Blinking Green The port is receiving or transmitting trac at 1000 Mbps.
Solid Yellow
O
Solid Green
Solid Yellow
The port is connected at 10/100 Mbps.
Blinking Yellow
Solid Yellow
Blinking Yellow
The port is receiving or transmitting trac at 10/100 Mbps.
O The port is not connected.
The port is not connected.
Solid Green The port is connected at 1000 Mbps.
Blinking Green
O
Solid Green
Blinking Green
The port is receiving or transmitting trac at 1000 Mbps.
The port is connected at 100 Mbps.
The port is receiving or transmitting trac at 100 Mbps.
Indicates the switching state.
There is no expansion module or the expansion module is
not correctly installed.
The expansion module is correctly installed.
PoE (1-24)
PoE is not enabled.
PoE is enabled. The port is operational.
The port has a PoE fault of overload.
SFP+
The port is connected.
The port is receiving or transmitting trac at 10Gbps.

S5860-24XB-U
MGMT
SYS PWR FAN PoE 1 2 3456 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
PoE FUNC
S5860-24XB-U
Green=10G/5G/2.5G/1G On=Link Flashing=ACT PoE LED Mode:Green=Good Supply Yellow=Over Load
CONSOLE Yellow=100M
LEDs DescriptionStatus
SYS
O
O
The system is powered o.
1.A system fault occurs.
2.The temperature reaches the upper limit.
Initialization is in progress.
The system works properly.
The locator takes eect. It is controlled by O&M personnel
remotely.
1.The temperature reaches the threshold value.
2.Dierent power modules are used together.
Blinking Green
Solid Green
Solid Green
Solid Green
Solid Green
Solid Yellow
O
Blinking Green
Solid Green
Solid Yellow
Blinking Yellow
Solid Yellow
Solid Blue
RJ45
PoE (1-24) SFP+
SFP28
MGMT
MGMT
SYS
PWR
PWR
FAN
FAN
PoE
PoE
Solid Red
Solid Red
Solid Red
Both power modules are NOT in the position.
The power module works properly.
1.A power fault occurs.
2.No AC power cable is plugged in.
3.The power model does not match.
The fan works properly.
1.A fan fault occurs.
2.The fan model does not match with the system.
3.Not all fans are in position.
Indicates the switching state.
Indicates the PoE state.
The MGMT port is NOT connected.
The MGMT port is connected at 1000Mbps.
The MGMT port is transmitting or receiving data at 1000Mbps.
The MGMT port is connected at 10/100Mbps.
The MGMT port is transmitting or receiving data at 10/100Mbps.

M1SFANI-F
Status
M1SFANI-F
Status
M1SFANI-F
Status
FAN1 FA N2 FA N3
PWR1 PWR2
Input
Output
Input
Output
Installation Requirements
Before you begin the installation, make sure that you have the following:
Category 5e or higher RJ-45 Ethernet cables, ber optical cables and console cable for
connecting network devices.
Phillips screwdriver.
Related electric cables and optical cables.
Standard-sized, 19" wide rack with a minimum of 1U height available.
O
O
O
O
Blinking Green
Blinking Green
Blinking Green
Solid Green
Solid Green
Solid Green
Solid Green
Yellow
Blinking Yellow
Back Panel LED
FAN Indicator
LEDs DescriptionStatus
RJ45
The RJ45 port is NOT connected.
The RJ45 port is connected at 1G/2.5G/5G/10G.
The RJ45 port is transmitting or receiving data at
1G/2.5G/5G/10G.
The RJ45 port is connected at 100Mbps.
PoE works properly.
PoE is o.
A PoE fault or overload occurs.
The RJ45 port is transmitting or receiving data at 100Mbps.
PoE
(
1-24)
Solid Yellow
SFP+
The SFP+ port is NOT connected.
The SFP+ port is connected at 10G/1G.
The SFP+ port is transmitting or receiving data at 10G/1G.
SFP28
The SFP28 port is NOT connected.
The SFP28 port isconnected at 25G/10G.
The SFP28 port is transmitting or receiving data at 25G/10G.
S5860-24XB-U

PoE
Status M1 M2 PWR1PWR2 PoE
1 2
2
3456 7 8 9 10 11 12
12 14 24
13 14 15 16 17 18 19 20 21 22 23 24
Green=1000M Yellow=10/100MOn=Link Flashing=ACT PoE LED:Green=Good Supply Yellow=Over Load
Console
25F 26F 27F
RG-S2910-24GT2XS-UP-E
SFP+
PoE
Status M1 M2 PWR1 PWR2 PoE
12345678910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Green=1000M Yellow=10/100M On=Link Flashing=ACT PoE LED:Green=Good Supply Yellow=OverLoad
CONSOLE
Site Environment:
Desk Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on a desk.
PoE
Status M1 M2 PWR1 PWR2 PoE
12345678910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
24 25 26
23
Green=1000M Yellow=10/100M On=Link Flashing=ACT PoE LED:Green=Good Supply Yellow=OverLoad
CONSOLE
SFP+
S3410-24TS-P
PoE+
Mounting the Switch
Do not operate it in an area that exceeds an ambient temperature of 50°C.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Ensure rack and working platforms are well earthed.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Do not install the equipment in a dusty environment.

1. Secure the mounting brackets to the two sides of the S3410-24TS-P switch with eight M4 screws.
(S5860-24XB-U switch with six M4 screws by default, another 2 screws for redundant.)
Rack Mounting
RG-S2910-24GT2XS-UP-E
2. Attach the switch to the rack using four M6 screws and cage nuts.
SYS
24 25 26
23
SFP+
C3440-24T2F2SP PoE+
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali FS Interruttore

FS
FS S3400-48T6SP Manuale utente

FS
FS S3900 Series Manuale utente

FS
FS S3150-8T2FP Manuale utente

FS
FS S5800-48F4S Manuale utente

FS
FS S3150-8T2FP Manuale utente

FS
FS S5500-48T8SP Istruzioni operative

FS
FS S5810 Series Manuale utente

FS
FS STP Series Manuale utente

FS
FS S1900-16T Manuale utente

FS
FS S3150-8T2FP Manuale utente

FS
FS SC9405 Series Manuale utente

FS
FS S3700-24T4F Manuale di istruzioni

FS
FS S2800S Series Manuale utente

FS
FS N9510-64D Manuale utente

FS
FS S3150-8T2FP Manuale utente

FS
FS S58 Series Manuale utente

FS
FS S3700-24T4F Manuale di istruzioni

FS
FS S3950-4T12S-R Manuale utente

FS
FS S5850-24XMG-U Series Manuale utente

FS
FS S3200 Series Manuale utente