Intec ARGUS 300 Manuale utente

ARGUS
ARGUS Copper Test Manual 1
ARGUS
Copper Test Manual
Version: 1.90 / EN
for ARGUS 300 and ARGUS 260
Important note:
Depending on the range of functions supplied, various menu options or functions may be
hidden.

ARGUS
2ARGUS Copper Test Manual
© by intec Gesellschaft für Informationstechnik mbH
D-58507 Lüdenscheid, Germany, 02/2022
All rights, including translation rights, reserved. No part of this work may be reproduced,
duplicated or disseminated in any form (print, photocopy, microfilm or any other method)
without written consent.
All rights are reserved. No one is permitted to reproduce or duplicate, in any form, the
whole or part of this document without intec´s permission.

ARGUS
ARGUS Copper Test Manual 3
1Introduction .........................................................................................4
2Safety information copper tests ........................................................6
3Copper tests ......................................................................................11
3.1 Copper tests multimeter ..................................................................11
3.1.1 Auto test .....................................................................................11
3.1.2 Voltage measurement (U= and U~) ...........................................13
3.1.3 Capacitive symmetry measurement (CSym) .............................15
3.1.4 Capacitance measurement (C) ..................................................18
3.1.5 Isolation resistance measurement (Iso.) ....................................22
3.1.6 Resistance symmetry (RSym) ..................................................24
3.1.7 Resistive fault location (RFL) .....................................................30
3.1.8 Loop resistance measurement (R) ............................................32
3.1.9 DC current measurement (I=) ....................................................34
3.1.10 Longitudinal conversion loss (LCL) ..........................................36
3.1.11 Near-end crosstalk (NEXT) ......................................................38
3.1.12 Signature detection/termination detection ...............................40
3.1.13 Fast cable check ......................................................................42
3.1.14 Remote kit control (Rem.) ........................................................44
3.2 Copper tests Oscilloscope ..............................................................46
3.2.1 Line Scope .................................................................................46
3.2.2 Graph functions .........................................................................48
3.3 TDR ....................................................................................................51
3.3.1 Graph functions .........................................................................53
3.3.2 Examples ...................................................................................56
4Appendix ...........................................................................................59
A) Hotkeys ..............................................................................................59
B) Software Licenses .............................................................................60
C) Abbreviations .....................................................................................61
D) Index ..................................................................................................64

1 Introduction
4 ARGUS Copper Test Manual
1 Introduction
ARGUS Copper tests
The copper tests for ARGUS 300 and ARGUS 260 enable you to detect dangerous
voltages and currents early on and reliably assess the physical quality of the line –
particularly when DSL synchronisation is not possible or the data rate is low due to
asymmetry, interference sources or other mechanical line problems.
Technical features of the ARGUS copper tests at a glance:
Copper tests Multimeter
- Multiple, preconfigured measurement profiles can be executed as an auto test.
-Voltage measurement enables measurement of the supply voltage, as well as
external voltages caused e.g. by contact between two wires or isolation faults.
- With the aid of capacitive symmetry measurement, it is possible to detect asymmetry
in the subscriber line that can result in signal distortions or transmission errors.
-Capacitance measurement detects interruptions as well as typical input capacitances
of connected devices and enables estimation of line lengths.
-Isolation resistance measurement reveals damage to cable isolation, moisture
penetration or oxidised contact points.
- With the aid of resistance symmetry measurement, it is possible to detect irregula-
rities in the subscriber line that can result in signal distortions or transmission errors.
-Resistive fault location (RFL) can display resistance to fault (Rx), distance to fault,
resistance from fault to short circuit (Ry), loop resistance (Rs), line length, and fault
resistance (Rfault).
-Loop resistance measurement aids detection of short circuits and estimation of line
lengths.
-DC current measurement can be used to detect emergency, external and normal
power feeds as well as breaks in the line.
-Unbalance measurement (LCL): This measurement uses a frequency of 1 MHz to
measure asymmetry in a line pair.
-NEXT measurement: Measurement of near-end crosstalk at a frequency of 1 MHz.
-Signature detection is used to detect the signatures and test terminations (PPAs)
connected to the subscriber line.
- The fast cable check verifies the correctness of a three-pole (Tip/Ring/Ground)
connection.
- The integrated remote kit control lets you remotely set the line end to the desired
state either manually or automatically using a variety of electronic instrument kits.
Copper tests Oscilloscope
-Line Scope: High-performance realtime Line Scope with display in time and frequency
range (FFT) up to 35 MHz
-TDR: Time domain reflectometer to measure line lengths and locate faults

1 Introduction
ARGUS Copper Test Manual 5
Note:
You can download the latest manuals at http://www.argus.info/service/downloads
or simply contact one of our service representatives:
intec Gesellschaft für Informationstechnik mbH
Rahmedestr. 90
D-58507 Lüdenscheid
Tel.: +49 (0) 2351 / 9070-0
Fax: +49 (0) 2351 / 9070-70
www.argus.info/en

2 Safety information copper tests
6 ARGUS Copper Test Manual
2 Safety information copper tests
There are the following safety specifications:
VDC 0 V to 200 V
VAC 0 V to 200 V
IDC 0 mA to 150 mA
ISO 105 VDC, max. 2 mA
R13 VDC, max. 15 mA
The following special instructions must be observed for the individual measurements:
Voltage
Be sure to observe the permissible measuring range specified above when measuring
voltage.
Capacitance/capacitive symmetry
Before measuring, make sure that the voltage thresholds given in the table below are not
exceeded during the measurement. Certain measurements can require a longer settling
time. An automatic “TRG-opt.” measurement can thus take some time.
Isolation resistance
Before measuring, make sure that the voltage thresholds given in the table below are not
exceeded during the measurement. During the measurement, the ARGUS can apply a
measuring voltage of up to 105 V max. 1 mA) to the line. Certain measurements can
require a longer settling time. An autotest can thus take some time.
Loop resistance/resistance symmetry
Before measuring, make sure that the voltage thresholds given in the table below are not
exceeded during the measurement. During the measurement, the ARGUS can apply a
measuring voltage of up ton 13 V (max. 15 mA) to the line.
DC current
Be sure to observe the permissible measuring range specified above when measuring DC
current. Make sure you connect the ARGUS in the circuit in series.

2 Safety information copper tests
ARGUS Copper Test Manual 7
Longitudinal conversion loss (LCL)/NEXT
Before measuring, make sure that the voltage thresholds given in the table below are not
exceeded during the measurement. When measuring LCL or NEXT using the ARGUS,
any type of additional measurement lead can falsify the measurement. Both the length
and the position of the measurement leads with respect to each other can influence the
measurement result significantly.
Signature detection/fast cable check/remote kit control
Before measuring, make sure that the voltage thresholds given in the table below are not
exceeded during the measurement.
Voltage thresholds
Measurement UDC (V) to UAC (Veff) to
R* 3,5 30
R-Sym* 30 30
ISO-R* 5 30
C* 17 17
C-Sym* 17 17
LCL 10 7
NEXT 10 7
Signature 3 3
Fast cable check** 5 30
Remote Box 3 3
* Measured on 200 kΩ load
** Loop limit value 10 kΩ

2 Safety information copper tests
8 ARGUS Copper Test Manual
Measuring accuracies copper tests:
Voltage:
DC voltage measurement (U=):
Measuring range: Resolution: Accuracy:
0 V - 9.99 V 0.01 V ±(0.5 % + 2 digits)
10 V - 200 V 0.1 V ±(0.5 % + 2 digits)
AC voltage measurement (sine, 50 Hz) (U~):
Measuring range: Resolution: Accuracy:
0 V - 9.99 V 0.01 V ±(2 % + 2 digits)
10 V - 200 V 0.1 V ±(1.5 % + 2 digits)
Frequency: 10 Hz to 200 Hz; 0.2 Hz; ±(1.5 % + 2 digits); sine
When measuring voltages, the input resistance depends on the measuring range:
- Measuring range 1: 0 V - 25 V; Input resistance: 1.694 MΩ
- Measuring range 2: 25 V - 200 V; Input resistance: 1.05 MΩ
As soon as the total of all voltages exceeds 25 V, the measurement is switched over.
Capacitive symmetry measurement (CSym):
Measuring range: Resolution: Accuracy of capacity diffe-
rence:
10 nF - 4 µF 0.01 nF 0.1% of the capacity to
ground
Capacitive measurement, measuring frequency 8 Hz (C):
Measuring range: Resolution: Accuracy:
0.01 nF - 9.99 nF 0.01 nF ±(4 % + 4 digits)
10 nF - 99.99 nF 0.01 nF ±(4 % + 4 digits)
100 nF - 999.9 nF 0.1 nF ±(3 % + 1 digit)
1 μF - 8 μF 1 nF ±(3 % + 1 digit)
* All specifications relate to a comparison measurement using film capacitors.

2 Safety information copper tests
ARGUS Copper Test Manual 9
Isolation resistance measurement with 105 V, max. 2 mA (Iso.):
Measuring range: Resolution: Accuracy:
0.1 kΩ - 99.9 Ω0.1 kΩ±(2 % + 1 digit)
100 kΩ - 999 kΩ1 kΩ±(2 % + 1 digit)
1 MΩ - 9.99 MΩ10 kΩ±(2 % + 1 digit)
10 MΩ - 99.9 MΩ100 kΩ±(5 % + 1 digit)
100 MΩ - 1 GΩ100 kΩ±(5 % + 1 digit)
Isolation resistance measurement with 8 V, max. 8 mA (Iso.):
Measuring range: Resolution: Accuracy:
0.1 kΩ - 99.9 kΩ0.1 kΩ±(2 % + 1 digit)
100 kΩ - 999.0 kΩ1 kΩ±(2 % + 1 digit)
1 MΩ - 9.99 MΩ10 kΩ±(2 % + 1 digit)
10 MΩ - 40 MΩ100 kΩ±(5 % + 1 digit)
Resistance difference (RSym):
Measuring range: Resolution: Accuracy:
10 Ω - 5 kΩ0.1 Ω± 0.2 % of RLoop ± 0.2 Ω
Resistive fault location (RFL):
Display of: Measuring ranges: Accuracy Rx at Lx/L = 0.1
Resistance to fault (Rx),
distance to fault
Loop resistance (Rs):
10..9999 Ω
Rs = 2000 Ω: ± 0.3 %
± 0.05 Ω
Resistance from fault to
short circuit (Ry)
Fault resistance (Rfault):
0..20 MΩ
Rs = 200 Ω: ± 1.0 % ± 0.06 Ω
Loop resistance (Rs),
line length
Fault resistance(Rfault)

2 Safety information copper tests
10 ARGUS Copper Test Manual
Loop resistance measurement with 13 V, max. 15 mA (Iso.):
Measuring range: Resolution: Accuracy:
1 Ω - 999.9 Ω0.1 Ω±(1 % + 3 digits)
1 kΩ - 9.999 kΩ1Ω ±(1 % + 1 digit)
10 kΩ - 99.99 kΩ10 Ω±(1 % + 1 digit)
100 kΩ - 999.9 kΩ100 Ω±(1 % + 1 digit)
1 MΩ - 9.999 MΩ1 kΩ±(2 % + 1 digit)
10 MΩ - 40 MΩ10 kΩ±(5 % + 1 digit)
DC current measurement (I=):
Measuring range: Resolution: Accuracy:
0 mA - 150 mA 0.1 mA ±(2.5 % + 3 digits)
Unsymmetrie balance at 1 MHz (LCL):
Measuring range: Resolution: Accuracy:
0 dB - 55 dB 0.1 dB ± 1.5 dB
55.1 dB - 65 dB 0.1 dB ± 3 dB
The length of the measuring leads can significantly affect the measurement. Therefore,
always use the original accessories for measuring.
Near-end crosstalk at 1 MHz (NEXT):
Measuring range: Resolution: Accuracy:
0 dB - 65 dB 0.1 dB ± 1 dB
The length of the measuring leads can significantly affect the measurement. Therefore,
always use the original accessories for measuring.
Reference conditions (calibration):
- Temperature: +23 °C to ± 5 °C
- Humidity: 50 % ± 20 %, relative, non-condensing
- Frequency of measurement quantity: 50 Hz ± 5 Hz, sine
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Intec Apparecchiature di prova
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione