8
7.Identifying the best place for installation
The IVP 8000 EX sensor has communication signal level indications with the AMT 8000 center, this will help you choose
the best installation location. Follow the procedure:
1. Once properly registered, take the sensor to the environment you wish to protect;
2. Check the position where the sensor can cover the whole environment, respecting the installation height, according to
the table in item
1.2. Detection range.
3. Once chosen, position the sensor in the exact place where it will be installed and perform a transmission through a
detection or tamper opening;
4. Observe the color that the LED will light up and check in the following table if the sensor can be installed in this location;
LED status Communication level
Green Excellent signal level (Recommended installation location)
Orange Regular signal level Not recommended location for installation (communication failure may occur)
Red No communication (Do not install on site)
Blue Intrusion detection
5. If the signal level is not excellent, reposition the sensor and perform the procedure again.
8.Installation
Once the best installation location has been identied, set the height of the sensor.
We recommend that this sensor be installed at a height of 1.8 m to 2.2 m and positioned so that the intruder performs
movements transverse to the sensor’s detection radius. It is not recommended to install the sensor tilted up or down as this
may impair the functioning of its PET function.
Check that the sensor is rmly xed and not subject to icker, in order to avoid unwanted triggering. The Articulated Bra-
cket can be used to ensure greater exibility to the installation, adapting to most scenarios and installation angles. Follow
all the mounting instructions in the manual for maximum benet.
8.1.
Anti-Sabotage
Function
The
Anti-Sabotage
function prevents the sensor from having its position changed after installation, sending a Tamper shot
to the central, thus preventing its detection eld from being changed and keeping the area always protected.
Operation
To understand how it works, see the examples below:
Examples of operation
» Example 1: describes the operation of the sensor under the following conditions:
» During the initial 15 minutes after registration;
» During the initial 15 minutes after pressing the registration key;
» Or during the Wireless Sensor Test congured on the keyboard (programming:
Enter + 52 + Enter
).
1. Register the sensor in an AMT 8000 control panel (check item
6. Registering the IVP 8000 EX sensor
).
2. With the sensor enrolled, close the front cover and keep the sensor in a xed position.
3. Change the position of the sensor (vertically or horizontally) and keep it in the modied position. Pay attention to mes-
sages on the keyboard or conguration applications.
4. Check on the keyboard if the Tamper message of the zone in which the sensor was registered will appear. The time for
sending a tamper can take up to 45 seconds.
5. The tamper will automatically reset after 1 minute, clearing the keypad message.
» Example 2: describes the operation of the sensor under the following conditions:
» 15 minutes after registration;
» 15 minutes after the registration key is pressed;
» 15 minutes after the Wireless Sensors Test congured on the keyboard (programming:
Enter + 52 + Enter
).