iLiving ILG001TH Manuale utente

1
Humidity / Thermostat control box
for Attic Gable Ventilator
MODEL: ILG001TH MODEL: ILG002T
120VAC, 60Hz
Owner’s Manual
PLEASE READ AND
SAVE THESE INSTRUCTIONS

2
TABLE OF CONTENTS
Important Instructions……………………………………. 3
Installing Instructions……………………….………..…… 6
Operating Instructions……………………….………....… 8
Maintenance and Cleaning………………………………. 8
Troubleshooting…………………………………………… 9

3
IMPORTANT INSTRUCTIONS
CAUTION: Please read and save these instructions. Read carefully
before attempting to assemble, install, operate or maintain the
product described. Do not use the control box if any part is damaged
or missing.
Protect yourself and others by observing all safety information. Failure
to comply with instructions could result in personal injury and/or
property damage!
Retain instructions for future reference.
General Safety Information
NOTE: To comply with UL507, air circulator is not to be used in
unattended areas.
1. Ensure that the power source conforms to the electrical
requirements of the fan. All wiring must be in accordance with
National Electrical Code (ANSI/NFPA 70-1999).
2. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
3. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag to the service panel.
4. Installation work and electrical wiring must be done by a qualified
person in accordance with appliance codes and standards, including
fire-rated construction codes and standards.

4
5. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent excessive low pressure and to prevent back drafting. Follow
the heating equipment to guidelines and safety standards such as
those published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. The wiring must be permanent. DO NOT USE EXTENSION CORD!
Although the Powered Gable Ventilator may be wired directly to
power, we advise that some type of shut off switch be installed on
the line. Please see the section on electrical wiring for suggested
wiring diagrams and instructions.
8. For general ventilating use only. Do not use this fan to exhaust
hazardous or explosive materials or vapors.
9. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
10. Ensure that the power source conforms to the electrical
requirements of the fan.
11. Always disconnect power before inspection or cleaning, as motor
may restart unexpectedly.
12. In cases in which property damage may result from malfunction of
the fan, a suitable alarm (air switch, temperature sensor, etc.)
should be used.

5
WARNING: Do not depend on any switch as the sole means of
disconnecting power when installing or servicing the fan. Failure to do
so may result in fatal electrical shock.
WARNING: Do not insert fingers or foreign objects into the fan. Do not
block or tamper with the fan in any manner while it is in operation.
WARNING: Unplug prior to servicing unit.
SAVE THESE INSTRUCTIONS

6
INSTALLATION INSTRUCTION
WARNING: Turn off the wall switch prior to servicing the unit. To avoid
personal injury, wall switch must be turned off before servicing since
the built-in thermal protection may turn on the circulator
automatically.
1. Mount the control box on the adjacent rafter.
2. Connect the Black and White wire line out from the control box to
the electric lines controlled by a master On /Off switch as shown
below wiring diagram.

7
Wiring Diagram for ILG001TH

8
Wiring Diagram for ILG002T

9
OPERATION INSTRUCTION
Please set the Thermostat or Humidistat to desired condition before
operating the fan. Use a screw driver to turn the arrow of the knob to
the desire temperature and humidity mark on the panel of the control
box. To avoid the possibility of overturning the fan, operate on a
stable, level surface. Do not move fan while it is in operation.
Product Specifications
MAINTENANCE AND CLEANING
WARNING: Parts replacement and troubleshooting to be performed
only by qualified personnel.
WARNING: Do not depend on any switch as the sole means of
disconnecting power when installing or servicing the fan. Failure to do
so may result in fatal electrical shock.
WARNING: Turn off the wall switch before servicing or cleaning.
Model
Voltage
Current
Temperature
Control Range
ILG001TH
120V 60Hz
Max 10A
60ºF – 120ºF
ILG002T
120V 60Hz
Max 10A
60ºF – 120ºF

10
CAUTION: There is no user maintenance part except regular cleaning
as indicated below. All other servicing or maintenance should be
performed by qualified service personnel.
To clean the control box, use a soft damp cloth. Wipe down with a dry
cloth.
Do not use cleaners that are harmful to paints or plastics.
CAUTION: Do not use gasoline, benzene, thinner, harsh cleaners, etc.,
which are dangerous and will damage the air circulator.
TROUBLESHOOTING
If your fan fails to operate, please follow these Instructions:
1. Make sure the fan is well connected and the electrical line-in is
working properly.
2. Check for any obstruction. If you find an obstruction, turn the fan
“OFF”. Disconnect the fan and carefully remove the obstruction.
Reconnect the fan and turn it on again and see if it resumes normal
operation.
NOTE: IF YOU EXPERIENCE A PROBLEM WITH YOUR FAN, PLEASE DO
NOT ATTEMP TO OPEN OR REPAIR THE FAN YOURSELF. DOING SO
COULD CAUSE DAMAGE OR PERSONAL INJURY. Always consult the
authorized dealer or certified electrician for further action.
Questo manuale è adatto per i seguenti modelli
1
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente