1、Safety rules and precautions ................................................................................................................................. 3
2、Synopsis ................................................................................................................................................................ 4
3、Range and accuracy .............................................................................................................................................. 5
4、Technical specifications ........................................................................................................................................ 5
5、Instrument structure ............................................................................................................................................. 8
6、Operational approach ........................................................................................................................................... 9
6.1、Startup & Shutdown ...................................................................................................................................... 9
6.2、Interface is introduced ................................................................................................................................... 9
6.2.1、Main Interface ......................................................................................................................................... 9
6.2.2、Set interface ............................................................................................................................................ 9
6.2.3、Resistance test interface ....................................................................................................................... 10
6.2.4、Reading interface .................................................................................................................................. 10
6.2.5、Product information interface .............................................................................................................. 10
6.3、Icon shows ................................................................................................................................................... 11
6.4、Battery check ............................................................................................................................................... 11
6.5、Resistance test ............................................................................................................................................. 12
6.5.1、Connection method .............................................................................................................................. 12
6.5.2、The test operation ................................................................................................................................ 12
6.6、Backlight control .......................................................................................................................................... 13
6.7、Data is stored ............................................................................................................................................... 14
6.8、Data access/deletion .................................................................................................................................... 14
6.9、Product information consulting ................................................................................................................... 15
6.10、Overload protection ................................................................................................................................... 15
6.11、Test the stop time Settings ........................................................................................................................ 15
7、Packing list .......................................................................................................................................................... 16

- 3 -
1
、
Safety rules and precautions
Thank you for purchasing our Handheld DC resistance tester. In order to avoid
possible electric shock or personal injury before your first use of this tester, please be
sure to read and strictly observe the safety rules and precautions set out in this manual.
Special attention should be paid to safety when using this instrument under any
circumstances.
² This instrument according to IEC61010 safety specifications for design,
production, inspection.
² Special attention should be paid to safety when using this instrument under any
circumstances.
² When measuring, please do not use the high frequency signal generator such as
mobile phone near the instrument, so as not to cause error.
² Pay attention to the label and symbol of the instrument body.
² Before use, make sure that the instrument and accessories are in good condition and
the instrument and test line insulation layer are not damaged, exposed or broken before
use.
² During the measurement, do not contact the bare conductor and the circuit being
measured.
² Make sure the connector plugs of the wires are tightly inserted into the instrument
interface.
² Do not measure in inflammable place, spark may cause explosion.
² When the instrument is in use, the casing or test line is broken and the metal is
exposed, please stop using it.
² Do not place or store the instrument in hot, humid, dewy places or under direct
sunlight for a long time.

- 4 -
² When replacing the battery of the meter, please confirm that the test line has been
removed from the meter and the meter is in shutdown state.
² Instrument display battery low voltage symbol " ", should replace the battery in
time, otherwise it will cause error.
² Do not measure when the battery cover is open or when it thunders.
² Pay attention to the measuring range and operating environment specified in this
instrument.
² The use, disassembly, calibration and maintenance of this instrument must be
operated by authorized personnel.
² If the instrument is in danger due to its continued use, it shall be stopped
immediately and sealed up for immediate disposal by an authorized agency.
² The instrument and the " " safety warning sign in the manual, the user must
strictly follow the contents of this manual for safe operation.
2
、
Introduction
Handheld DC resistance tester, also known as transformer DC resistance tester, DC
resistance rapid tester, grounding conductivity tester, adopts microprocessor technology,
four-wire test, safe, precise and reliable.Is mainly used for measurement of transformer
winding resistance, transformer winding resistance, ground down lead conduction testing,
the wire resistance of the cable, switch, socket, relay contact resistance, winding, motor,
shell and equipment, lightning protection zone, ground beam, structure, rack, steel, pipe,
Windows, fence, radiator, pipeline connection between objects such as metal
components resistance test.It is widely used in telecommunication, electric power,
meteorology, machine room, oil field, electric power distribution line, tower transmission

- 5 -
line, gas station, factory grounding grid, lightning rod and so on.
Handheld DC resistance tester is composed of a host, monitoring software, test line
and communication line.Host handheld portable design is convenient for field application,
with charging function without on-site power search, full-color large LCD display, clear at
a glance, easy to use touch screen operation, port overload protection function.Large
capacity storage 500 groups of data, resistance measurement range: 10.0 u Ω 50.00 K Ω,
measuring accuracy: ±0.2%FS±10dgt.The upper computer software has the functions of
reading, consulting, saving and reporting historical data.
3
、
Range and accuracy
4
、
Technical specifications
Function
Is mainly used for measurement of transformer dc resistance,
transformer winding resistance, network connectivity, cable
conductor resistance, contact resistance of switches,
connectors, relays, winding, motor, transformer winding
Measuring
current
Range
Precision
Resolution
10A
10.0uΩ~1000.0uΩ
±0.2%FS±10dgt
0.1uΩ
1.00mΩ~100.00mΩ
±0.2%FS±10dgt
0.01mΩ
5A
100.0mΩ~1000.0mΩ
±0.2%FS±10dgt
0.1mΩ
1A
1.000Ω~10.000Ω
±0.2%FS±10dgt
0.001Ω
0.1A
10.00Ω~100.00Ω
±0.2%FS±10dgt
0.01Ω
10mA
100.0Ω~1000.0Ω
±0.2%FS±10dgt
0.1Ω
1mA
1.000KΩ~10.000KΩ
±0.2%FS±10dgt
0.001KΩ
10.00KΩ~50.00KΩ
±0.2%FS±20dgt
0.01KΩ
Note: the standard condition of error range in the above table is 25℃±5℃, and the maximum error
in the working environment is 0.5%FS±10dgt.

- 6 -
resistance and metal riveting resistance, metal component
coupling between resistance test, low resistance testing,
contact resistance testing, etc.
Resistance range
10.0uΩ-50.00KΩ
Resolution ratio
0.1 uΩ
Precision
±0.2%FS±10dgt
Detection
method
The four-wire test
Measuring
current
10A、5A、1A、0.1A、10mA、1mA
Maximum short
circuit current
10A
overload
protection
Yes
Self discharge
Yes
Power
DC12.6v 2500mAh large-capacity lithium battery
Charging
function
Yes
Back light
Yes, suitable for dark places
Display mode
LCD Full-color display
Overflow shows
The "OL" symbol is displayed when the overrange overflow
occurs
Touch screen
operation
Yes

- 7 -
The LCD size
Length and width: 108mm×65mm
Size of
instrument
Length, width and height: 240mm×188mm×85mm
The test line
length
5 meters, 1 red, 1 black
USB interface
With USB interface
Line of
communication
1 USB communication cable
Data storage
500 groups
View Data
Data access function
Cell voltage
The battery power is displayed in real time, indicating that the
battery should be charged in time when the battery voltage is
low
Auto power-off
Turn off the meter after no operation for about 15 minutes
Power
dissipation
Standby: approx. 116mA (20% brightness)
Measurement: 27W Max
Weight
Instrument: 1100g(including batteries)
Test line: 850g
Operating
temperature and
humidity
- 10℃~40℃,Below 70%rh
Storage
temperature and
humidity
-20℃~60℃,Below 70%rh

- 8 -
Insulation
resistance
More than 10 m Ω (circuit between the shell and 500 V)
Withstand
voltage
AC 3700V/ RMS (between circuit and housing)
Electromagnetic
property
IEC61010-4-3, wireless frequency electromagnetic field ≤1V/m
Suitable for
safety
IEC61010-1、CAT Ⅲ 600V、Pollution level 2、JJG724-1991
<<VERIFICATION Regulation of DC Digital Ohmmeter>>,
JJG166-1993 <<Verification Regulation of DC Resistor>>,
<<VERIFICATION Regulation of DL/T967-2005 Circuit
Resistance Tester and DC Resistance Rapid Tester>>
5
、
Instrument structure
1. LCD 2. Power 3. P-wire
4.USB 5.C1 6.P1
7. P2 8. C2 9. Charging mouth

- 9 -
6
、
Operational approach
6.1
、
Startup & Shutdown
Press the "Power" button to start the machine, and press the "Power" button to
shut down the machine.
6.2
、
Interface is introduced
6.2.1
、
Main Interface
6.2.2
、
Set interface
Indice
Altri manuali HTC Apparecchiature di prova
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione