GEO Calibration 2000 SP Manuale utente

MODEL 2000 SP
GEO Calibration Inc.
2190 Smithtown Avenue
Ronkonkoma, NY 11779
USA
User Manual
English
Deutsch
Francais

2
STANDARD PACKAGE LISTING
• GEO Calibration Model 2000 SP Humidity Generator / Calibrator
• 1 Model 2000 SP desiccant cell lled with indicating molecular sieve (pre-installed)
• Power Cable
• Water Fill Syringe
• Capacitive Control Probe with calibration certicate
• Chamber Door (Per customer order)
• USB A to A cable
• USB Stick containing the following:
• GEO Model 2000 SP Product Manual
• GEO Software Manual
• GEO RH Automatic Ramp / Soak Software
• Model 2000 SP Drivers for Windows
Contents of the Standard Supply Package

3
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Each GEO Calibration product is warranted to be free from defects in material and workmanship under
normal use and service. The warranty period is one year and begins on the date of shipment. Parts,
product repairs, and services are warranted for 90 days. This warranty extends only to the original
buyer or end-user customer of a GEO Calibration authorized reseller, and does not apply to fuses, dis-
posable batteries, or to any product which, in GEO Calibration’s opinion, has been misused, altered,
neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling.
GEO Calibration does not warrant that software will be error free or operate without interruption.
GEO Calibration authorized resellers shall extend this warranty on new and unused products to end-us-
er customers only but have no authority to extend a greater or different warranty on behalf of GEO
Calibration. Warranty support is available only if product is registered at
https://www.geocalibration.com/register
and is purchased through a GEO Calibration authorized sales outlet or Buyer has paid the applicable
international price. GEO Calibration reserves the right to invoice Buyer for importation costs of repair/
replacement parts when product purchased in one country is submitted for repair in another country.
GEO Calibration’s warranty obligation is limited, at GEO Calibration’s option, to refund of the purchase
price, free of charge repair, or replacement of a defective product which is returned to a GEO Calibra-
tion authorized service center within the warranty period.
To obtain warranty service, contact your nearest GEO Calibration authorized service center to obtain
return authorization information, then send the product to that service center, with a description of the
difculty, postage and insurance prepaid (FOB Destination). GEO Calibration assumes no risk for dam-
age in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid
(FOB Destination). If GEO Calibration determines that failure was caused by neglect, misuse, con-
tamination, alteration, accident, or abnormal condition of operation or handling, including over voltage
failures caused by use outside the product’s specied rating, or normal wear and tear of mechanical
components, GEO Calibration will provide an estimate of repair costs and obtain authorization before
commencing the work. Following repair, the product will be returned to the Buyer transportation pre-
paid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WAR-
RANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. GEO CALIBRA-
TION SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion
or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may
not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or
other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability
of any other provision.
GEO Calibration Inc.
2190 Smithtown Avenue
Ronkonkoma, NY, 11779
U.S.A.
WARRANTY

4
INTRODUCTION
Thank you!
Thank you for purchasing the GEO Calibration Model 2000 SP humidity and temperature
generator/calibrator. We look forward to providing you the highest quality technical support as
you become familiar with your new humidity and temperature calibrator.
To better familiarize yourself with the Model 2000 SP, please take our product tour.
To get you calibrating right away, you can skip straight to our quick start guide.
Looking to go a bit deeper? Jump to see our calibration technical recommendations.
As you read through this product manual, please familiarize yourself with our warnings and
recommended best practices. By following the proper procedures, you will ensure your unit
performs to its highest potential.
WARNING As you read through this product manual, please familiarize yourself
with our recommended best practices. By following the proper
procedures, you will ensure your unit consistently performs to its
highest potential.
Once you have removed the Model 2000 SP from its external
packaging, please visually inspect the unit for damage. If damage is
found, please immediately contact your supplier.

5
PRODUCT OVERVIEW
Calibrator Applications
Once you have removed the Model 2000 SP from its external packaging, please visually inspect
the unit for damage. If damage is found, please immediately contact your supplier.
The GEO Model 2000 SP Humidity Calibrator generates and maintains a controlled humidity and
temperature environment for the purpose of testing or calibrating humidity and temperature
sensors, also known as hygrometers. The humidity calibration range is 5% up to 95%, while the
temperature range is from 5°C to 55°C.
The system’s accuracy is achieved via a NIST traceable internal control and reference probe.
The Model 2000 SP can calibrate many hygrometer types, including but not limited to:
• Probes
• Data-loggers
• Chart Recorders
• Additional Assorted Hygrometers
Before purchasing a Model 2000 SP, please review the dimensions of the calibration chamber to
ensure compatibility with the size requirements of any Hygrometers you intend to calibrate.

USB Cable
(A to A)
66
ITEM CHECK LIST
Listed below are standard contents included with the purchase of a new Model 2000 SP.
Humidity Generator Desiccant Canister
Control Probe
USB Stick
Fill Tube
Power Cable
Calibration Documents
GEO Calibration
Model 2000 SP
Pre-Filled with molecular sieve
HC2-S HygroClip
control probe (pre-installed
with calibration certicate)
Contains GEO Software
-
Chamber Door
With bung set
(Pre-Installed)

7
ACCESSORIES
Replacement
Desiccant
P/N: 3-DEC
System
Recalibration
P/N: RHG-A-CAL
Door Variations
Replacement
Fill Tube
P/N: RHG-A-FT
Replacement
Control Sensor
P/N: RHG-A-SCP
Silicone
Adapter Kits
P/N: RHG-A-BNG

8
UNIT DIAGRAM & PARTS LISTING
Below you will nd a diagram of the Model 2000 SP’s various operational parts.
FRONT
REAR
Status Indicator
Comm Indicator
Local Indicator
Fault Indicator
LCD Display
Desiccant
“NEXT”
“UP”
Button
Button
Button
Button“DOWN”
“EXIT”
Door Screw
Sample OUT
Probe Port
Water Fill Level
Sample IN
Fill Port
Cooling Fan
Carry Handle
Ground
12 V DC Power
Mains Power
Power Switch
Analog RH Out
USB Interface
Fuse
Drain Plug
Analog Temp out

9
Locate the Fill Port
The port is labeled and located on the middle lower
portion of the front panel.
Attach Fill Syringe to Fill Port
Press the ll syringe tip into the ll port, then rotate the
cap clockwise to secure.
3.
1.
Remove the Fill Cap
Rotate Counter-Clockwise to remove.
2.
QUICK START - FILLING RESERVOIR
Supplies Needed
Distilled Water Fill Syringe

10
QUICK START - FILLING RESERVOIR
- Pour distilled water into the elevated tube body.
- Take care not to insert any air into the reservoir.
- Monitor the water level indicator while lling.
5.
Loosen and Remove Syringe
Turn the ll syringe tip counter-clockwise to loosen.
6.
Re-Install the Fill Cap
Turn the cap clockwise to tighten the cap and seal the
ll port.
7.
Elevate and Fill Syringe
Altri manuali per 2000 SP
1
Indice
Altri manuali GEO Calibration Apparecchiature di prova
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione