Hunter 45013-01 Manuale di istruzioni

Type 2 ModelsType 2 ModelsType 2 Models
Form# 45013-01
20100128
©2010 Hunter Fan Co.
For Your Records and
Warranty Assistance
For reference, also attach your receipt or a copy
of your receipt to the manual.
__________________________________________
Model Name
__________________________________________
Model No.
__________________________________________
Date Purchased
__________________________________________
Where Purchased
English Español
Owner’s Guide and Installation Manual

2
45013-01 • 01/28/10 • Hunter Fan Company
© 2010 Hunter Fan Company
Your new Hunter® ceiling fan is an addition to your home or oce that
will provide comfort and performance for many years. is installation
and operation manual gives you complete instructions for installing
and operating your fan.
We are proud of our work. We appreciate the opportunity to supply
you with the best ceiling fan available anywhere in the world.
Before installing your fan, for your records and warranty assistance,
record information from the carton and Hunter nameplate label
(located on the top of the fan motor housing).
Cautions and Warnings
•READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING
INSTALLATION. SAVE THESE INSTRUCTIONS.
• Use only Hunter replacement parts.
• To reduce the risk of personal injury, attach the fan directly to the
support structure of the building according to these instructions,
and use only the hardware supplied.
• To avoid possible electrical shock, before installing your fan,
disconnect the power by turning o the circuit breakers to the
outlet box and associated wall switch location. If you cannot lock
the circuit breakers in the o position, securely fasten a prominent
warning device, such as a tag, to the service panel.
• All wiring must be in accordance with national and local electrical
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a
qualied electrician.
• To reduce the risk of personal injury, do not bend the blade
attachment system when installing, balancing, or cleaning the fan.
Never insert foreign objects between rotating fan blades.
• To reduce the risk of re, electrical shock, or motor damage, do not
use a solid-state speed control with this fan. Use only Hunter speed
controls.
Welcome
Table Of Contents
1 • Getting Ready......................4
2 • Installing the Hanger Bracket . . . . . . . 5
3 • Assembling and Hanging the Fan . . . 6
4 •Wiring the Fan......................7
5 • Installing the Canopy and Canopy
Trim Ring.........................8
6 • Assembling the Blades . . . . . . . . . . . . . 9
7 • Completing Your Installation With
or Without a Bowl Light
Fixture . . . . . . . . . . . . . . . . . . . . . . . . . . .10
8 • Operating and Cleaning Your Ceiling
Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
9 • Troubleshooting . . . . . . . . . . . . . . . . . . 15

3
45013-01 • 01/28/10 • Hunter Fan Company
Installer’s Choice and Optional Accessories
Understanding Mounting and Installer’s Choice®
Hunter’s patented 2-position mounting system provides you maximum
installation exibility and ease. You can install your Hunter fan in one
of two ways, depending on ceiling height and your preference: Standard
or Angled mounting. e steps in this manual include instructions for
both Installer’s Choice mounting methods.
Considering Optional Accessories
Consider using Hunter’s optional accessories, including a wall-mounted
or remote speed control. To install and use the accessories, follow
the instructions included with each product. For quiet and optimum
performance of your Hunter fan, use only Hunter speed controls.
For ceilings higher than 8 feet, you can purchase
Hunter extension downrods. All Hunter fans use
sturdy 3/4” diameter pipe to assure stability and
wobble-free performance.
Standard Mounting hangs from the
ceiling by a downrod (included).
Angled Mounting recommended for a
vaulted or angled ceiling
Support Brace
Standard
Mounting
Style
Ceiling
Outlet Box
Support Brace
Ceiling
Outlet Box
Angled
Mounting
Style
8
12
CAUTION: To reduce the risk of personal
injury, attach the fan directly to the support
structure of the building according to these
instructions, and use only the hardware
supplied.

4
45013-01 • 01/28/10 • Hunter Fan Company
To install a ceiling fan, be sure you can do the following:
• Locate the ceiling joist or other suitable support in ceiling.
• Drill holes for and install wood screws.
• Identify and connect electrical wires.
• Lift 40 pounds.
If you need help installing the fan, your Hunter fan dealer can direct
you to a licensed installer or electrician.
Gathering the Tools
You will need the following tools for installing the fan:
• Electric drill with 9/64” bit
• Standard screwdriver (magnetic tip recommended)
• Phillips-head screwdriver (magnetic tip recommended)
• Wrench or pliers
• Ladder (height dependent upon installation site)
Checking Your Fan Parts
Carefully unpack your fan to avoid damage to the fan parts. Refer to
the included Parts Guide. Check for any shipping damage to the motor
or fan blades. If any parts are missing or damaged, contact your Hunter
dealer or call Hunter Technical Support Department at 888-830-1326.
Preparing the Fan Site
Before you begin installing the fan, follow all the instructions in
the pullout sheet called “Preparing the Fan Site.” Proper ceiling fan
location and attachment to the building structure are essential for
safety, reliable operation, maximum eciency, and energy savings.
Installing Multiple Fans?
If you are installing more than
one fan, keep the fan blades and
blade irons (if applicable) in sets,
as they were shipped.
1 • Getting Ready

5
45013-01 • 01/28/10 • Hunter Fan Company
2-1. Drill two pilot holes into the wood support structure through the
outermost holes in the outlet box. e pilot holes should be 9/64”
in diameter.
Note: Your fan comes with four pre-installed mounting isolators.
2-2. read the lead wires from the outlet box down through the hole
in the middle of the hanger bracket.
2-3. Align the slotted holes in the hanger bracket with the pilot holes
you drilled in the wood support structure. For proper alignment
use slotted holes directly across from each other. If you are
installing the fan on an ANGLED ceiling, be sure to orient the
hanger bracket as shown in Illustration 2-3 (left or right view).
Note: e isolators should be ush against the ceiling.
2-4. Place a at washer on each of the two 3” screws and pass the
screws through the slotted holes in the hanger bracket into the
pilot holes you drilled.
Tighten the screws into the 9/64” pilot holes; do not use lubricants
on the screws. Do not over tighten.
Flat Washer
3” Screw
Steps 2-2 – 2-4
Hanger
Bracket
Isolator
Step 2-3 (Angled Ceiling Only)
OR
Ceiling Peak Ceiling Peak
Large
Opening Large
Opening
LEFT RIGHT
2 • Installing the Hanger Bracket

6
45013-01 • 01/28/10 • Hunter Fan Company
You can assemble your fan for standard or angled mounting as shown
in steps 3-1 – 3-3.
3-1. To assemble fan to hang down from a at or angled ceiling, place
the canopy and canopy trim ring around the adapter so that they
rest on the fan assembly.
3-2. Feed the wires from the fan through the downrod.
Note: Make sure all the wires are on the same side of the metal
dowel pin inside the dowrod.
3-3. Loosen the square head set screw on the adapter to install the
pipe and ball assembly. Note: When the pipe and ball assembly
is fully installed, 2-3 threads on the pipe will still be visible; this is
normal. Securely retighten the set screw with a wrench or pliers.
CAUTION: e adapter has a special coating on the threads. Do
not remove this coating; the coating prevents the downrod from
unscrewing. Once assembled, do not remove the downrod.
WARNING: Do not carry or lift fan by canopy.
3-4. Raise the fan and place the ball into the hanger bracket.
3-5. Align the notch on the ball with the indent in the hanger bracket.
(Rotate the fan until you hear the notch pop into place.)
Go to 4 • Wiring the Fan.
WARNING: Fan may fall if not assembled as directed in these
installation instructions.
Steps 3-4 – 3-5
Indent
Steps 3-1 – 3-3
Downrod
Canopy
Canopy
Trim
Ring
Set Screw
Adapter
3 • Assembling and Hanging the Fan

7
45013-01 • 01/28/10 • Hunter Fan Company
All wiring must be in accordance with national and local electrical
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a
qualified electrician.
Wall switches are not included. Select an acceptable general-use switch
in accordance with national and local electrical codes.
4-1. Before attempting installation, make sure the power is still o.
4-2. To connect the wires, hold the bare metal leads together and place
a wire connector over them, then twist clockwise until tight. For
all these connections use the wire connectors provided.
4-3. Connect the bare or green ground wire (grounded) from the
ceiling to the green ground wire (grounded) from the ceiling plate
and the green ground wire from the fan.
4-4. Connect the white wire (ungrounded) from the ceiling to the
white wire (ungrounded) from the fan.
4-5. Connect the remaining wires as follows:
Dual Switch Wiring:
• e black wire (ungrounded) from the ceiling to the black wire
(ungrounded) from the fan
• e black/white wire (ungrounded) from the fan to the wire
(ungrounded) for the wall switch
Single Switch Wiring:
• e black wire (ungrounded) from the ceiling to the black
(ungrounded) and the black/white wire (ungrounded) from
the fan
CAUTION: Be sure no bare wire or wire strands are visible after
making connections.
4-6. Turn the wire connectors upward and push them carefully back
through the ceiling plate into the outlet box.
4-7. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the
outlet box.
Wire
Connector
4 •Wiring the Fan

8
45013-01 • 01/28/10 • Hunter Fan Company
5-1. Partially install two canopy screws (about 2 full turns) in the
hanger bracket.
5-2. Raise the canopy over the hanger bracket. Align partially installed
screws with key slots in canopy.
5-3. Twist canopy clockwise to secure.
5-4. Install third & fourth canopy screw in round hole on canopy.
Securely tighten all four screws.
5-5. Using both hands, push the canopy trim ring up to the top of the
canopy.
5-6. Twist canopy trim ring clockwise to secure the canopy.
Should you need to remove the canopy
trim ring, follow these steps:
1. Twist canopy trim ring counter
clockwise until it releases from
canopy.
Steps 5-1 – 5-2
Canopy Trim
Ring
Canopy
Hanger Bracket
Step 5-3
Canopy
Screw
Step 5-4
Step 5-5
5 • Installing the Canopy and Canopy Trim Ring

9
45013-01 • 01/28/10 • Hunter Fan Company
Steps 6-2 – 6-4
Hunter fans use several styles of fan blade irons (brackets that hold the
blade to the fan).
6-1. Install the grommets into the blades by hand.
6-2. Place each blade between a blade iron and medallion. Install three
blade screws to attach the medallion to the blade iron. Repeat for
all blades.
6-3. For each blade, insert one blade mounting screw through the
blade iron, and attach lightly to the fan. Insert the second blade
mounting screw, then securely tighten both mounting screws.
Blade Assembly
Screws
Use with grommet
Use without grommet
Blade
Mounting
Screw
Grommet
6 • Assembling the Blades
Step 6-1 (Detail)

10
45013-01 • 01/28/10 • Hunter Fan Company
Your Hunter fan comes with an integrated light xture assembly and
an optional switch housing cap and plug button. is feature gives
you the option of installing the fan with OR without the included light
xture. e steps below direct you whether or not you are installing a
light xture.
WARNING: Use only the light xture supplied with this fan model.
7-1. To attach the lower motor housing, partially install two housing
assembly screws into the switch housing mounting plate.
7-2. Feed the upper plug connector through the center opening of the
housing.
7-3. Align the keyhole slots in the housing with the housing assembly
screws.
7-4. Turn the housing counterclockwise until the housing assembly
screws are rmly situated in the narrow end of the keyhole slots.
Install the remaining screw into the housing. Tighten all three
screws rmly.
CAUTION: Make sure the upper switch housing is securely
attached to the switch housing mounting plate. Failure to properly
attach and tighten all three assembly screws could result in the
switch housing and light xture falling.
7-5. If you want to install the light xture, proceed with step 7-6
now.
If you do not want to install the light xture, you need to
uninstall it now. See “Uninstalling the Light Fixture” in Step 7-17.
Once you have uninstalled the light xture, continue with Step
7-6.
Steps 7-1 – 7-3
Housing
Assembly
Screw
Housing
Assembly
Screw
Lower
Motor
Housing
Switch Housing
Mounting Plate
7 • Completing Your Installation With or Without a Bowl Light Fixture
Indice
Altri manuali Hunter Fan

Hunter
Hunter 20801 Manuale

Hunter
Hunter 20406 Manuale

Hunter
Hunter 51734 Manuale utente

Hunter
Hunter 42600-01 Manuale di istruzioni

Hunter
Hunter 27196 Manuale utente

Hunter
Hunter 21331 Manuale

Hunter
Hunter 28688 Manuale

Hunter
Hunter 22388 Manuale

Hunter
Hunter 23958 Manuale

Hunter
Hunter M3633-01 Manuale utente

Hunter
Hunter 42798-01 Manuale utente

Hunter
Hunter Millennium/Metro 9103x Manuale utente

Hunter
Hunter 28839 Manuale di istruzioni

Hunter
Hunter 23949 Manuale di servizio

Hunter
Hunter 21894 Manuale

Hunter
Hunter Wingate Manuale utente

Hunter
Hunter 90220 Manuale utente

Hunter
Hunter 20179 Manuale

Hunter
Hunter 28482 Manuale

Hunter
Hunter 21620 Manuale