Assembly Instructions M8124-EN
1. Proceed as follows in order to cool down the unit and empty
the mould (mould evacuation)
Display menu page Functions.
Select the function Cooling and activate with the key.
Select the function Mould evacuation and activate with the
key.
The activated function is indicated with the symbol.
2. Main switch off, remove the plug from the mains and empty
the unit.
Fig. 1 Flow-5, autonom. module
Fig. 2: Connection of light bulb (HL 1.x) to
8 pin cable plug.
3. Replace light bulb (HL 1.x)at measuring circuit x while
proceeding as follows:
Disconnect the cable plug from the socket (X 402.x)Fig. 1) at
the evaluation unit.
Disconnect screws (Label 1 Fig. 1) and remove cover.
Detach the light bulb (Fig. 1).
Open the 8 pin cable plug and replace the light bulb (HL 1.x)
with a new one (connect cable plug Fig. 2).
Close 8 pin cable plug and connect it to the socket
(X 402.x Fig. 1).
Connect new light bulb (HL 1.x Fig. 1).
Mount cover with screws (Label 1 Fig. 1).
4. Reconnect mains plug and switch on main switch.
5. Switch the unit on with the key.
6. Check unit functions.
7. Switch the unit off by press the key.
8. Main switch off.