Genie CT10 Manuale utente

User Manual
Please read these instructions carefully before operating the unit
and keep for further reference.
Coaxial and UTP Cable Tester
CT10

ii
Intro Section
Please read this instruction carefully before operating the product and keep it for
further reference. All examples and pictures used here are for reference only.
The contents of this manual are subject to change without notice.
CAUTION:
• Make sure to read this user’s manual thoroughly before using this product.
• Keep this user’s manual to use this product properly.
• Avoid installing places as: over 50°C or below -10°C / near rain, snow or high
humidity / near oil or gas / with vibration or shock / exposed to direct sunlight
or outside / near strong magnetic, high frequency(RF) or power cables. It may
reduce the performance or cause malfunction of the product.
• If this product is left unused or uncharged for a long time, the performance of
battery may degrade. Regular charging is recommended.
• Do not disassemble the product or put foreign materials such as metallic
objects.
• Do not connect and use any device above rated capacity of this product. It may
cause malfunction or fire.
• The warranty period of battery is 6 months after the date of purchase.
• When replacing battery, do not disa ssemble the product arbitrarily. Please
contact our service center.
• Li-ion Polymer battery (3.7V / 900mAh) is built in the product. Do not
disassemble or short circuit (short) the battery.
• When charging the product, make sure to check the operational power supply
voltage before inputting power.
• Strong shock or vibration may cau se device failure, so use with caution.
• If you let the product in abnormal state as smoke or smell, it may cause fire or
electric shock. In this case, stop operating the product and contact the place of
purchase or our service center for professional advice.
• Measuring media (cable) should be coaxial & UTP cable.
• Refer to the user’s manual for problems or questions besides above. Contact
our service center if you need assistance from a professional technician.
• Do not use the car USB charger as it may explode due to high temperature. (Do
not keep this device in the vehicle because there is a risk of explosion due to
high temperature inside the car in summer when charging with the car USB.

Contents
iii
1.0 Introduction..........................................................................................................4
1.1 Product Features...........................................................................................4
1.2 Packing .........................................................................................................4
1.3 Specification.................................................................................................5
1.4 Product Dimensions .....................................................................................5
2.0 Product Parts and Functions ...............................................................................6
3.0 Menu.....................................................................................................................7
3.1 Measure Menu...............................................................................................7
3.2 Type: Measurement Mode Type Setting (BNC, RJ45) .................................9
3.3 Cable Length: Cable Length and Status (Open, Short) Measurement ......9
3.4 Calibration ...................................................................................................13
3.5 Load Data.....................................................................................................14
3.6 Loop Resistance: Measure Coaxial Cable Loop Resistance .......................15
3.7 Unit Setting ..................................................................................................16
3.8 Setting .........................................................................................................16
4.0 Battery Status Indicator.......................................................................................17
5.0 Connection Diagram and Connectors ................................................................19
5.1 How to Use BNC to TB Connector and BNC to RJ45 Connector ...............19
5.2 How to Measure Loop Resistance of Coaxial Cable...................................19
5.3 How to Measure Cable Length by using BNC to TB Connector ................20

4
The Genie CT10 is a coaxial and UTP cable tester and is a “must have” accessory
for the professional installer. Operating for up to 3 hours continuously from fully
charged (6 hours for coaxial), this extremely useful device will detect faults up to
200m on UTP cable and up to 1.8km (RG-6) for coaxial. The CT10 is very simple to
operate with a clear 1.5” high definition display.
1.1 Product Features
• Coax / UTP cable tester, cable length and mapping, open, short status check
• Measuring Coax cable up to 1.8km, UTP cable up to 200m, measure UTP cable
up to 600m with BNC to RJ45 connector (1p)
• 1.5” high definition OLED display
• Cable loop resistance measurement function
• Calibration function : add the measurements of your own cable data, maximum
storable cable data : Coax: 8, UTP: 8
• Built-in rechargeable battery for up to 3 hours in continuous use
• Built-in basic cable data, various cable data built-in (Coax: 8 types, UTP: 4
types)
1.2 Packing
USB charging cable, carry case, BNC to TB connector, BNC to RJ45 connector and BNC-A-JJ
are supplied as a one one-time consumable item and are able to be purchased separately.
• Use USB 2.0 Mini Type Type-B Plug for USB charging cable
• Regular charging is required, as battery may discharge and degrade when the product
is uncharged for a long time.
• Battery is a consumable item. (The warranty period of the battery is 6 months. If
performance of battery degrades, it is able to be replaced in a service centre.)
• Car USB charging is not guaranteed. (Do not keep the product in vehicle.)
1.0 Introduction
CT10
User Manual
Carry Case BNC to TB
Connector
BNC-A-JJ BNC to
RJ45
Connector
USB Charging Cable

User Manual Coaxial and UTP Cable Tester
5
1.3 Specification
1.4 Product Dimensions
Functions
Display 1.5” OLED
Cable Test Type BNC Coaxial / RJ45 UTP (T568A, 568B)
Maximum Length –
Coax Cable 10m ~ 1.8km (RG-6)
Maximum Length –
UTP Cable 5m ~ 200m (UTP) / 150m (STP)
Minimum Calibration
Length Over 100m recommended
Error Rate (BNC, RJ45) ±5% (After Calibration)
Compatible Connector
Type BNC, RJ45
Coaxial Cable Loop
Resistance 300 (Max)
Cable Map Display OLED (#1 – #8)
Others
Battery Type 3.7V Rechargeable lithium battery
900mAh
Recharge Port USB 2.0 Mini-B Type,
Over DC5V 600mA (USB charger)
Full Charge Time /
Continuous Use Time 2h 30m / RJ45 (3h), BNC (6h)
Temperature -10°C ~ +50°C
Humidity 0 ~ 80%
Case ABS UL94V-0
Dimensions 120 × 74 × 33 mm
Weight 210g
33mm
74mm
120mm

6
1. RJ-45: UTP cable connection port.
2. Power Input Input: Built-in battery
charging port. USB Cable (DC 5V/500 mA)
3. BNC: Coaxial cable connection port.
4. Display: 1.5 inch OLED
5. Power Button: Press for more than 2 sec.
to turn ON/OFF.
6. Direction Switch: Switch to set menu.
• To set menu, control with ▲▼ ,
direction switch
• To activate Enter Key, press the direction
switch.
7. Run Button: Button to measure cable.
• Used for cable measurement.
• When Green LED is on, press the switch to
start measurement
8. Charge Status LED
• Red – Charging
• Green – Charging done
2.0 Product Parts and Functions

7
3.0 Menu
3.1 Measure Menu
When power is on, Measure Menu is displayed as the initial menu screen. Select
the Type and Cable and press Run button for less than 3 seconds to display 1 time
measured value and save it to LIST. Press Run button for over 3 seconds to display
8 times measured value and save them to LIST.
The cable length of BNC and RJ45 is saved to LIST in Cable Length menu, and loop
resistance value is saved to LIST in Loop Resistance menu.
• 1 Type: Control direction key to select among BNC, RJ45 and Loop
Resistance Type
• Cable: Control direction key to select LOAD DATA of BNC, RJ45 Type Cable
• Menu: Press Enter key to move to sub sub-menu according to the selected Type
In ‘ 2 Cable ’ menu, ‘USER’ cannot be mo dified or deleted because it is a LOAD
DATA that the calibrated value is initialised.
1. BNC Type (Coaxial Cable) Setting and Measurement
Press Run (Green LED ON ) button to measure.
Cable Status: OPEN
Control direction key ▲▼ to set PAGE.

User Manual Coaxial and UTP Cable Tester
8
Cable Status: SHORT
Control direction key ▲▼ to set PAGE.
2. RJ45 Type ( UTP Cable) Setting and Measurement
Press Run (Green LED ON ) button to measure.
Cable Status: OPEN
Control direction key ▲▼ to set PAGE.
Cable Status: SHORT
Control direction key ▲▼ to set PAGE.

User Manual Coaxial and UTP Cable Tester
9
Loop Resistance: Measure Loop Resistance of Coaxial Cable
Press Run (Green LED ON) button to measure.
3.2 Type: Measurement Mode Type Setting (BNC, RJ45)
RJ45: Select UTP cable measurement mode
3.3 Cable Length: Cable Length and Status (Open, Short) Measurement
• START: In the menu, the Green LED lights up on Run button. To measure cable length,
press Run button.
• LOAD: From LOAD menu, press Enter Key to select the cable to measure Calibration in
Load Data. If you do not know the cable type, select USER.
• LOAD CANCEL: Delete the selected cable in LOAD menu.
• LIST: Press RUN button for less than 3 seconds to display 1 time measured value. Press
RUN button for over 3 seconds to display 8 times measured value. Press Enter key to
return to the previous menu.
• OPEN: Cable length is measured with nothing connected to the cable end. The cable is
not short-circuited.
• SHORT: Cable length is measured with nothing
connected to the cable end. The cable is short-
circuited.
When the product is connected with cable, the
measured value is displayed as OPEN, SHORT,
Cable open or Too short depending on the internal
condition of the product.
Measure Loop Resistance In case of cable Open

User Manual Coaxial and UTP Cable Tester
10
BNC Type (Coaxial Cable) Setting and Measurement
Select START and press Run (Green LED ON )
button to measure measure.
Cable OPEN
Control direction key ▲▼ to set PAGE
Cable SHORT
Control direction key ▲▼ to set PAGE
Select LOAD Select LOAD DATA Select START
Delete LOAD DATA
Altri manuali per CT10
1
Indice
Altri manuali Genie Tester per cavi